{"id":69136,"date":"2026-06-10T17:04:15","date_gmt":"2026-06-10T17:04:15","guid":{"rendered":"https:\/\/www.europesays.com\/ai\/69136\/"},"modified":"2026-06-10T17:04:15","modified_gmt":"2026-06-10T17:04:15","slug":"using-diesel-generators-to-power-the-ai-revolution-would-kill-hundreds-of-americans-a-year","status":"publish","type":"post","link":"https:\/\/www.europesays.com\/ai\/69136\/","title":{"rendered":"Using diesel generators to power the AI revolution would kill hundreds of Americans a\u00a0year"},"content":{"rendered":"<p>With U.S. electricity demand starting to rise quickly and expected to continue rising, largely because of the power needed for <a href=\"https:\/\/www.belfercenter.org\/research-analysis\/ai-data-centers-us-electric-grid\" rel=\"nofollow noopener\" target=\"_blank\">data centers that process artificial intelligence<\/a>, people are looking for almost any potential solution.<\/p>\n<p>And people are warning that the full projected demand may not actually develop, which could make <a href=\"https:\/\/ieefa.org\/resources\/risk-ai-driven-overbuilt-infrastructure-real\" rel=\"nofollow noopener\" target=\"_blank\">massive investments in power plants unnecessary<\/a>, raising Americans\u2019 electricity rates even more.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\" wp-image-32703\" src=\"https:\/\/www.europesays.com\/ai\/wp-content\/uploads\/2026\/06\/data-centers-are-spread-all-across-the-united-states-300x255.png\" alt=\"Data centers are spread all across the United States (Map: The Conversation, CC-BY-ND; Source: Mongird et al., 2026)\" width=\"429\" height=\"365\"  \/>Data centers are spread all across the United States (Map: The Conversation, <a href=\"https:\/\/creativecommons.org\/licenses\/by-nd\/4.0\/deed.en\" rel=\"nofollow noopener\" target=\"_blank\">CC-BY-ND<\/a>; Source: Mongird et al., 2026)<\/p>\n<p>U.S. Secretary of Energy Chris Wright is among those who have been promoting what might seem to be an attractive idea: \u201c<a href=\"https:\/\/www.eenews.net\/articles\/wright-floats-backup-generators-as-grid-fix\/\" rel=\"nofollow noopener\" target=\"_blank\">We have 35 gigawatts of backup generators<\/a> that are sitting there,\u201d he told an audience of natural gas industry leaders in December 2025. He was referring to <a href=\"https:\/\/mansfield.energy\/2025\/05\/15\/the-fuel-equation-behind-data-center-reliability\/\" rel=\"nofollow noopener\" target=\"_blank\">diesel-fired engines<\/a> at hospitals, office complexes, corporate campuses and even data centers to provide electricity if the grid goes down.<\/p>\n<p>That amount of power would be a significant step toward meeting the nation\u2019s expected energy needs, without needing new long-term investments in power plants or transmission lines. But it\u2019s also vital to know, as Wright went on to note, that \u201c<a href=\"https:\/\/www.eenews.net\/articles\/wright-floats-backup-generators-as-grid-fix\/\" rel=\"nofollow noopener\" target=\"_blank\">emissions rules or whatever<\/a>\u201d mean those generators can\u2019t just be turned on and left running when there\u2019s not a power outage or other emergency.<\/p>\n<p>As an environmental engineer who studies <a href=\"https:\/\/epp.engineering.cmu.edu\/directory\/bios\/adams-peter.html\" rel=\"nofollow noopener\" target=\"_blank\">air pollution from the energy system<\/a>, I believe this proposal is concerning. Those <a href=\"https:\/\/www.globalpwr.com\/blog\/epa-compliance-for-diesel-generators-simplified\/\" rel=\"nofollow noopener\" target=\"_blank\">emissions rules<\/a> are in place because diesel-powered generators are among the <a href=\"https:\/\/www.epa.gov\/air-emissions-factors-and-quantification\/ap-42-fifth-edition-volume-i-chapter-3-stationary-0\" rel=\"nofollow noopener\" target=\"_blank\">dirtiest sources of energy<\/a>, emitting <a href=\"https:\/\/www.epa.gov\/egrid\" rel=\"nofollow noopener\" target=\"_blank\">fine particulate matter<\/a> and <a href=\"https:\/\/www.epa.gov\/pm-pollution\/pm25-precursor-demonstration-guidance\" rel=\"nofollow noopener\" target=\"_blank\">related chemicals<\/a>. That is a pollutant whose total emissions from all sources are estimated to <a href=\"https:\/\/doi.org\/10.1021\/acs.estlett.0c00424\" rel=\"nofollow noopener\" target=\"_blank\">cause about 100,000 premature deaths every year in the U.S.<\/a> And in fact, <a href=\"https:\/\/www.globalpwr.com\/blog\/epa-compliance-for-diesel-generators-simplified\/\" rel=\"nofollow noopener\" target=\"_blank\">emissions regulations on backup generators<\/a> are less stringent than other power sources because they are intended only to run in emergency situations.<\/p>\n<p>If Wright\u2019s idea took hold, diesel fumes would pour into the nation\u2019s air, often near major metropolitan areas that <a href=\"https:\/\/www.bts.gov\/content\/air-pollution-trends-selected-metropolitan-statistical-areas\" rel=\"nofollow noopener\" target=\"_blank\">already have air pollution problems<\/a>. To see more closely what would happen, <a href=\"https:\/\/www.linkedin.com\/in\/allenj05\/\" rel=\"nofollow noopener\" target=\"_blank\">John Allen<\/a>, a research assistant at Carnegie Mellon University, and I projected the effects on public health and air quality of running backup diesel generators at data centers.<\/p>\n<p>Simulating the emissions of diesel generators<\/p>\n<p>Comprehensive data is hard to nail down about locations of data centers and which ones have how many diesel generators on site. Nobody has yet made a detailed proposal for which generators might be switched on, or for how long, so we did an exploratory analysis.<\/p>\n<p>We started with an <a href=\"https:\/\/data.msdlive.org\/records\/65g71-a4731\" rel=\"nofollow noopener\" target=\"_blank\">online database of locations of data centers<\/a>. We also found documentation suggesting there is <a href=\"https:\/\/betterdatacenterproject.com\/wp-content\/uploads\/2026\/03\/Diesel-Generators-at-Data-Centers-Status-Impacts-and-Protective-Practices.pdf\" rel=\"nofollow noopener\" target=\"_blank\">at least 35 gigawatts of diesel-powered generating capacity<\/a> at data centers across the U.S., so we allocated that amount, which Wright had mentioned, proportionally to each data center\u2019s size.<\/p>\n<p>We looked at a scenario where these generators ran continuously throughout the year, generating 310 terawatt-hours of electricity. The generators might be used less \u2013 Wright himself talked about running them for only \u201ca few hours per year.\u201d But once they\u2019re allowed to be turned on for regular power generation, people might get used to having that electricity available.<\/p>\n<p>We assumed that all diesel generators are relatively new and comply with the Environmental Protection Agency\u2019s <a href=\"https:\/\/www.epa.gov\/regulations-emissions-vehicles-and-engines\/regulations-emissions-heavy-equipment-compression\" rel=\"nofollow noopener\" target=\"_blank\">most recent and stringent standards<\/a>, which took full effect in 2015.<\/p>\n<p>We compared the air pollution created from the diesel generators with a scenario where that same amount of power \u2013 310 terawatt-hours \u2013 came from the existing mix of power plants in <a href=\"https:\/\/www.epa.gov\/egrid\" rel=\"nofollow noopener\" target=\"_blank\">regional electrical grids<\/a>. This could happen if utility companies built more generation capacity of the same types that already exist in the region or built new transmission lines to deliver more power from elsewhere.<\/p>\n<p>Because no air quality model is perfect, we used three <a href=\"https:\/\/doi.org\/10.1371\/journal.pone.0176131\" rel=\"nofollow noopener\" target=\"_blank\">different<\/a> <a href=\"https:\/\/doi.org\/10.1021\/acs.est.5b06125\" rel=\"nofollow noopener\" target=\"_blank\">computer<\/a> <a href=\"https:\/\/doi.org\/10.1038\/s43247-025-02100-y\" rel=\"nofollow noopener\" target=\"_blank\">simulations<\/a>, each of which has been published in scholarly research journals, to simulate what would happen to the diesel pollution and how people downwind would be affected.<\/p>\n<p>Diesel is dirtier<\/p>\n<p>We found that using diesel generators rather than grid electricity would cause significant amounts of fine particulate matter pollution that would be dangerous to people\u2019s health.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-32704\" src=\"https:\/\/www.theinvadingsea.com\/wp-content\/uploads\/2026\/05\/file-20260427-57-y06mo0-300x217.avif\" alt=\"A diesel generator malfunction on a hotel roof in Denver in 2015 sent black smoke into the sky. Firefighters determined there was no fire. (Andy Cross\/The Denver Post via Getty Images)\" width=\"429\" height=\"311\"  \/>\u00a0A diesel generator malfunction on a hotel roof in Denver in 2015 sent black smoke into the sky. Firefighters determined there was no fire. (<a class=\"source\" href=\"https:\/\/www.gettyimages.com\/detail\/news-photo\/thick-black-smoke-pours-out-of-a-diesel-generator-on-top-of-news-photo\/475622390\" rel=\"nofollow noopener\" target=\"_blank\">Andy Cross\/The Denver Post via Getty Images<\/a>)<\/p>\n<p>The exact results varied with each simulation and with a range of assumptions about emissions from diesel generators. But in general, we found that using backup diesel generators this way would cause about 500 more premature deaths per year in the U.S. compared with getting the same electricity from the central grid.<\/p>\n<p>In a scenario where diesel generators were somewhat dirtier than the most recent standards, one air quality model had more than 800 additional people dying prematurely each year nationwide.<\/p>\n<p>In the counties that would be hardest hit by the diesel generators\u2019 pollution, the concentrations of fine particulate matter would increase by 0.25 to 2 micrograms per cubic meter of air, depending on the location and other assumptions for our calculations. This might not sound like a lot, but <a href=\"https:\/\/www.epa.gov\/air-trends\/air-quality-design-values\" rel=\"nofollow noopener\" target=\"_blank\">most urban areas in the U.S.<\/a> already have fine particulate air pollution that\u2019s close to the <a href=\"https:\/\/www.epa.gov\/pm-pollution\/national-ambient-air-quality-standards-naaqs-pm\" rel=\"nofollow noopener\" target=\"_blank\">EPA limit of 9 micrograms per cubic meter<\/a>. Adding that much more pollution risks tipping those communities beyond federal standards.<\/p>\n<p>The <a href=\"https:\/\/www.epa.gov\/laws-regulations\/summary-clean-air-act\" rel=\"nofollow noopener\" target=\"_blank\">Clean Air Act<\/a> requires states to adjust their emissions to meet standards, so upping pollution from backup generators would require other cuts in emissions, such as at power plants and transportation.<\/p>\n<p>Inspection and maintenance challenges<\/p>\n<p>The results concern us, but reality might be even worse. We assumed that diesel generators would meet the most recent Tier 4 EPA emissions standards, but they may be older or exempt for other reasons.<\/p>\n<p>For all our simulations, we assumed inspections and maintenance would keep emissions controls functioning properly at all generators. Modern diesel particulate filters are <a href=\"https:\/\/ww2.arb.ca.gov\/diesel\/verdev\/vt\/stationary.htm\" rel=\"nofollow noopener\" target=\"_blank\">effective at reducing emissions<\/a>, though not eliminating them entirely. When those filters fail, <a href=\"https:\/\/ww2.arb.ca.gov\/sites\/default\/files\/2020-08\/dpfeval_0.pdf\" rel=\"nofollow noopener\" target=\"_blank\">emissions skyrocket<\/a>. Monitoring and maintenance at all of the generators, if they were running continuously, would be a logistical nightmare for regulators and the owners of the generators, and likely expensive as well.<\/p>\n<p>Historically, centralized power plants that have thorough on-site monitoring are the most likely to have emissions control equipment running correctly to reduce emissions verifiably. Shifting to smaller generator units in a wide range of locations creates more potential points of failure and makes it harder to figure out that something has gone wrong, and where.<\/p>\n<p>In our analysis, we compared backup diesel generators with the current electrical grid, where <a href=\"https:\/\/www.eia.gov\/tools\/faqs\/faq.php?id=427&amp;t=3\" rel=\"nofollow noopener\" target=\"_blank\">60% of generation is still from fossil fuels<\/a>. Increasing generation from renewable energy sources, such as solar panels and wind power, could help meet the rising demand for power without the additional emissions of dangerous air pollution.<img loading=\"lazy\" decoding=\"async\" style=\"border: none !important; box-shadow: none !important; margin: 0 !important; max-height: 1px !important; max-width: 1px !important; min-height: 1px !important; min-width: 1px !important; opacity: 0 !important; outline: none !important; padding: 0 !important;\" src=\"https:\/\/www.europesays.com\/ai\/wp-content\/uploads\/2026\/06\/1781111055_437_count.gif\" alt=\"The Conversation\" width=\"1\" height=\"1\"\/><\/p>\n<p><a href=\"https:\/\/theconversation.com\/profiles\/peter-adams-2658547\" rel=\"nofollow noopener\" target=\"_blank\">Peter Adams<\/a> is a professor of civil and environmental engineering, and engineering and public policy at <a href=\"https:\/\/theconversation.com\/institutions\/carnegie-mellon-university-970\" rel=\"nofollow noopener\" target=\"_blank\">Carnegie Mellon University.<\/a><\/p>\n<p>This article is republished from <a href=\"https:\/\/theconversation.com\" rel=\"nofollow noopener\" target=\"_blank\">The Conversation<\/a> under a Creative Commons license. Read the <a href=\"https:\/\/theconversation.com\/using-diesel-generators-to-power-the-ai-revolution-would-kill-hundreds-of-americans-a-year-280892\" rel=\"nofollow noopener\" target=\"_blank\">original article<\/a>. Banner photo:\u00a0Diesel generators sit outside a data center in Ashburn, Va. (<a href=\"https:\/\/www.gettyimages.com\/detail\/news-photo\/diesel-fueled-generators-sit-between-buildings-at-equinix-news-photo\/2194970695\" rel=\"nofollow noopener\" target=\"_blank\">Amanda Andrade-Rhoades for The Washington Post via Getty Images<\/a>).<\/p>\n<p>Sign up for The Invading Sea newsletter by <a href=\"https:\/\/lp.constantcontactpages.com\/su\/vIC9GhU\/theinvadingsea\" rel=\"nofollow noopener\" target=\"_blank\">visiting here<\/a>. If you are interested in submitting an opinion piece to The Invading Sea, <a href=\"https:\/\/www.theinvadingsea.com\/2026\/06\/10\/data-centers-ai-diesel-generators-air-pollution-particulate-matter-electricity-demand\/mailto:ncrabbe@fau.edu\" rel=\"nofollow noopener\" target=\"_blank\">email Editor Nathan Crabbe<\/a>.\u00a0<\/p>\n","protected":false},"excerpt":{"rendered":"With U.S. electricity demand starting to rise quickly and expected to continue rising, largely because of the power&hellip;\n","protected":false},"author":2,"featured_media":69137,"comment_status":"","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[2],"tags":[24,8432,25,38544,7949,39,34580,21306,38545,817],"class_list":["post-69136","post","type-post","status-publish","format-standard","has-post-thumbnail","category-ai","tag-ai","tag-air-pollution","tag-artificial-intelligence","tag-backup-power","tag-clean-air-act","tag-data-centers","tag-diesel-generators","tag-electricity-demand","tag-particulate-matter","tag-public-health"],"_links":{"self":[{"href":"https:\/\/www.europesays.com\/ai\/wp-json\/wp\/v2\/posts\/69136","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.europesays.com\/ai\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.europesays.com\/ai\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.europesays.com\/ai\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.europesays.com\/ai\/wp-json\/wp\/v2\/comments?post=69136"}],"version-history":[{"count":0,"href":"https:\/\/www.europesays.com\/ai\/wp-json\/wp\/v2\/posts\/69136\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.europesays.com\/ai\/wp-json\/wp\/v2\/media\/69137"}],"wp:attachment":[{"href":"https:\/\/www.europesays.com\/ai\/wp-json\/wp\/v2\/media?parent=69136"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.europesays.com\/ai\/wp-json\/wp\/v2\/categories?post=69136"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.europesays.com\/ai\/wp-json\/wp\/v2\/tags?post=69136"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}