Converting glucose into gluconate 

The catalyst converts excess glucose in the blood into gluconate. This means that some of the glucose is no longer metabolised and stored in tissue, which also helps limit the build-up of body fat. The gluconate is then excreted in the urine. 

The catalyst is controlled wirelessly through a closed-loop system. A standard glucose sensor, like those commonly worn on the upper arm by people with diabetes, continuously monitors glucose levels in the tissue. If blood sugar rises too high after a meal, the sensor sends a signal via Bluetooth to a smartphone or smartwatch. The smart device then activates the catalyst, which uses electrical energy to convert the glucose. Once glucose levels have fallen to the desired level, the device switches itself off automatically, protecting patients from dangerously low blood sugar. 

Successfully tested in mice 

In a laboratory experiment, Fussenegger’s team tested the system in a reservoir holding five litres of a glucose-containing nutrient solution – roughly the volume of blood in the human body. This showed that the catalyst was capable of converting glucose in this volume of solution. The researchers also tested the system in diabetic mice and found that the animals’ blood sugar could be precisely regulated. The mice lost weight, the implant was well tolerated and it operated reliably during a six-week period. “The system operates at a very low voltage, and our experiments showed no evidence of tissue damage from either electrical or thermal effects,” says Fussenegger. The team has not yet tested the device on humans. 

Paradigm shift: from conventional drugs to an electronic device 

Fussenegger sees the approach as a paradigm shift away from conventional drugs and towards scalable, electronically controlled treatments that can be integrated into digital environments such as the Internet of Things. “ 

For decades, we have treated diabetes by telling the body how to manage glucose. We are now showing that we can take control of glucose directly, using electronics rather than drugs,” he says. “And the catalyst only activates when glucose levels are too high.” 

The team now plans to develop the system into a medical device. Because the glucose-lowering mechanism itself works without cells or enzymes, technical development could be more straightforward. 

Another advantage is that the components needed to build such a device, including external control and wireless power transmission devices, have already been developed and are commercially available.