{"id":208191,"date":"2026-11-18T16:37:13","date_gmt":"2026-11-18T16:37:13","guid":{"rendered":"https:\/\/www.europesays.com\/dk\/208191\/"},"modified":"2026-11-18T16:37:13","modified_gmt":"2026-11-18T16:37:13","slug":"denmark-buried-800-m-of-geothermal-pipes-beneath-a-50-m-road-over-20-months-the-system-delivered-98-mwh-of-heat-at-a-cop-of-3-1-while-the-roadbed-was-designed-to-hold-120-m%c2%b3-of-rainwater","status":"publish","type":"post","link":"https:\/\/www.europesays.com\/dk\/208191\/","title":{"rendered":"Denmark buried 800 m of geothermal pipes beneath a 50 m road; over 20 months, the system delivered 98 MWh of heat at a COP of 3.1, while the roadbed was designed to hold 120 m\u00b3 of rainwater |"},"content":{"rendered":"<p> <img src=\"https:\/\/www.europesays.com\/dk\/wp-content\/uploads\/2026\/11\/representative-ai-image-illustrating-geothermal-heat-exchange-pipes-and-a-rainwater-storage-system-i.png\" alt=\"Denmark installed 800 m of geothermal pipes beneath a 50 m road; during monitoring, the system supplied 98 MWh of heat at a COP of 3.1, while the roadbed was designed to store up to 120 m\u00b3 of rainwater\" title=\"Representative AI image illustrating geothermal heat-exchange pipes and a rainwater-storage system installed beneath a road in Denmark. Image Credits: ChatGPT.\" decoding=\"async\" fetchpriority=\"high\"\/>Representative AI image illustrating geothermal heat-exchange pipes and a rainwater-storage system installed beneath a road in Denmark. Image Credits: ChatGPT. Roads are designed to carry traffic, but a new scheme in Denmark demonstrates how they can serve another purpose. A rainwater collection tank and geothermal heat scheme combine to transform a new road into a source of renewable heat while also assisting the city to cope with higher rainfall. It&#8217;s an idea that could bring new uses to old city structures.According to a 2020 study published in <a href=\"https:\/\/www.mdpi.com\/2073-4441\/14\/4\/666\" rel=\"noopener nofollow noreferrer\" styleobj=\"[object Object]\" class=\"\" target=\"\" commonstate=\"[object Object]\" frmappuse=\"1\">Water<\/a>, the Climate Road Project was developed in Hedensted, Denmark, to show how road construction can support both climate adaptation and renewable energy generation. The road was constructed with 800 m of geothermal piping underneath it and a perforated drain to collect and store up to 120 m\u00b3 of rainwater. The 50m road shows that the heat stored in the system was contributing 98MWh of heat to a local kindergarten, with a coefficient of performance (COP) of 3.1.How Denmark developed the multifunctional road The parking lot is 50m long by 8m wide and 1m deep. It consists of two parking lanes of 25 m of permeable asphalt and 25 m of regular asphalt. Rainwater makes its way into the system via permeable areas as part of the drainage grates incorporated into the system, where it pools in gravel layers rather than being drained into the municipal sewer system immediately. The pipes were installed just below the asphalt, about a meter beneath the surface, and two were placed at a depth of 50 cm.The pipes were embedded in bedding of carefully selected gravel, which acted to protect the pipes and enabled the transfer of heat between the pipe and the earth. The pipe circuit was connected to a ground-source heat pump that provided hot water to the kindergarten&#8217;s domestic hot water and space heating. This configuration enabled the roadbed to act as both a heat collector and a holding area for temporary stored rainwater. The project was monitored from May 2019 to December 2020 to evaluate its performance in changing weather and rainfall conditions.How the road generated heat and managed rainwaterHeat was transferred from the roadbed into the pipes via a heat pump that increased its temperature so it could be used to heat the kindergarten. The heat pump used some electricity to operate. This needed to be weighed against the heat it was able to supply for the same amount of energy, and this is done using the coefficient of performance. For example, a COP of 3.1 delivers approximately 3.1 units of heat for every unit of electricity used. As per the findings published in Water, the Climate Road generated a total of 98 megawatt-hours of heat between May 2019 and December 2020, with an average of 1,654 mm of rainfall during the two-year monitoring period, and a capacity of 120 cubic metres to retain rainwater and delay its release into the surrounding area in the system.They looked at 61 rainfall events and calculated that water took anywhere between 10 and 130 minutes to reach the system, or an average of 35 minutes. This means the amount of stormwater that enters the city system during heavy rain was reduced. Research published in <a href=\"https:\/\/www.mdpi.com\/1996-1073\/15\/12\/4505\" rel=\"noopener nofollow noreferrer\" styleobj=\"[object Object]\" class=\"\" target=\"\" commonstate=\"[object Object]\" frmappuse=\"1\">Energies<\/a> in 2022 also investigated the simultaneous development of ground-source heating and sustainable urban drainage in the roadbed. The exploration examined the possibility of a gravel-formed matrix serving as both a rainwater pond and aheat-exchange interface.<img decoding=\"async\" alt=\"Road resurfacing work underway on a Copenhagen street in Denmark, illustrating the road infrastructure involved in urban geothermal and rainwater-management projects.\" msid=\"135928493\" imgsize=\"165874\" resizemode=\"4\" width=\"\" title=\"Road resurfacing work is underway on a Copenhagen street in Denmark, illustrating the road infrastructure involved in urban geothermal and rainwater-management projects. Image Credits: Wikimedia Commons.\" placeholdersrc=\"https:\/\/static.toiimg.com\/photo\/83033472.cms\" offsetvertical=\"0\" placeholdermsid=\"47529300\" type=\"thumb\" class=\"\" src=\"https:\/\/www.europesays.com\/dk\/wp-content\/uploads\/2026\/11\/road-resurfacing-work-underway-on-a-copenhagen-street-in-denmark-illustrating-the-road-infrastructur.png\" data-api-prerender=\"true\"\/><\/p>\n<p>Road resurfacing work is underway on a Copenhagen street in Denmark, illustrating the road infrastructure involved in urban geothermal and rainwater-management projects. Image Credits: Wikimedia Commons.<\/p>\n<p>What the project revealed about future road constructionHowever, the Climate Road also revealed several problems that need to be solved in order for the system to be implemented in the future. During the trial, one of the geothermal pipes started to leak brine in November 2019. It was removed, which meant the effective length of the heat exchangers was reduced from 800 m to 600 m. The team also discovered that brine temperature remained below zero degrees Celsius for a long time. As it was below Danish regulations, the heat pump was disconnected from the Climate Road in January 2020 and reconnected to the original ground heat exchangers. The study found that the heat output that was produced would not be maintained long-term at this level.Rainwater management was another maintenance issue over time. Sediment and debris settled in the pores of the permeable asphalt, clogging it and diminishing the paved surface&#8217;s capacity to absorb water. Regular cleaning with a high-pressure water jet helped recover some of the capacity to infiltrate water, but not all. Still, the project exemplifies how a short stretch of a city road can serve more than just one function of transporting traffic. Through the integration of new water collection and interim water storage supplies, it offers an alternative paradigm for the design of infrastructure in contexts where increasing rainfall and energy requirements intersect.<\/p>\n","protected":false},"excerpt":{"rendered":"Representative AI image illustrating geothermal heat-exchange pipes and a rainwater-storage system installed beneath a road in Denmark. Image&hellip;\n","protected":false},"author":2,"featured_media":208192,"comment_status":"","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"footnotes":"","_share_on_mastodon":"0"},"categories":[2],"tags":[77589,27,26,50390,85253,928,67702],"class_list":["post-208191","post","type-post","status-publish","format-standard","has-post-thumbnail","category-denmark","tag-climate-adaptation","tag-danmark","tag-denmark","tag-geothermal-heating","tag-rainwater-management","tag-renewable-energy","tag-sustainable-infrastructure"],"share_on_mastodon":{"url":"https:\/\/pubeurope.com\/@dk\/117638427356572373","error":""},"_links":{"self":[{"href":"https:\/\/www.europesays.com\/dk\/wp-json\/wp\/v2\/posts\/208191","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.europesays.com\/dk\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.europesays.com\/dk\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.europesays.com\/dk\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.europesays.com\/dk\/wp-json\/wp\/v2\/comments?post=208191"}],"version-history":[{"count":0,"href":"https:\/\/www.europesays.com\/dk\/wp-json\/wp\/v2\/posts\/208191\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.europesays.com\/dk\/wp-json\/wp\/v2\/media\/208192"}],"wp:attachment":[{"href":"https:\/\/www.europesays.com\/dk\/wp-json\/wp\/v2\/media?parent=208191"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.europesays.com\/dk\/wp-json\/wp\/v2\/categories?post=208191"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.europesays.com\/dk\/wp-json\/wp\/v2\/tags?post=208191"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}