Consider an AI-system screening patients for cardiac conditions. For months, it has operated reliably, improving diagnostic accuracy and efficiency. Suddenly, a malfunction causes it to miss heart murmurs, producing erroneous outputs, ultimately posing risks to patient health.
Human oversight is often proposed as a safeguard against such risks1,2. Humans are expected to serve as a “safety net” by detecting inaccurate outputs and malfunctions, whether caused by technical errors, data drift, faulty inputs, or cyberattacks3. While research has examined how AI can augment human decision-making4, less attention has been directed to how reliably humans can prevent the consequences of system malfunctions.
Detecting system malfunctions is demanding, requiring sustained vigilance and cognitive engagement, especially when a system has previously performed flawlessly5. Automation bias may lead physicians to over-rely on AI recommendations, using AI “as a heuristic replacement for vigilant information-seeking and processing”6. Moreover, AI outputs can serve as cognitive anchors, inducing confirmation bias toward the initially presented outputs2,7, thereby reducing cognitive engagement and increasing the likelihood of adopting rather than questioning AI recommendations8,9,10,11. To counter such detrimental effects, cognitive forcing techniques have been proposed to maintain active engagement2,5,12, e.g., by requiring an independent assessment before revealing AI recommendations12. Such cognitive forcing requires physicians to actively process clinical data, develop hypotheses, and seek relevant evidence2,9. AI recommendations should then update rather than anchor physicians’ initial assessments2.
This study examined whether and when physicians can detect AI malfunctions, intervene appropriately, and whether cognitive forcing strategies can facilitate these tasks. We hypothesized that physicians who make an independent classification before, compared to after, receiving the AI recommendation would better detect and override inaccurate AI recommendations, and adjust their trust in the AI-system accordingly5,12,13. We additionally examined how this intervention affects physicians’ confidence in their own classifications9,14.
We conducted a randomized-controlled experiment using a mixed 2×4 design in the context of AI-assisted cardiac auscultation. Forty-eight physicians were randomly assigned to either an AI-First or AI-Second condition. Participants were informed about the AI’s training data and validation performance (96% accuracy with 97% sensitivity, 89% specificity). Each participant classified 40 digitally recorded heart sounds, presented across four blocks, as either normal or abnormal. To simulate system malfunction, system reliability declined stepwise across blocks (90%, 60%, 50%, 0%). In the final block, auditory and visual cues were deliberately mismatched to provide an additional signal of severe system malfunction15. The AI-Second condition implemented the cognitive forcing technique: Participants first provided an unassisted classification and confidence rating, which they could revise after receiving the AI recommendation. The AI-First condition received the AI recommendation before providing their classification and confidence rating. In both groups, participants rated their trust in the system after every fifth trial.
Figure 1 displays participants’ performance, confidence, and trust scores. Table 1 displays ANOVA results. As predicted, the AI-assisted diagnostic performance declined alongside system reliability from MT1 = 81.45% (SDT1 = 11.48%) to MT4 = 58.33% (SDT4 = 25.29%). The AI-assisted performance at T1 was lower than the AI-system reliability (90%), whereas in T2-T4 it was higher than the AI-system reliability, but lower than human unassisted performance. Overall, cognitive forcing did not improve diagnostic performance: The Group×Block interaction for performance was significant, but contrary to our hypothesis, at T4 the AI-First group (MT4|AI-First = 64.58%, SDT4|AI-First = 22.65%) outperformed the AI-Second group (MT4|AI-Second = 52.08%, SDT4|AI-Second = 26.70%).
Fig. 1: Study results.
Diagnostic performance (A), diagnostic confidence (B), and trust (C) across four blocks with decreasing system reliability for the AI-First (orange; n = 24) and AI-Second (turquoise; n = 24) groups. Dashed turquoise lines indicate participants’ unassisted performance and confidence prior to receiving the AI recommendations (AI-Second condition only). Error bars indicate standard errors.
Table 1 ANOVA results, i.e., main effects of block (with varying reliability) and group, as well as their interaction for diagnostic performance, diagnostic confidence, and trust
In both groups, participants’ confidence after the AI recommendation dropped significantly across blocks from MT1 = 3.39 (SDT1 = 0.34) to MT4 = 3.04 (SDT4 = 0.50); and we additionally found a significant Group×Block interaction. In the AI-Second group, confidence before the AI recommendation declined across blocks, although unassisted performance did not decline (dashed lines in Fig. 1A, B and Table 1). Trust declined in both groups from MT1 = 3.40 (SDT1 = 0.91) to MT4 = 3.03 (SDT4 = 0.98). There were no significant group or interaction effects for trust. After the experiment, only 12.5% (three per group) reported noticing declining system reliability, and even when explicitly asked for changes in the system, only 37.5% (AI-First: 41.7%; AI-Second: 33.3%) reported noticing reduced reliability.
Our study examined whether physicians can detect AI malfunctions and intervene effectively, and whether cognitive forcing supports these central goals of human oversight. It revealed three important insights. First, in the high-reliability block (T1), combined human-AI performance was lower than system reliability (cf. ref. 4). Second, when system reliability declined, combined human-AI performance was higher than system reliability, indicating physicians’ partial ability to detect and override inaccurate AI recommendations. However, under low system reliability, combined human-AI performance also declined below the unassisted human baseline. Only a minority of participants reported noticing system malfunctions. Third, cognitive forcing did not improve human-AI performance. Together with prior evidence on erroneous AI support in medical decision-making10,16, these findings challenge the assumption that physicians can reliably detect and correct erroneous AI outputs, and they question the supporting effect of cognitive forcing.
Automation bias6 may have been one reason for physicians adopting inaccurate system recommendations. However, to understand why physicians did not sufficiently override the AI even after forming an independent assessment, the observed relationship between diagnostic confidence and trust in AI11,17 may provide important insights. While baseline performance remained stable in the AI-Second group (dashed line in Fig. 1A), initial diagnostic confidence declined faster (T1 > T3) than trust in the AI (T1 > T4) under decreasing reliability. The AI’s reported 96% accuracy may have fostered overestimations of system reliability18 and increased trust and reliance11, leading physicians to question their own judgment rather than the AI. Even when additional signals of system malfunction were present (T4), participants did not reliably override the AI system. These exploratory findings tentatively suggest that AI outputs may possess high perceived authority, even when physicians independently process diagnostic information before receiving AI recommendations5,6,19. However, these interpretations require further validation.
Several aspects of our experimental setup limit generalizability of our results. Although physician experience did not affect our results, 38% of participants were physicians in training. Additionally, the study was conducted in a controlled lab environment focusing on an isolated diagnostic subtask without physician-patient interaction or access to additional clinical information (e.g., vital signs, general patient presentation). Our manipulation of system malfunction included a rapid continuous decline in system reliability resulting in 0% accuracy and desynchronized auditory and visual cues. Consequently, fluctuations in reliability were not captured, order effects cannot be excluded, and we cannot conclusively tell which aspect of the system malfunction (i.e., reliability decline or desynchronization) mainly yielded the results pattern at T4. In clinical practice, system malfunctions might be more heterogeneous, e.g., more subtle or fluctuating, and real-world factors, such as fatigue, competing demands, and time pressure, likely make oversight of AI even more challenging5,20. Furthermore, prolonged reliance on highly accurate AI systems may increase trust5 while eroding manual diagnostic skills and reducing diagnostic confidence21.
For future research and practice, ensuring effective human oversight2,22 requires clearly defined success criteria. Human oversight may be considered successful if human-AI performance either (1) exceeds AI performance, or (2) does not fall below unassisted human performance. Regarding (1), our data suggest that physicians may struggle when interacting with highly reliable systems, where human involvement can reduce AI-only performance (T1, cf. refs. 4,20). Regarding (2), although physicians mitigated some negative effects of declining system reliability, low-reliability AI can deteriorate outcomes below unassisted human performance (T2-T4, cf. ref. 4).
In our experiment, cognitive forcing did not improve human oversight effectiveness. Nevertheless, further research in realistic settings is necessary to better understand cognitive-forcing effects, particularly under conditions of multiple task demands, access to additional patient information, other AI use cases (e.g., image classification, treatment planning), or dedicated training in which oversight roles are clearly specified. Beyond performance, additional outcomes should be considered. For instance, outsourcing tasks to AI may contribute to deskilling21, whereas requiring independent assessments (as in the cognitive forcing condition) may help preserve diagnostic skills, despite increasing diagnostic time. These trade-offs should be considered when designing human oversight workflows.
Since our results suggest that AI-system malfunctions may be difficult for physicians to detect, effective human oversight may require additional action at the system and organizational levels22. AI systems should provide relevant cues to facilitate monitoring and error detection, such as uncertainty indicators or explanations23. At the organizational level, accountability may need to be shared with stakeholders such as AI deployers (e.g., hospitals) and providers (e.g., developers)24. Compared to physicians who treat patients under time pressure, these actors may be better positioned to detect system biases and malfunctions at scale by using monitoring tools that can track shifts in prevalence and subgroup distributions. Combined with physicians’ informed clinical input and transparent system design, such structures may form a more robust safety net against AI malfunctions.
To conclude, our study provides initial evidence that human oversight alone may be insufficient to reliably detect system malfunctions in AI-assisted cardiac auscultation. Despite their expertise, physicians often failed to detect declining system reliability, even with additional evidence for system malfunctions (i.e., desynchronization) and when employing cognitive forcing techniques. Starting with a clear definition of oversight goals, future research should examine how physician-, system-, and organizational-level factors contribute to effective oversight in clinical workflows.