{"id":115297,"date":"2025-10-11T10:23:15","date_gmt":"2025-10-11T10:23:15","guid":{"rendered":"https:\/\/www.europesays.com\/ie\/115297\/"},"modified":"2025-10-11T10:23:15","modified_gmt":"2025-10-11T10:23:15","slug":"leveraging-body-dielectric-polarization-for-ambient-electromagnetic-energy-recovery-via-e-textile","status":"publish","type":"post","link":"https:\/\/www.europesays.com\/ie\/115297\/","title":{"rendered":"Leveraging body dielectric polarization for ambient electromagnetic energy recovery via e-textile"},"content":{"rendered":"<p>Concept of body dielectric polarization-enabled body area networks<\/p>\n<p>Textile-based body area networks (BAN) require multiple sensors and wireless transmission modules embedded in clothing or on the body to enable real-time monitoring and interaction<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 35\" title=\"Niu, S. et al. A wireless body area sensor network based on stretchable passive tags. Nat. Electron. 2, 361&#x2013;368 (2019).\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#ref-CR35\" id=\"ref-link-section-d117199054e523\" rel=\"nofollow noopener\" target=\"_blank\">35<\/a>. However, this setup necessitates separate power supply nodes or complex distributed electrode designs, which conflict with the vision of smart clothing: wireless, battery-free, comfortable, and washable. In the everyday environment, power transmission lines and high-power electrical appliances (e.g., personal computers, air conditioners) generate stray EM fields, inadvertently radiating significant EM energy into the surroundings (Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#Fig1\" rel=\"nofollow noopener\" target=\"_blank\">1a<\/a>), which in turn can be a readily available energy source for the BAN. These leaked EM\u00a0signals, resembling power-frequency noise, are primarily low-frequency (50\/60\u2009Hz), correspondingly long wavelength, and exhibit\u00a0weak parasitic coupling<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 30\" title=\"Li, J., Dong, Y., Park, J. H. &amp; Yoo, J. Body-coupled power transmission and energy harvesting. Nat. Electron. 4, 530&#x2013;538 (2021).\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#ref-CR30\" id=\"ref-link-section-d117199054e530\" rel=\"nofollow noopener\" target=\"_blank\">30<\/a>. Therefore, during the propagation of these low-frequency signals,\u00a0both the energy loss caused by parasitic capacitance and the signal reflection effect will be significantly reduced.<\/p>\n<p><b id=\"Fig1\" class=\"c-article-section__figure-caption\" data-test=\"figure-caption-text\">Fig. 1: Concept of body dielectric polarization-enabled body area networks.<\/b><a class=\"c-article-section__figure-link\" data-test=\"img-link\" data-track=\"click\" data-track-label=\"image\" data-track-action=\"view figure\" href=\"https:\/\/www.nature.com\/articles\/s41467-025-64053-2\/figures\/1\" rel=\"nofollow noopener\" target=\"_blank\"><img decoding=\"async\" aria-describedby=\"Fig1\" src=\"https:\/\/www.europesays.com\/ie\/wp-content\/uploads\/2025\/10\/41467_2025_64053_Fig1_HTML.png\" alt=\"figure 1\" loading=\"lazy\" width=\"685\" height=\"722\"\/><\/a><\/p>\n<p><b>a<\/b> Low-frequency EM energy dissipated by electronic equipment into the surrounding environment, including the human body, is a readily available source of energy to power wearable devices that are part of BAN. <b>b<\/b> Body dielectric polarization-enabled EM energy recovery to power the BAN. The illustration shows schematically how the ambient EM fields induce charge on the human body surface and how these effects can be used to generate electric current by PolaTex. <b>c<\/b> COMSOL simulation of voltage potential for air and human body. <b>d<\/b> A COMSOL simulation of the electric field for air and the human body. <b>e<\/b> COMSOL simulated potential curves showing the dissipation of energy of a 100\u2009V transmitter in air, and at 30\u2009cm from distance a human body. <b>f<\/b> A power spectrum of recovered EM energy under air and human body dielectric polarization conditions. The signal is measured directly from the daily typing office process without additional EM emission sources. Similar results were observed in three measurements. <b>g<\/b> Digital photos of the PolaTex powering an electronic watch through wireless power generation by recovery of energy emitted by the laptop.<\/p>\n<p>Here, we propose a textile electronic device utilizing the body dielectric polarization mechanism for ambient EM energy recovery (Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#Fig1\" rel=\"nofollow noopener\" target=\"_blank\">1a<\/a>, b). This electronic textile consists of three layers: a Leica cotton textile substrate, a conductive coating and a low impedance hydrogel layer. By placing the electronic textile on the surface of human skin, the EM energy can be automatically recovered from the environment through the human body and transmitted to the textile. The EM energy recovery process includes three steps: (1) the ambient freely dissipated EM field creates a capacitive effect between the air and the human body, enabling charge accumulation; (2) the electric field partially polarizes ions and water molecules in the human body; (3) the textile induces a polarized electric field, recovering the energy from these charging effects to power the BAN. Through this polarization mechanism, the dissipated EM energy is continuously recovered by the human body and transmitted to a useful load via conductive textile on the body surface. As a result, electric energy can be directly obtained from the human body surface at the necessary anatomical site corresponding to a required BAN node position.<\/p>\n<p>COMSOL simulations (Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#Fig1\" rel=\"nofollow noopener\" target=\"_blank\">1c, d<\/a>, Supplementary Figs.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">1<\/a>, <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">2<\/a> and Supplementary Note\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">2<\/a>) compare the electric field distribution in air and near the human body. Due to the relatively high dielectric constant of the human body (\u03b5\u2009\u2248\u2009106 at 50\u2009Hz)<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 33\" title=\"Gabriel, S., Lau, R. W. &amp; Gabriel, C. The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. Phys. Med. Biol. 41, 2251&#x2013;2269 (1996).\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#ref-CR33\" id=\"ref-link-section-d117199054e599\" rel=\"nofollow noopener\" target=\"_blank\">33<\/a>, and conductivity (\u03c3\u2009\u2248\u20090.1\u2009S\u2009m\u2212\u00b9), ambient EM field energy is concentrated at the body rather than dissipating in air, creating a measurable surface potential. For a 100\u2009V transmitter, the voltage attenuates significantly within the 0\u201330\u2009cm of air and continues to decrease with further distance. However, simulations show that if a human body is placed 30\u2009cm from the transmitter, the decrease\u00a0of voltage with distance slows significantly as it reaches the body surface (Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#Fig1\" rel=\"nofollow noopener\" target=\"_blank\">1e<\/a>). At 100\u2009cm from the transmitter, the body still retains a surface potential of approximately 1\u2009V, while the potential in the air, in the case where no human is present, approaches zero. As shown in Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#Fig1\" rel=\"nofollow noopener\" target=\"_blank\">1f<\/a>, in a typical office environment, we measured that the PolaTex can recover up to 10.01\u2009dBm of ambient EM energy (50\u2009Hz), while a suspended pair of electrodes (without body dielectric polarization effect) can only recover \u221230.63\u2009dBm of energy (Supplementary Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">3<\/a>). This effect can be harnessed to power small electronic devices, provided a well-conducting human-body compliant textile is used to transduce the energy harvested. For example, in this work, we demonstrate that the human body could directly power a wearable electronic watch in real-time without relying on batteries, just by recovering the EM energy emitted into the environment by an ordinary laptop (Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#Fig2\" rel=\"nofollow noopener\" target=\"_blank\">2g<\/a>). Details on the construction and operational principles of the PolaTex are provided further in the article.<\/p>\n<p><b id=\"Fig2\" class=\"c-article-section__figure-caption\" data-test=\"figure-caption-text\">Fig. 2: Principle of body dielectric polarization-enabled EM energy recovery.<\/b><a class=\"c-article-section__figure-link\" data-test=\"img-link\" data-track=\"click\" data-track-label=\"image\" data-track-action=\"view figure\" href=\"https:\/\/www.nature.com\/articles\/s41467-025-64053-2\/figures\/2\" rel=\"nofollow noopener\" target=\"_blank\"><img decoding=\"async\" aria-describedby=\"Fig2\" src=\"https:\/\/www.europesays.com\/ie\/wp-content\/uploads\/2025\/10\/41467_2025_64053_Fig2_HTML.png\" alt=\"figure 2\" loading=\"lazy\" width=\"685\" height=\"663\"\/><\/a><\/p>\n<p><b>a<\/b> A schematic diagram illustrating the interaction of the human body with the electric field, leading to polarized charges over the Gaussian surface of the human body. <b>b<\/b> Space charge polarization and dipole polarization lead to changes in the absolute permittivity of different dielectric materials at different frequencies. <b>c<\/b> Polar water molecules are deflected by an electric field. The same results were obtained in two independent tests. <b>d<\/b> Non-polar pentane molecules do not respond to electric fields. <b>e<\/b> The effect of the polarity index of the media on EM energy recovery. <b>f<\/b> Migration of charged ions under the action of an electric field results in space charge polarization. <b>g<\/b> Potential of aqueous solutions with different NaCl concentrations on EM energy recovery. <b>h<\/b> Dependence of recovered energy voltage and power as a function of exposed Gaussian surface area in the EM environment. Changing the bottom area of the reagent bottle to adjust the EM exposure area.<\/p>\n<p>Principle of body dielectric polarization-enabled EM energy recovery<\/p>\n<p>Why the human body allows for the recovery of the dissipated EM energy through polarization can be explained by Gauss\u2019s law in dielectrics. As illustrated in Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#Fig2\" rel=\"nofollow noopener\" target=\"_blank\">2a<\/a>, when radiated EM energy encounters the human body, it is equivalent to an electric displacement vector passing through the local closed Gaussian surface formed by the human body (body Gaussian surface). Then, the carrier inside the human body (containing water molecules as well as ions) will be polarized in the electrical field. Neglecting the effects of skin interface impedance, the bound charge (polarization charge) induced on the body surface can be expressed as:<\/p>\n<p>$${Q}_{i}=\\oint \\left({\\varepsilon }_{r}-1\\right){{\\, \\cdot \\, }}{\\varepsilon }_{0}{{ \\, \\cdot \\, }}E \\cdot {{{\\rm{\\cdot }}}}{dA}$$<\/p>\n<p>where \u03b5r is the dielectric constant of the human body; \u03b50 is the vacuum dielectric constant; E is the intensity of the electric field part of the EM field; A is the surface area of the body exposed to the EM field. Dry air, the relative dielectric constant of which is approximately 1, cannot sustain polarization, resulting in an induced charge density of zero. In contrast, the human body, with a relative dielectric constant up to 106 at 50\u2009Hz<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 33\" title=\"Gabriel, S., Lau, R. W. &amp; Gabriel, C. The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. Phys. Med. Biol. 41, 2251&#x2013;2269 (1996).\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#ref-CR33\" id=\"ref-link-section-d117199054e788\" rel=\"nofollow noopener\" target=\"_blank\">33<\/a>, can convert a significant portion of EM energy as polarization energy, which can then be transduced into usable current by the electrode of the current collector. This polarization occurs in two primary forms: (1) space charge polarization of ions<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 36\" title=\"Sawada, A. Internal electric fields of electrolytic solutions induced by space-charge polarization. J. Appl. Phys. 100, 074103 (2006).\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#ref-CR36\" id=\"ref-link-section-d117199054e792\" rel=\"nofollow noopener\" target=\"_blank\">36<\/a> and (2) dipole polarization of water molecules<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 37\" title=\"Yang, W. et al. Body-coupled luminescent fibers enable wireless visual sensing of contacting media. Matter 7, 4309&#x2013;4318 (2024).\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#ref-CR37\" id=\"ref-link-section-d117199054e796\" rel=\"nofollow noopener\" target=\"_blank\">37<\/a>,<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 38\" title=\"Gubskaya, A. V. &amp; Kusalik, P. G. The total molecular dipole moment for liquid water. J. Chem. Phys. 117, 5290&#x2013;5302 (2002).\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#ref-CR38\" id=\"ref-link-section-d117199054e799\" rel=\"nofollow noopener\" target=\"_blank\">38<\/a>(Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#Fig2\" rel=\"nofollow noopener\" target=\"_blank\">2a<\/a>).<\/p>\n<p>In order to investigate the effect of the medium polarity on the ambient EM energy recovery, we first measured the absolute permittivity of various materials in the low-frequency range (4 Hz\u20138\u2009MHz). Among these were dry air, pentane (a non-polar liquid), ultrapure water (a polar liquid), and 1\u2009M NaCl aqueous solution (Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#Fig2\" rel=\"nofollow noopener\" target=\"_blank\">2b<\/a>). Dry air and non-polar liquids exhibited minimal polarization and had the lowest absolute permittivity. In contrast, ultrapure water and ionic solutions displayed significantly higher absolute permittivity due to dipole polarization and space charge polarization. The high ion concentration in the ionic solution further enhanced space charge polarization. However, this effect diminished at higher frequencies due to ionic relaxation, as rapid electric field oscillations restricted ion migration.<\/p>\n<p>As shown in Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#Fig2\" rel=\"nofollow noopener\" target=\"_blank\">2c, d<\/a>, dipole polarization is primarily determined by the total dipole moment of the dielectric molecules. For instance, water molecules (Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#Fig2\" rel=\"nofollow noopener\" target=\"_blank\">2c<\/a>) have an asymmetric structure, leading to a non-zero\u00a0net dipole moment. When exposed to an electric field, these molecules align with the field. Non-polar molecules such as pentane (Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#Fig2\" rel=\"nofollow noopener\" target=\"_blank\">2d<\/a>), which have a symmetrical structure and no intrinsic dipole moment, do not react much with low-power low-frequency electric fields. To evaluate how molecular polarity affects EM energy recovery, we compared solvents with different polarity index (Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#Fig2\" rel=\"nofollow noopener\" target=\"_blank\">2e<\/a>). We placed a reagent bottle containing a solvent on the laptop and inserted the oscilloscope probe into the solution to test the voltage signal (Supplementary Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">4<\/a> and Supplementary Movie\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM4\" rel=\"nofollow noopener\" target=\"_blank\">1<\/a>). The results showed a positive correlation between a solvent\u2019s polarity index, dielectric constant, and the recovery voltage (Supplementary Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">5<\/a>). Additionally, introducing NaCl at varying concentrations into ultrapure water (Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#Fig2\" rel=\"nofollow noopener\" target=\"_blank\">2f<\/a> and Supplementary Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">6<\/a>) further increased the recovered voltage. Moreover, as the EM exposure area expanded, both the voltage and power of the recovered energy increased. Notably, even at small areas exposed to the EM fields (ca. 120\u2009cm\u00b2, which roughly corresponds to the body area of a small mammal), quite a lot of energy, around 5\u2009dBm, is being recovered, and even more for an exposure area comparable to the human body (Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#Fig2\" rel=\"nofollow noopener\" target=\"_blank\">2h<\/a> and Supplementary Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">7<\/a>).<\/p>\n<p>Mechanical and electrical performance of body dielectric polarization-enabled textiles<\/p>\n<p>Balancing electrical performance and wearable comfortability is crucial for flexible energy textiles. In order to reduce the interfacial impedance of the textile electrode while maintaining its good air permeability, we used air spraying to controllably deposit water-retaining hydrogel on the surface of PEDOT: PSS textile (Supplementary Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">8<\/a> and Supplementary Movie\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM5\" rel=\"nofollow noopener\" target=\"_blank\">2<\/a>). First, PEDOT: PSS was impregnated onto the cotton surface, imparting electronic conductivity to the textile (Supplementary Figs.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">9<\/a>, <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">10<\/a>). Second, a gelatin-based hydrogel layer was deposited on the PEDOT: PSS-treated cotton via air-spraying to reduce the skin-electrode interface impedance (Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#Fig3\" rel=\"nofollow noopener\" target=\"_blank\">3a<\/a> and Supplementary Figs.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">10<\/a>\u2212<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">13<\/a>). By controlling the air-spraying and application parameters, we could make sure that some pores of the textile remain intact in the uncovered regions, making sure that the Lycra cotton maintains its breathability (Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#Fig3\" rel=\"nofollow noopener\" target=\"_blank\">3b<\/a> and Supplementary Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">11c<\/a>). Then, we soaked the hydrogel electrodes in ammonium sulfate solution to further improve the mechanical properties and conductivity of the hydrogel interface based ion exchange<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 39\" title=\"He, Q., Huang, Y. &amp; Wang, S. Hofmeister effect-assisted one step fabrication of ductile and strong gelatin hydrogels. Adv. Funct. Mater. 28, 1705069 (2017).\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#ref-CR39\" id=\"ref-link-section-d117199054e886\" rel=\"nofollow noopener\" target=\"_blank\">39<\/a>. In the air-permeability test (Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#Fig3\" rel=\"nofollow noopener\" target=\"_blank\">3c<\/a>), it was observed that the breathability of the textile remains largely unchanged before (~286\u2009mm\u2009s\u22121) and after (~243\u2009mm\u2009s\u22121) the hydrogel addition. We characterized the washability of PolaTex. After 10 washing cycles, the hydrogel layer on its surface remained well adhered to the textile substrate, and the electrical signal exhibited no significant attenuation (Supplementary Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">14<\/a>). We also added different proportions of glycerol to improve its water retention, so that it can work stably within 2\u2009~\u20093 days (Supplementary Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">11d<\/a>). After PolaTex loses water, it can be restored to its initial state by soaking it in an aqueous solution for half an hour (Supplementary Figs.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">15<\/a>, <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">16<\/a>). The PolaTex also showed stable elastic behavior in the stretching tests from the original length to 50% strain (Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#Fig3\" rel=\"nofollow noopener\" target=\"_blank\">3d<\/a> and Supplementary Figs.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">17<\/a>, <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">18<\/a>). In addition, PolaTex exhibits excellent moisture and thermal stability, maintaining stable environmental EM energy recovering performance under conditions of sweating (Supplementary Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">19<\/a>), high temperatures (Supplementary Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">20a\u2013c<\/a>) and high humidity (Supplementary Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">20d, e<\/a>).<\/p>\n<p><b id=\"Fig3\" class=\"c-article-section__figure-caption\" data-test=\"figure-caption-text\">Fig. 3: Mechanical and electrical performance of body dielectric polarization-enabled textile.<\/b><a class=\"c-article-section__figure-link\" data-test=\"img-link\" data-track=\"click\" data-track-label=\"image\" data-track-action=\"view figure\" href=\"https:\/\/www.nature.com\/articles\/s41467-025-64053-2\/figures\/3\" rel=\"nofollow noopener\" target=\"_blank\"><img decoding=\"async\" aria-describedby=\"Fig3\" src=\"https:\/\/www.europesays.com\/ie\/wp-content\/uploads\/2025\/10\/41467_2025_64053_Fig3_HTML.png\" alt=\"figure 3\" loading=\"lazy\" width=\"685\" height=\"729\"\/><\/a><\/p>\n<p><b>a<\/b> Schematic diagram of PolaTex on the skin. <b>b<\/b> Microscopic images of the cotton electrode before and after hydrogel treatment, scale bar represents 0.5\u2009mm. The images provided here are representative of micrographs obtained from three samples. <b>c<\/b> Comparison of air permeability between hydrogel-treated and untreated textiles. <b>d<\/b> Stress-strain curves obtained by sequential multistep stretching and relaxing of hydrogel-modified electronic textiles. The stretching was performed at a fast rate of 5\u2009mm\/s and zero downtime between cycles, showing the mechanical properties of the elastic textile. <b>e<\/b> Electrical output performance of EM recovery under different load resistances. Power density was tested at 50\u2009cm from the laptop. <b>f<\/b> Comparison of recovered EM energy at different distances. <b>g<\/b> Digital photo of PolaTex testing the electrical signal for recovering EM energy. <b>h<\/b> Digital photos of different areas of PolaTex (0.2\u2009cm2, 3\u2009cm2, 25\u2009cm2, 100\u2009cm2) placed on the skin surface. <b>i<\/b> The voltage of EM energy recovered by PolaTex of different areas under the same conditions. Similar results were obtained for PolaTex samples in three independent tests. <b>j<\/b> Schematic diagram of EM energy recovery at different node positions on the human body. <b>k<\/b> Comparison of EM energy recovery at different nodes among different participants. The signal was measured during daily office typing while touching the laptop. <b>l<\/b> Schematic diagram of EM energy recovery with different numbers of nodes on the human body. <b>m<\/b> Comparison of recovered EM energy at different node numbers on the human body of different participants, segments of the columns represent the output of each individual node.<\/p>\n<p>Power density is a key metric for EM energy harvesting devices. As shown in Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#Fig3\" rel=\"nofollow noopener\" target=\"_blank\">3e<\/a>, an output power of 11.02 \u03bcW\/person was achieved under a load resistance of approximately 1\u2009M\u03a9. The power density test process is as follows: a person wearing the PolaTex, sitting at 50\u2009cm from the laptop, and then the voltage signal is measured from the fabric electrodes by an oscilloscope under different external loads (See \u201cMethods\u201d). When we directly touched the laptop for daily typing, the power density obtained is as shown in Supplementary Figs.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">21<\/a>, reaching up to 6.05\u2009mW\/person (Calculated based on U2\/R, where U is voltage, R is load resistance). The recovered energy gradually decreased as the distance from the electrical device increases (Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#Fig3\" rel=\"nofollow noopener\" target=\"_blank\">3f, g<\/a> and Supplementary Figs.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">22<\/a>, <a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">23<\/a>). Increasing the size of PolaTex has no obvious effect on the recovered voltage (Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#Fig3\" rel=\"nofollow noopener\" target=\"_blank\">3h, i<\/a>), while the exposed area of the recycled object has a significant effect on the voltage (Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#Fig2\" rel=\"nofollow noopener\" target=\"_blank\">2h<\/a>). Due to individual physiological differences, the amount of EM energy recovered varied from person to person, even under identical environmental and positional conditions (Supplementary Figs.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">24<\/a>). However, for a particular individual, the recovered energy remained relatively consistent, regardless of the electrode placement, with only minor variations. The testing locations included the wrist, leg, and abdomen (Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#Fig3\" rel=\"nofollow noopener\" target=\"_blank\">3j<\/a> and Supplementary Figs.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">25<\/a>), which suggested that wearable electronic devices placed on the wrist or abdomen can efficiently utilize the recovered energy (Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#Fig3\" rel=\"nofollow noopener\" target=\"_blank\">3k<\/a> and Supplementary Figs.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">25<\/a>). Moreover, when multiple nodes operated simultaneously (Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#Fig3\" rel=\"nofollow noopener\" target=\"_blank\">3l<\/a>), the energy recovered at each node remains comparable to that of an independently operating single node (Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#Fig3\" rel=\"nofollow noopener\" target=\"_blank\">3m<\/a>). This enabled simultaneous energy harvesting across multiple nodes without mutual dependence, ensuring that the energy distribution among different nodes does not compromise overall device performance. We discussed the biological safety of PolaTex under 50\u2009Hz EM field. Both the potential Joule heating effects and electromagnetic radiation exposure were assessed, and no significant hazards were observed under current experimental conditions (Supplementary Tab.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">2<\/a> and Supplementary Note\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">3<\/a>).<\/p>\n<p>Application of body dielectric polarization-enabled textiles in body area networks<\/p>\n<p>Current energy supply solutions typically deliver external energy to energy-consuming terminals through physical energy conversion units, such as coils and power generation devices. However, BAN has many nodes requiring many energy supply entities at each node, which inevitably brings the challenge for seamless integration of distributed energy. The technology proposed in this work tackles this challenge by allowing energy recovery and distribution via the BAN-carrying object (human body) itself.<\/p>\n<p>The energy flow of our body dielectric polarization-enabled technology can be summarized as follows: (1) ambient EM energy is recovered by the human body; (2) the body itself is utilized as a pathway for energy transmission; (3) energy obtained via the PolaTex is then delivered to the corresponding energy consumption position of the BAN, e.g., a wearable device. (Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#Fig4\" rel=\"nofollow noopener\" target=\"_blank\">4a, b<\/a>). Since the placement of energy-consuming devices is inherently determined by the human body, this method of harnessing energy from the body eliminates location constraints and effectively addresses the distributed energy challenge in body area networks (Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#Fig4\" rel=\"nofollow noopener\" target=\"_blank\">4c<\/a>).<\/p>\n<p><b id=\"Fig4\" class=\"c-article-section__figure-caption\" data-test=\"figure-caption-text\">Fig. 4: Application of body dielectric polarization-enabled textiles in body area networks.<\/b><a class=\"c-article-section__figure-link\" data-test=\"img-link\" data-track=\"click\" data-track-label=\"image\" data-track-action=\"view figure\" href=\"https:\/\/www.nature.com\/articles\/s41467-025-64053-2\/figures\/4\" rel=\"nofollow noopener\" target=\"_blank\"><img decoding=\"async\" aria-describedby=\"Fig4\" src=\"https:\/\/www.europesays.com\/ie\/wp-content\/uploads\/2025\/10\/41467_2025_64053_Fig4_HTML.png\" alt=\"figure 4\" loading=\"lazy\" width=\"685\" height=\"717\"\/><\/a><\/p>\n<p><b>a<\/b> Schematic diagram of the EM energy recovery application scenarios. <b>b<\/b> Schematic diagram of a multi-node system based on the EM energy recovery principles. <b>c<\/b> Energy flow pathways in the process of EM energy recovery: from the ambient energy to powering personal electronics. <b>d<\/b> Application of PolaTex for a wireless heart rate monitoring device. <b>e<\/b> PolaTex recovered EM energy at some important anatomical sites. <b>f<\/b> Digital photo of the heart rate band powered by the PolaTex. <b>g<\/b> Data of the heart rate and respiratory rate acquired from a participant during long-term monitoring using an HR belt powered entirely by the developed textile. <b>h<\/b> Schematic diagram of the body dielectric polarization-enabled wristband. <b>i<\/b> Digital photo of the body dielectric polarization-enabled wristband. <b>j<\/b> Photograph of the flexible energy management circuit. <b>k<\/b> Equivalent circuit diagram of the energy management circuit for PolaTex. UVLC: Undervoltage Lockout Circuit, making sure not to start before the voltage is sufficient. <b>l, m<\/b> Application of PolaTex in powering light-emitting fibers. <b>n<\/b> Voltage-time curves of the PolaTex when powering the electronic device, recorded while worn by different human participants, and while not worn (recovery in air).<\/p>\n<p>In practical applications, we demonstrate the PolaTex for powering the heart rate monitoring (HRM) device (Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#Fig4\" rel=\"nofollow noopener\" target=\"_blank\">4d<\/a> and Supplementary Movie\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM6\" rel=\"nofollow noopener\" target=\"_blank\">3<\/a>). By using PolaTex, the ambient EM energy was recovered and rectified into direct current (DC) by an energy management module, which then charged a 10-mF capacitor. This capacitor can power the HRM when its voltage reaches 3\u2009V. The HRM monitors the electrocardiographic (ECG) signals to calculate the heart rate (HR) and transmits the data via Bluetooth to a smartwatch for real-time monitoring (Supplementary Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">26<\/a>). The HRM device, as shown in Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#Fig4\" rel=\"nofollow noopener\" target=\"_blank\">4f<\/a>, did not contain an external power supply in its circuit and relied solely on body dielectric polarization-enabled EM energy recovery as its power source. Using this approach, we have monitored HR and respiratory rate data overnight (Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#Fig4\" rel=\"nofollow noopener\" target=\"_blank\">4g<\/a>), where a significant increase in heart rate was observed after waking up. Moreover, the body dielectric polarization-enabled EM energy recovery technology can be applied in a multi-node configuration at different body locations if needed (Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#Fig4\" rel=\"nofollow noopener\" target=\"_blank\">4e<\/a>). It can be integrated into PolaTex at various positions, such as foot, knee, and wrist nodes as socks, knee-sleeves, and wristbands, respectively.<\/p>\n<p>In addition, we also developed a flexible energy management circuit to stabilize the output voltage at 3.3\u2009V to match the rated voltage of some commercial electronic equipment (Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#Fig4\" rel=\"nofollow noopener\" target=\"_blank\">4g\u2013j<\/a> and Supplementary Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">27<\/a>). The equivalent circuit of energy management is shown in Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#Fig4\" rel=\"nofollow noopener\" target=\"_blank\">4k<\/a>. Its main functions are rectification, load protection, energy storage and voltage regulation output. We also compared the effect of diodes with different reverse leakage currents on the final recovered EM energy (Supplementary Fig.<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">28<\/a> and Supplementary Tab.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">3<\/a>), which is then rectified to charge a 47 \u03bcF capacitor. By connecting the wristband to a light-emitting fiber device (Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#Fig4\" rel=\"nofollow noopener\" target=\"_blank\">4l, m<\/a> and Supplementary Movie\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM7\" rel=\"nofollow noopener\" target=\"_blank\">4<\/a>), it can continuously power the light-emitting fibers during use, enabling operation without an external power source. Furthermore, the wristband-based power supply device can be used to charge an electronic watch (Supplementary Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM1\" rel=\"nofollow noopener\" target=\"_blank\">29<\/a> and Supplementary Movie\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#MOESM8\" rel=\"nofollow noopener\" target=\"_blank\">5<\/a>). We used an oscilloscope to record the voltage-time curve of the complete process of recovering electromagnetic energy and driving electronic devices (Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-64053-2#Fig4\" rel=\"nofollow noopener\" target=\"_blank\">4n<\/a>). When powering different electronic devices, the final output voltage varies depending on the power consumption of each device. In a control experiment where the same device was not in contact with the human body, the energy recovered approaches zero, making it essentially incapable of powering electronic devices, and thus emphasizing the crucial role of human body dielectric polarization effect.<\/p>\n","protected":false},"excerpt":{"rendered":"Concept of body dielectric polarization-enabled body area networks Textile-based body area networks (BAN) require multiple sensors and wireless&hellip;\n","protected":false},"author":2,"featured_media":115298,"comment_status":"","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[271],"tags":[71023,18,9593,1099,19,17,1100,452,7177,133],"class_list":{"0":"post-115297","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-physics","8":"tag-devices-for-energy-harvesting","9":"tag-eire","10":"tag-electrical-and-electronic-engineering","11":"tag-humanities-and-social-sciences","12":"tag-ie","13":"tag-ireland","14":"tag-multidisciplinary","15":"tag-physics","16":"tag-polymers","17":"tag-science"},"share_on_mastodon":{"url":"","error":""},"_links":{"self":[{"href":"https:\/\/www.europesays.com\/ie\/wp-json\/wp\/v2\/posts\/115297","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.europesays.com\/ie\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.europesays.com\/ie\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.europesays.com\/ie\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.europesays.com\/ie\/wp-json\/wp\/v2\/comments?post=115297"}],"version-history":[{"count":0,"href":"https:\/\/www.europesays.com\/ie\/wp-json\/wp\/v2\/posts\/115297\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.europesays.com\/ie\/wp-json\/wp\/v2\/media\/115298"}],"wp:attachment":[{"href":"https:\/\/www.europesays.com\/ie\/wp-json\/wp\/v2\/media?parent=115297"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.europesays.com\/ie\/wp-json\/wp\/v2\/categories?post=115297"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.europesays.com\/ie\/wp-json\/wp\/v2\/tags?post=115297"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}