Baker, in a phone interview Friday, highlighted from the CSB’s update a graphic from a contractor’s July 2025 inspection that illustrated severe deterioration inside the tank.
Based on ultrasonic thickness testing conducted for Nippon Dynawave by contractor Applied Technical Services, the steel tank holding caustic and nearly boiling hot white liquor had deteriorated beyond unsafe levels in some of its lower ringlike sections.
In some of the sections, known as “courses,” the graphic shows that the steel tank had deteriorated to nearly two-thirds of its original design.
Applied Technical Services urged that inspections and repairs be prioritized for three of the five sections of the tank in July of last year, according to the report. Further, the contractor told Nippon that the tank was “not fit for continued service,” and if left unrepaired, there was a “high likelihood / consequence of failure.”
This graph from July 2025 shows that part of the tank shell that failed on May 26 at Nippon was thinner than industry standards.
U.S. Chemical Safety Board, Contributed
Applied Technical Services has locations in Seattle and Portland, but it is unclear why the contractor was performing inspections for Nippon.
Nippon never removed the tank from operation or lessened it to a reduced service level, but they brought in Applied Technical Services for two other inspections the following October and in February of this year.
The report shows that less than an hour before the failure of the tank — which could hold 1.2 million gallons — it was more than 90% full.
Baker said she found it curious that the company would keep it online yet bring in the same inspector two more times.
Baker also pointed out that the CSB is still investigating numerous lingering questions about the tank, such as how it was maintained and how the company determined it was fit for continued service.