Flash flooding that affected parts of Birmingham on 27 August has reignited debate over how urban drainage should be managed as extreme weather becomes more frequent. The event, heavy, short-duration rainfall falling on parched, impermeable surfaces, exposed the limitations of a sewer network designed for a very different climate and urban fabric.

ACO, a supplier of drainage products and systems, has urged local authorities and developers to prioritise surface-level rainfall interception and storage rather than relying on upsized sewers. The company argues that measures such as rain gardens, permeable surfacing and small-scale attenuation installed across streets, car parks and other paved areas can reduce runoff peaks and the likelihood of combined sewer overflows, without the disruption and capital cost of extensive pipework replacement.

Why surface-first measures matter

The argument rests on two interacting trends:

  • Longer dry spells and heatwaves harden soils and reduce infiltration. When intense rain follows, water runs off quickly rather than soaking away.
  • Continued urbanisation, more paving, driveways and vehicle-dominated streets, increases the area of impermeable surface, accelerating runoff.

Together, these trends can deliver large volumes of water to combined sewer systems within minutes, overwhelming capacity and discharging untreated flows into properties, roads and watercourses.

Upsizing sewers is one technical response, but it can be relatively expensive, disruptive and does nothing to reduce the upstream pulse of water. By contrast, a distributed SuDS (sustainable drainage systems) approach seeks to intercept, store and attenuate runoff close to source. Retrofitting dozens of modest interventions across a catchment can compound benefits at system scale with less disruption to communities and infrastructure.

Policy and practice remain uneven

Industry representatives point out that adoption of SuDS in England remains inconsistent in part because Schedule 3 of the Flood and Water Management Act, which would have placed sustainable drainage on a statutory footing, was never enacted. As a result, delivery remains largely policy-driven and is interpreted differently by local authorities and developers, complicating uptake and standardisation.

ACO Water Management head of speficication and design Sam Hawkins, says traditional pipe-upsizing isn’t the answer. “We keep trying to solve the urban flooding issue by upsizing pipes, but that is the most expensive and least effective solution” Instead, he suggests that “the real answer revolves around using a range of hard and soft sustainable drainage systems such as rain gardens and attenuation systems, to reduce the volume of water that makes it to the sewer system. The challenge here is that SuDS uptake remains inconsistent.”

Hawkins also argues that SuDS offer co-benefits: recharging groundwater during droughts and providing amenity and ecological value in urban areas. The dual need to manage both intense rainfall and prolonged dry periods makes such multifunctional design increasingly important, he added.

Technical and delivery considerations for engineers

For practising engineers and infrastructure planners, the discussion prompts several practical considerations:

  • Whole-catchment thinking: Small, distributed measures are only effective if planned and coordinated across catchments to avoid simply moving problems downstream.
  • Retrofit opportunities: Car parks, highway verges, public realm improvements and redevelopment sites offer the most accessible locations for retrofitted SuDS in built-up areas.
  • Maintenance and adoption: Local authority willingness to adopt, inspect and maintain SuDS features affects their long-term performance; unclear ownership risks degradation.
  • Standards and modelling: Design rainfall intensities, runoff coefficients for sealed and unsealed surfaces, and modelling of combined systems must reflect changing climate loading and urban land-use patterns.
  • Funding and disruption: While less disruptive than deep excavation to upsize sewers, SuDS retrofits still require capital and early integration with highways, utilities and planning processes.

The flash floods in the midlands have led to disrupted rail surfaces, traffic congestion to roads, businesses having to close and homes being damaged. While there may be debate about the specific solutions needed, the cost of inaction of such impacts is significant.

Recent UK flash flooding incidents

The UK experienced a series of intense rainfall events that led to widespread surface water and river flooding, damaging property and infrastructure and resulting in several deaths:

  • Northwest England (January 2025): Historic downpours saw 90mm of rain over the New Year period. This led to a major breach of the Bridgewater Canal on January 1, 2025, when an aqueduct over the River Bollin collapsed, flooding the Dunham Treatment Works.
  • Greater Manchester (January 2025): The town of Timperley was completely overcome by rainwater, leading to local outcry after previously planned flood defences had been shelved.
  • Storm Bert (November 2024): As the second named storm of the 2024/25 season, Bert brought 100mm to 150mm of rain to high ground in South Wales, resulting in several deaths.
  • Storm Ashley (October 2024): This storm triggered over 200 flood warnings and alerts across Scotland, Northern Ireland and England, causing a portion of the Thames Path embankment to collapse near Kew Gardens.
  • Central England (September 2024): Three successive low-pressure systems caused the Oxford Radcliffe Observatory to record its wettest calendar month since 1774, flooding several hundred properties.

Like what you’ve read? To receive New Civil Engineer’s daily and weekly newsletters click here.