{"id":93919,"date":"2025-07-26T11:07:17","date_gmt":"2025-07-26T11:07:17","guid":{"rendered":"https:\/\/www.europesays.com\/us\/93919\/"},"modified":"2025-07-26T11:07:17","modified_gmt":"2025-07-26T11:07:17","slug":"nanometric-dual-comb-ranging-using-photon-level-microcavity-solitons","status":"publish","type":"post","link":"https:\/\/www.europesays.com\/us\/93919\/","title":{"rendered":"Nanometric dual-comb ranging using photon-level microcavity solitons"},"content":{"rendered":"<p>Mutually coherent DCR with 1-nm-precision<\/p>\n<p>The interferometric DCR principle is rooted in the Fourier transform relationship, that a temporal shift \u03c4d corresponds to a linear phase of \u03c9\u03c4d in the frequency domain (\u03c9\u2009=\u2009m\u03c9r, where m is the comb line number with respect to the pump and \u03c9r is the angular repetition rate). By measuring the multi-heterodyne phases for the signal and reference arms, denoted as \u03d5sig(\u03c9) and \u03d5ref(\u03c9) in Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig1\" target=\"_blank\" rel=\"noopener\">1<\/a>a, we can derive \u03c4d and distance L as,<\/p>\n<p>$$L=c{\\tau }_{d}\/2=c\\Delta ({\\phi }_{{{{{\\rm{sig}}}}}}(\\omega )-{\\phi }_{{{{{\\rm{ref}}}}}}(\\omega ))\/2\\Delta \\omega .$$<\/p>\n<p>\n                    (1)\n                <\/p>\n<p>The time-of-flight \u03c4d can be determined by linearly fitting \u03d5sig(\u03c9)\u2009\u2212\u2009\u03d5ref(\u03c9) in the frequency domain. Conversely, ref. <a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 10\" title=\"Suh, M.-G. &amp; Vahala, K. J. Soliton microcomb range measurement. Science 359, 884&#x2013;887 (2018).\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#ref-CR10\" id=\"ref-link-section-d116275482e859\" target=\"_blank\" rel=\"noopener\">10<\/a> derived the time-of-flight by locating the RF pulse peaks in the time domain. Here, we refer to these two approaches as fToF and tToF, respectively. For fToF, high mutual coherence and stable \u03d5sig,\u00a0\u03d5ref are the keys for precise DCR. Note that we omit the influence of the air group index and treat the pulse group velocity as the vacuum light velocity c. This group index impact can be included by using two-color measurements<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 33\" title=\"Minoshima, K. &amp; Matsumoto, H. High-accuracy measurement of 240-m distance in an optical tunnel by use of a compact femtosecond laser. Appl. Opt. 39, 5512&#x2013;5517 (2000).\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#ref-CR33\" id=\"ref-link-section-d116275482e875\" target=\"_blank\" rel=\"noopener\">33<\/a>.<\/p>\n<p><b id=\"Fig1\" class=\"c-article-section__figure-caption\" data-test=\"figure-caption-text\">Fig. 1: Coherent dual-comb ranging (DCR) using counter-propagating (CP) solitons.<\/b><a class=\"c-article-section__figure-link\" data-test=\"img-link\" data-track=\"click\" data-track-label=\"image\" data-track-action=\"view figure\" href=\"https:\/\/www.nature.com\/articles\/s41467-025-62022-3\/figures\/1\" rel=\"nofollow noopener\" target=\"_blank\"><img decoding=\"async\" aria-describedby=\"Fig1\" src=\"https:\/\/www.europesays.com\/us\/wp-content\/uploads\/2025\/07\/41467_2025_62022_Fig1_HTML.png\" alt=\"figure 1\" loading=\"lazy\" width=\"685\" height=\"487\"\/><\/a><\/p>\n<p><b>a<\/b> Experimental setup for the CP solitons generation and DCR. ECDL external cavity diode laser, SSBM single-sideband modulator, AOM acoustooptical modulator, FBG fiber Bragg grating, EDFA erbium-doped fiber amplifier, PC polarization controller, Col collimator, BPD balanced photodetector, IM intensity modulator, PM phase modulator, VOA variable optical attenuator. <b>b<\/b> Optical spectra of the CP solitons. The inset shows the nanophotonic chip. <b>c<\/b> Dual-comb inteferogram in the signal and reference arms. <b>d<\/b> Power spectrum of the signal arm and the corresponding phase spectrum. <b>e<\/b> Allan deviation of phase different between the 4th and the 9th lines. <b>f<\/b> Phase difference between the signal and the reference arms measured in 50\u2009\u03bcs. <b>g<\/b> Fitting the phase difference in panel (<b>f<\/b>) yields the distance over 104 time slots. <b>h<\/b> DCR Allan deviation when selecting different number of comb lines for fitting, all showing t\u22121\/2 scaling. The inset shows all the selections yield the same distance, but with different standard deviation (see error bars).<\/p>\n<p>Our setup to generate CP solitons with VFL is shown in Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig1\" target=\"_blank\" rel=\"noopener\">1<\/a>a, see Methods. Optical spectra of the CP soliton microcombs are plotted in Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig1\" target=\"_blank\" rel=\"noopener\">1<\/a>b. One of the microcombs was sent to and reflected from a cooperative target (a mirror) to heterodyne beat with the other microcomb to generate the DCR signals. The dual-comb inteferogram was registered by balanced photodetectors (BPDs) and digitized by an oscilloscope (see \u201cMethods\u201d for details). An example of the interferogram with \u03b4fr\u2009=\u20091.62\u2009MHz is shown in Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig1\" target=\"_blank\" rel=\"noopener\">1<\/a>c. We then Fourier transform the RF pulses to have the power spectrum and \u03d5sig(\u03c9) shown in Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig1\" target=\"_blank\" rel=\"noopener\">1<\/a>d. Mutual coherence enables direct transform without any digital correction as needed in many cases<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 3\" title=\"Zhu, Z. &amp; Wu, G. Dual-comb ranging. Engineering 4, 772&#x2013;778 (2018).\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#ref-CR3\" id=\"ref-link-section-d116275482e967\" target=\"_blank\" rel=\"noopener\">3<\/a>, which can greatly relax computation burden in future PIC-based DCR systems. A power rSNR (signal over average noise floor) exceeding 80\u2009dB can be obtained within a measurement time t\u2009=\u20090.5\u2009s. To show the phase stability between the CP solitons, we plot the Allan deviation of \u03d5sig(9\u03c9r)\u2009\u2212\u2009\u03d5sig(4\u03c9r) in Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig1\" target=\"_blank\" rel=\"noopener\">1<\/a>e, which scales as t\u22121\/2 and reaches 0.5\u2009mrad at 0.1\u2009s. The relative timing stability between CP solitons can be estimated as (\u03d5sig(9\u03c9r)\u2009\u2212\u2009\u03d5sig(4\u03c9r))\/5\u03c9r, reaching 0.1\u2009fs at 0.1\u2009s.<\/p>\n<p>Then, we analyze \u03d5sig\u2009\u2212\u2009\u03d5ref using RF pulses measured within 50\u2009\u03bcs and observe an excellent linearity for the used N\u2009=\u200930 lines (excluding the pump, see Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig1\" target=\"_blank\" rel=\"noopener\">1<\/a>f). Fitting the relative phase yields the distance in multiple 50\u2009\u03bcs slots (Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig1\" target=\"_blank\" rel=\"noopener\">1<\/a>g). The DCR precision is evaluated by Allan deviation and shows a t\u22121\/2 scaling with a normalized precision of 0.6\u2009nm\\(\\cdot \\sqrt{{{{{\\rm{s}}}}}}\\) (Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig1\" target=\"_blank\" rel=\"noopener\">1<\/a>h). The normalization does not include the information of absolute distance. The distance from the collimator to the target is about 13\u2009cm (fiber length from the collimator to the signal BPD is about 3\u2009m), when evaluating this precision. We further changed the used comb line number from N\u2009=\u200930 to other numbers to evaluate the precision. Normalized precision as high as 0.5\u2009nm\\(\\cdot \\sqrt{{{{{\\rm{s}}}}}}\\) (reaching 1.1-nm-precision at 0.2\u2009s) is possible for our system. The precision is reached by pure fTOF without using interferometric phase of a carrier frequency<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 2\" title=\"Coddington, I., Swann, W. C., Nenadovic, L. &amp; Newbury, N. R. Rapid and precise absolute distance measurements at long range. Nat. Photonics 3, 351&#x2013;356 (2009).\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#ref-CR2\" id=\"ref-link-section-d116275482e1116\" target=\"_blank\" rel=\"noopener\">2<\/a>. The inset of Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig1\" target=\"_blank\" rel=\"noopener\">1<\/a>h confirms that our measurement always yields the same distance when using different comb line number N.<\/p>\n<p>Precision of DCR<\/p>\n<p>Theoretically, the DCR precision is derived as (see \u201cMethods\u201d),<\/p>\n<p>$$\\sigma=\\frac{\\sqrt{3}\\sqrt{1+\\alpha }c}{N{\\omega }_{r}\\sqrt{N}\\sqrt{{{{{{\\rm{rSNR}}}}}}_{{{{{\\rm{eff}}}}}}}}=\\frac{\\sqrt{3}\\sqrt{1+\\alpha }c}{2\\pi B\\sqrt{N}\\sqrt{{{{{{\\rm{rSNR}}}}}}_{{{{{\\rm{eff}}}}}}}},$$<\/p>\n<p>\n                    (2)\n                <\/p>\n<p>where rSNReff is the effective rSNR for the signal arm, B\u2009=\u2009Nfr is the used comb bandwidth, and \u03b1 is the ratio between the rSNReff in the reference and the signal arms. rSNR(m) is defined as the RF power ratio between the mth line and the average noise floor (see Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig1\" target=\"_blank\" rel=\"noopener\">1<\/a>d for illustration). Note that rSNR is defined in the frequency domain and differs from the ranging signal-to-noise ratio used in ref. <a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 4\" title=\"Caldwell, E. D., Sinclair, L. C., Newbury, N. R. &amp; Deschenes, J.-D. The time-programmable frequency comb and its use in quantum-limited ranging. Nature 610, 667&#x2013;673 (2022).\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#ref-CR4\" id=\"ref-link-section-d116275482e1332\" target=\"_blank\" rel=\"noopener\">4<\/a>. The relationship between rSNReff and rSNR(m) is discussed in Methods and Supplementary Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#MOESM1\" target=\"_blank\" rel=\"noopener\">1<\/a>. The phase of a measured RF tone has contribution from both the signal and noise (inset of Fig.\u00a0<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig2\" target=\"_blank\" rel=\"noopener\">2<\/a>a). Thus, the phase deviation of a measured RF line (\u03c3\u03d5) is determined by the rSNR determines as,<\/p>\n<p>$${\\sigma }_{\\phi }(m,t)=\\frac{1}{\\sqrt{{{{{\\rm{rSNR}}}}}(m,t)}}.$$<\/p>\n<p>\n                    (3)\n                <\/p>\n<p>\u03c3\u03d5(4,\u00a0t) plotted in Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig2\" target=\"_blank\" rel=\"noopener\">2<\/a>a confirms this relationship. \u03c3\u03d5(m,\u00a0t) for other comb lines also support Eq. (<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"equation anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Equ3\" target=\"_blank\" rel=\"noopener\">3<\/a>) (Supplementary Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#MOESM1\" target=\"_blank\" rel=\"noopener\">3<\/a>). \u03c3\u03d5 divided by 2\u03c0B yields the timing (thus, distance) deviation. The \\(1\/\\sqrt{N}\\) term is added as fitting multiple points leads to higher stability<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 34\" title=\"Montgomery, D. C., Peck, E. A. &amp; Vining, G. G. Introduction to Linear Regression Analysis (John Wiley &amp; Sons, 2021).\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#ref-CR34\" id=\"ref-link-section-d116275482e1514\" target=\"_blank\" rel=\"noopener\">34<\/a> (Supplementary Note\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#MOESM1\" target=\"_blank\" rel=\"noopener\">1<\/a>). To verify it, we analyzed the DCR precision for a fixed B\u2009=\u20093.2 THz but selecting lines with different spacings (thus, different N). A \\(1\/\\sqrt{N}\\) scaling is observed for the normalized precision (Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig2\" target=\"_blank\" rel=\"noopener\">2<\/a>b). Finally, \u03b1 is included as the DCR signal is derived from the phase difference between the signal and reference arms (Eq. (<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"equation anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Equ1\" target=\"_blank\" rel=\"noopener\">1<\/a>)).<\/p>\n<p><b id=\"Fig2\" class=\"c-article-section__figure-caption\" data-test=\"figure-caption-text\">Fig. 2: Measurement precision of DCR.<\/b><a class=\"c-article-section__figure-link\" data-test=\"img-link\" data-track=\"click\" data-track-label=\"image\" data-track-action=\"view figure\" href=\"https:\/\/www.nature.com\/articles\/s41467-025-62022-3\/figures\/2\" rel=\"nofollow noopener\" target=\"_blank\"><img decoding=\"async\" aria-describedby=\"Fig2\" src=\"https:\/\/www.europesays.com\/us\/wp-content\/uploads\/2025\/07\/41467_2025_62022_Fig2_HTML.png\" alt=\"figure 2\" loading=\"lazy\" width=\"685\" height=\"217\"\/><\/a><\/p>\n<p><b>a<\/b> Allan deviation of the phase of the 4th comb line, which equals 1\/\\(\\sqrt{{{{{\\rm{rSNR}}}}}}\\). The inset shows an illustration of the relationship between rSNR and phase deviation. <b>b<\/b> DCR precision for a fixed comb bandwidth B = 3.2 THz, but selecting comb lines with different spacing (thus, different used comb line number N). The inset shows the normalized precision improves as N\u22121\/2. <b>c<\/b> Measured DCR precision agrees with the theoretical precision determined by Eq. (<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"equation anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Equ2\" target=\"_blank\" rel=\"noopener\">2<\/a>). The inset confirms the N\u22123\/2 trend in our theory.<\/p>\n<p>Our measured DCR precision is in excellent agreement with the theory (Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig2\" target=\"_blank\" rel=\"noopener\">2<\/a>c). The precision no longer improves evidently for N\u2009&gt;\u200940. This is because rSNR(m) decreases for large \u2223m\u2223, resulting in a reduced rSNReff. We numerically calculated rSNReff based on rSNR(m) of the used microcomb lines (see \u201cMethods\u201d and Supplementary Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#MOESM1\" target=\"_blank\" rel=\"noopener\">1<\/a> for details). After taking the decrease of rSNReff into account, a scaling of N\u22123\/2 is observed (see Eq. (<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"equation anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Equ2\" target=\"_blank\" rel=\"noopener\">2<\/a>) and inset of Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig2\" target=\"_blank\" rel=\"noopener\">2<\/a>b).<\/p>\n<p>Therefore, the high DCR precision in our system can be attributed to the high rSNR and broad usable bandwidth. rSNReff can be further written as,<\/p>\n<p>$${{{{{\\rm{rSNR}}}}}}_{{{{{\\rm{eff}}}}}}=\\frac{K(B)}{{N}^{2}}\\frac{{P}_{{{{{\\rm{LO}}}}}}{P}_{{{{{\\rm{sig}}}}}}}{{S}_{{{{{\\rm{n}}}\\,}}}{f}_{{{{{\\rm{BW}}}}}}}=\\frac{K(B)}{{N}^{2}}\\frac{{f}_{r}^{2}{E}_{{{{{\\rm{LO}}}}}}{E}_{{{{{\\rm{sig}}}}}}t}{{S}_{{{{{\\rm{n}}}}}}},$$<\/p>\n<p>\n                    (4)\n                <\/p>\n<p>where Sn is the spectral power density of the RF noise floor, and fBW\u2009=\u20091\/t is the resolution bandwidth; Psig(LO) and Esig(LO) are the received signal (local) optical comb power and energy, respectively; K(B) is a conversion coefficient that includes response from the BPD and variation of rSNR(m) within the used bandwidth. By combining Eq. (<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"equation anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Equ2\" target=\"_blank\" rel=\"noopener\">2<\/a>) and Eq. (<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"equation anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Equ4\" target=\"_blank\" rel=\"noopener\">4<\/a>), we have the DCR precision as,<\/p>\n<p>$$\\sigma=\\frac{\\sqrt{3K(B)(1+\\alpha ){S}_{{{{{\\rm{n}}}}}}}\\sqrt{N}c}{2\\pi B\\sqrt{{P}_{{{{{\\rm{LO}}}}}}{P}_{{{{{\\rm{sig}}}}}}t}}=\\frac{\\sqrt{3K(B)(1+\\alpha ){S}_{{{{{\\rm{n}}}}}}}\\sqrt{N}c}{{\\omega }_{r}B\\sqrt{{E}_{{{{{\\rm{LO}}}}}}{E}_{{{{{\\rm{sig}}}}}}t}}.$$<\/p>\n<p>\n                    (5)\n                <\/p>\n<p>It can be seen that \u03c3 is proportional to \\(\\sqrt{N}\\) for a given bandwidth B and comb powers. The comb power is ultimately limited by the saturation of the BPDs. Thus, small comb line numbers for microcombs are beneficial for enhancing DCR precision, but at penalty of a shorter non-ambiguity range due to the large line spacing \u03c9r. The non-ambiguity range can be extended by swapping the signal and local combs for measurements<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 2\" title=\"Coddington, I., Swann, W. C., Nenadovic, L. &amp; Newbury, N. R. Rapid and precise absolute distance measurements at long range. Nat. Photonics 3, 351&#x2013;356 (2009).\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#ref-CR2\" id=\"ref-link-section-d116275482e2266\" target=\"_blank\" rel=\"noopener\">2<\/a>,<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 10\" title=\"Suh, M.-G. &amp; Vahala, K. J. Soliton microcomb range measurement. Science 359, 884&#x2013;887 (2018).\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#ref-CR10\" id=\"ref-link-section-d116275482e2269\" target=\"_blank\" rel=\"noopener\">10<\/a>.<\/p>\n<p>DCR with intensity loss or noise<\/p>\n<p>Due to small N, only low comb power and pulse energy are needed for precise DCR when using microcombs (Eqs. (<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"equation anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Equ2\" target=\"_blank\" rel=\"noopener\">2<\/a>), (<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"equation anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Equ5\" target=\"_blank\" rel=\"noopener\">5<\/a>)). In experiments, we adjusted the loss in the signal arm (Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig1\" target=\"_blank\" rel=\"noopener\">1<\/a>a) to measure DCR precision under different received powers. When reducing the power to 7 pW (attenuated by 67\u2009dB), the dual-comb interferogram is already buried in the noise (Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig3\" target=\"_blank\" rel=\"noopener\">3<\/a>a). However, an RF comb with rSNR over 10\u2009dB can still be obtained after coherently averaging 0.5\u2009s data (Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig3\" target=\"_blank\" rel=\"noopener\">3<\/a>b). Mutual coherence for VFL solitons is the key to coherent averaging and resolving these RF tones. The low power measurement suggests our system can also work for non-cooperative targets.<\/p>\n<p><b id=\"Fig3\" class=\"c-article-section__figure-caption\" data-test=\"figure-caption-text\">Fig. 3: DCR with low received power and strong intensity noise.<\/b><a class=\"c-article-section__figure-link\" data-test=\"img-link\" data-track=\"click\" data-track-label=\"image\" data-track-action=\"view figure\" href=\"https:\/\/www.nature.com\/articles\/s41467-025-62022-3\/figures\/3\" rel=\"nofollow noopener\" target=\"_blank\"><img decoding=\"async\" aria-describedby=\"Fig3\" src=\"https:\/\/www.europesays.com\/us\/wp-content\/uploads\/2025\/07\/41467_2025_62022_Fig3_HTML.png\" alt=\"figure 3\" loading=\"lazy\" width=\"685\" height=\"435\"\/><\/a><\/p>\n<p><b>a<\/b> Dual-comb interferogram signal with a received power of 7\u2009pW. <b>b<\/b> RF spectrum of the signal in panel (<b>a<\/b>) after t\u2009=\u20090.5\u2009s coherent averaging. <b>c<\/b> DCR Allan deviation of a series of received powers, all exhibiting t\u22121\/2 scaling. <b>d<\/b> Normalized DCR precision, showing an inverse square-root relationship with the received power. <b>e<\/b> Measured RF pulses have randomly fluctuating amplitudes when introducing intensity noise on the received microcomb. <b>f<\/b> Measured distance in five 5 ms slots separated by 0.1 s (50 \u03bcs per measurement point) and solid lines are the average distance. <b>g<\/b> DCR Allan deviation under different intensity noise. The inset shows the distribution of the RF pulse amplitude. In the absence of intensity noise, the amplitude has a 2% fluctuation. The added intensity noise can introduce 30% amplitude fluctuation. <b>h<\/b> Deterioration of the rSNR under different intensity noise, which results in the increase of the DCR Allan deviation. The error bars in panel (<b>d,<\/b> <b>h<\/b>) correspond to the standard deviation in multiple measurements.<\/p>\n<p>The DCR Allan deviation still scales as t\u22121\/2, but with a lower normalized precision of 300\u2009nm\\(\\cdot \\sqrt{{{{{\\rm{s}}}}}}\\) (top curve in Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig3\" target=\"_blank\" rel=\"noopener\">3<\/a>c). It means a micron-precision can be obtained in 0.1\u2009s using a microcomb with 5.5\u2009\u00d7\u200910\u22124 photon per pulse. Although a single microcavity soliton has an extremely low photon number, the total photon number used in 0.1\u2009s is 5.5\u2009\u00d7\u2009106 considering its 100\u2009GHz repetition rate. The Allan deviation for a series of received powers is plotted in Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig3\" target=\"_blank\" rel=\"noopener\">3<\/a>c, all exhibiting t\u22121\/2 scaling. The normalized DCR precision decreases with the received power in a square-root trend, consistent with Eqs. (<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"equation anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Equ2\" target=\"_blank\" rel=\"noopener\">2<\/a>), (<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"equation anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Equ5\" target=\"_blank\" rel=\"noopener\">5<\/a>) (Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig3\" target=\"_blank\" rel=\"noopener\">3<\/a>d).<\/p>\n<p>Since the fToF-DCR relies upon optical phase measurements, our system is immune against intensity fluctuations. To showcase this feature, we inserted an intensity modulator (IM) and drove it by a broadband noise in the signal arm (Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig1\" target=\"_blank\" rel=\"noopener\">1<\/a>a). The measured RF pulses have strong fluctuations in the amplitude (Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig3\" target=\"_blank\" rel=\"noopener\">3<\/a>e). Despite these fluctuations, the measured average distance remains the same for five 5\u2009ms slots separated by 0.1\u2009s (t\u2009=\u200950\u2009\u03bcs for a single data point, see Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig3\" target=\"_blank\" rel=\"noopener\">3<\/a>f). The distribution of the normalized RF pulse amplitudes (normalized by the average amplitude) subject to different intensity noise levels is shown in the inset of Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig3\" target=\"_blank\" rel=\"noopener\">3<\/a>g; the blue one is the case without IM noise. We used the standard deviation \u03c3int of this distribution to quantify the noise level. The added intensity noise can cause the RF pulses to have a 30% intensity fluctuation (see the labeled \u03c3int in the inset). DCR Allan deviation retains the t\u22121\/2 scaling in the presence of the intensity noise (Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig3\" target=\"_blank\" rel=\"noopener\">3<\/a>g, average received power is 15\u2009\u03bcW). Nanometer-scale precision is still possible with \u03c3int=30%.<\/p>\n<p>The Allan deviation does increase with \u03c3int, as the intensity noise reduces rSNR. rSNReff for the used 30 lines decreases with a slope of \u22120.26 in a log-log plot versus \u03c3int, while the change of the DCR Allan deviation has a slope of 0.13 (Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig3\" target=\"_blank\" rel=\"noopener\">3<\/a>h). Such a \u00a0\u22120.5 relationship between them further strengthens our theory in Eq. (<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"equation anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Equ2\" target=\"_blank\" rel=\"noopener\">2<\/a>). Note that the rSNR reduction does not impact the DCR measured distance (Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig3\" target=\"_blank\" rel=\"noopener\">3<\/a>f); it only means a longer measurement time is needed to reach a desired precision. The influence of intensity noise on ranging precision has also been evaluated for the dispersive interferometry technique using microcombs (see Supplement in ref. <a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 26\" title=\"Jang, Y.-S. et al. Nanometric precision distance metrology via hybrid spectrally resolved and homodyne interferometry in a single soliton frequency microcomb. Phys. Rev. Lett. 126, 023903 (2021).\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#ref-CR26\" id=\"ref-link-section-d116275482e2484\" target=\"_blank\" rel=\"noopener\">26<\/a>). Measurements and analyses therein exhibit a \u00a0~1 slope for ranging precision versus intensity noise, much larger than the 0.13 slope observed in Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig3\" target=\"_blank\" rel=\"noopener\">3<\/a>h. We also used the RF pulse peak position for ranging (tToF-DCR), and intensity noise was observed to impact ranging precision stronger (see Supplementary Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#MOESM1\" target=\"_blank\" rel=\"noopener\">5<\/a>). Supplementary Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#MOESM1\" target=\"_blank\" rel=\"noopener\">5<\/a> also suggests the decrease of rSNR in Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig3\" target=\"_blank\" rel=\"noopener\">3<\/a>h mainly results from the reduction of the average received power caused by larger noise added to the IM. Although heterodyne detection was used in chaotic ranging in ref. <a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 27\" title=\"Lukashchuk, A., Riemensberger, J., Tusnin, A., Liu, J. &amp; Kippenberg, T. J. Chaotic microcomb-based parallel ranging. Nat. Photonics 17, 814&#x2013;821 (2023).\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#ref-CR27\" id=\"ref-link-section-d116275482e2501\" target=\"_blank\" rel=\"noopener\">27<\/a>, intensity cross-correlation was used for ranging, and intensity noise should also impact the measurement precision. The low intensity noise susceptibility can be useful when the measured target surface has varying reflection coefficients and may be used to distinguish amplitude and phase fluctuations induced by air turbulence<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 35\" title=\"Giorgetta, F. R. et al. Broadband phase spectroscopy over turbulent air paths. Phys. Rev. Lett. 115, 103901 (2015).\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#ref-CR35\" id=\"ref-link-section-d116275482e2505\" target=\"_blank\" rel=\"noopener\">35<\/a>.<\/p>\n<p>Near-Megahertz-DCV measurements<\/p>\n<p>The high rSNR also enables DCR using a single-frame interferogram at a rate of \u03b4fr\u2009=\u20091.83\u2009MHz, i.e., DCV at a rate up to \u03b4fr\/2. Similar single-frame DCR was demonstrated in ref. <a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 9\" title=\"Trocha, P. et al. Ultrafast optical ranging using microresonator soliton frequency combs. Science 359, 887&#x2013;891 (2018).\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#ref-CR9\" id=\"ref-link-section-d116275482e2533\" target=\"_blank\" rel=\"noopener\">9<\/a>, but optical power amplification was used. Here, we implement it without optical amplification. We experimentally inserted a phase-modulator (PM) into the signal arm (Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig1\" target=\"_blank\" rel=\"noopener\">1<\/a>a). By driving the PM with sine-waves, the optical path length for the signal microcomb vibrates periodically. Figure\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig4\" target=\"_blank\" rel=\"noopener\">4<\/a>a shows the DCR-measured optical path length change with a \u00a0~1\u2009\u03bcm amplitude at update rates of 125\u2009kHz and 1.83\u2009MHz, when driving the PM at frequencies of 20 and 900\u2009kHz, respectively. The measured distance changes follow the sine-drive signals (Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig4\" target=\"_blank\" rel=\"noopener\">4a<\/a>). Data points appear sparse for the 900\u2009kHz phase modulation, which was measured at a update rate of 1.83\u2009MHz. However, the measurement still satisfies the Nyquist-Shannon sampling theorem.<\/p>\n<p><b id=\"Fig4\" class=\"c-article-section__figure-caption\" data-test=\"figure-caption-text\">Fig. 4: Near Megahertz dual-comb vibration (DCV) measurements.<\/b><a class=\"c-article-section__figure-link\" data-test=\"img-link\" data-track=\"click\" data-track-label=\"image\" data-track-action=\"view figure\" href=\"https:\/\/www.nature.com\/articles\/s41467-025-62022-3\/figures\/4\" rel=\"nofollow noopener\" target=\"_blank\"><img decoding=\"async\" aria-describedby=\"Fig4\" src=\"https:\/\/www.europesays.com\/us\/wp-content\/uploads\/2025\/07\/41467_2025_62022_Fig4_HTML.png\" alt=\"figure 4\" loading=\"lazy\" width=\"685\" height=\"415\"\/><\/a><\/p>\n<p><b>a<\/b> Measured distance change with drive frequencies of 20 or 900\u2009kHz. The received microcomb power was about 35\u2009\u03bcW. <b>b<\/b> DCV spectra measured at three drive frequencies, all yielding sharp peaks with a high signal-to-noise ratio (SNR). The inset shows the measured vibration amplitude versus the drive power of the phase modulator (PM). <b>c<\/b> The DCV sensitivity (determined by the noise floor in panel (<b>b<\/b>) scales in a square-root way with the received microcomb power. <b>d<\/b> Deduced rSNR for a single-frame inteferogram under different received powers. This rSNR should exceed 3\u2009dB for a reliable DCV measurement. The error bars correspond to the standard deviation in multiple measurements. <b>e<\/b> The highest vibration frequency that can be measured with different received powers. Below 200\u2009nW power, the highest frequency decreases linearly with the power. When the comb line number becomes larger for a fixed total power, DCV at \u03b4fr\/2 will need a higher received power.<\/p>\n<p>Then, we analyzed the DCR-measured distance change in the frequency domain. A Blackman window was included to minimize spectral leakage in fast Fourier transform (FFT) in this analysis. In the frequency domain, the measured distance changes correspond to sharp peaks at 20, 200 and 900\u2009kHz as shown in Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig4\" target=\"_blank\" rel=\"noopener\">4<\/a>b (drive frequency at 200\u2009kHz was also measured). The corresponding peak intensities are the same for all the three drive frequencies and are about 66\u2009dB higher than the average noise floor. When varying the drive power from \u00a0\u221210 to 20\u2009dBm for the PM, we observed the peak amplitude scales in a square-root way with the drive power for all the three drive frequencies (inset of Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig4\" target=\"_blank\" rel=\"noopener\">4<\/a>b). Such a relationship verifies the high accuracy of our DCV measurements.<\/p>\n<p>The noise floor for the power spectral density in Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig4\" target=\"_blank\" rel=\"noopener\">4<\/a>b provides a measure of the DCV sensitivity. We summarize this sensitivity versus received powers in Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig4\" target=\"_blank\" rel=\"noopener\">4<\/a>c. For a nearly white noise floor, its noise spectral amplitude density has a linear relationship with the Allan deviation in DCR<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 36\" title=\"Barnes, J. A. et al. Characterization of frequency stability. IEEE Trans. Instrum. Meas. IM-20, 105&#x2013;120 (1971).\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#ref-CR36\" id=\"ref-link-section-d116275482e2611\" target=\"_blank\" rel=\"noopener\">36<\/a>. Since the DCR precision has an inverse square-root relationship with the received power (Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig3\" target=\"_blank\" rel=\"noopener\">3<\/a>d and Eqs. (<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"equation anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Equ2\" target=\"_blank\" rel=\"noopener\">2<\/a>), (<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"equation anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Equ4\" target=\"_blank\" rel=\"noopener\">4<\/a>)), the measured DCV sensitivity also follows an inverse square-root scaling with the received power, and reaches a sensitivity of 0.4\u2009nm\/\\(\\sqrt{{{{{\\rm{Hz}}}}}}\\) (Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig4\" target=\"_blank\" rel=\"noopener\">4<\/a>c).<\/p>\n<p>To measure vibration at \u03b4fr\/2, the received power should guarantee a sufficient rSNR(m, 1\/\u03b4fr) for single-interferogram DCR. It is technically challenging to quantify rSNR(m, 1\/\u03b4fr) directly, as fBW\u2009=\u2009\u03b4fr for a single-interferogram measurement. In practice, we derive it from rSNR at t\u2009=\u2009100\u2009\u03bcs, using the relationship that rSNR scales linearly with t for VFL solitons<a data-track=\"click\" data-track-action=\"reference anchor\" data-track-label=\"link\" data-test=\"citation-ref\" aria-label=\"Reference 16\" title=\"Wang, Z. et al. Rhythmic soliton interactions for integrated dual-microcomb spectroscopy. Phys. Rev. X 15, 011061 (2025).\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#ref-CR16\" id=\"ref-link-section-d116275482e2705\" target=\"_blank\" rel=\"noopener\">16<\/a>. The minimum rSNR(m, 1\/\u03b4fr) among the used 30 lines under different received powers is plotted in Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig4\" target=\"_blank\" rel=\"noopener\">4<\/a>d. Our data process practice suggests that the minimum rSNR(m, 1\/\u03b4fr) should exceed 3\u2009dB to enable a reliable measurement. The received power needed to reach this threshold is about 100\u2009nW (about 10 photon per pulse). For lower powers, we need to average longer time to reach the required rSNR, and the needed time t increases linearly with decreasing Psig (Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig4\" target=\"_blank\" rel=\"noopener\">4<\/a>e). Therefore, the highest vibration frequency decreases linearly with the received power for Psig\u20094), the highest measurable DCV frequency decreases linearly with N for a given received microcomb power (Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig4\" target=\"_blank\" rel=\"noopener\">4<\/a>e). According to Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"figure anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#Fig4\" target=\"_blank\" rel=\"noopener\">4<\/a>e, the total signal photons needed in a single measurement is about 0.9 million, which is orders of magnitude lower than most DCR reports except for the time-programmable comb (see Supplementary Fig.\u2009<a data-track=\"click\" data-track-label=\"link\" data-track-action=\"supplementary material anchor\" href=\"http:\/\/www.nature.com\/articles\/s41467-025-62022-3#MOESM1\" target=\"_blank\" rel=\"noopener\">6<\/a>).<\/p>\n","protected":false},"excerpt":{"rendered":"Mutually coherent DCR with 1-nm-precision The interferometric DCR principle is rooted in the Fourier transform relationship, that a&hellip;\n","protected":false},"author":3,"featured_media":93920,"comment_status":"","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[25],"tags":[62057,10046,62058,10047,492,159,62059,67,132,68],"class_list":{"0":"post-93919","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-physics","8":"tag-frequency-combs","9":"tag-humanities-and-social-sciences","10":"tag-integrated-optics","11":"tag-multidisciplinary","12":"tag-physics","13":"tag-science","14":"tag-solitons","15":"tag-united-states","16":"tag-unitedstates","17":"tag-us"},"share_on_mastodon":{"url":"https:\/\/pubeurope.com\/@us\/114919220680205852","error":""},"_links":{"self":[{"href":"https:\/\/www.europesays.com\/us\/wp-json\/wp\/v2\/posts\/93919","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.europesays.com\/us\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.europesays.com\/us\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.europesays.com\/us\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.europesays.com\/us\/wp-json\/wp\/v2\/comments?post=93919"}],"version-history":[{"count":0,"href":"https:\/\/www.europesays.com\/us\/wp-json\/wp\/v2\/posts\/93919\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.europesays.com\/us\/wp-json\/wp\/v2\/media\/93920"}],"wp:attachment":[{"href":"https:\/\/www.europesays.com\/us\/wp-json\/wp\/v2\/media?parent=93919"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.europesays.com\/us\/wp-json\/wp\/v2\/categories?post=93919"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.europesays.com\/us\/wp-json\/wp\/v2\/tags?post=93919"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}