The feedstock characteristics reported in Table 1 establish the common physicochemical boundary conditions for interpretation of the following thermal and emission responses. The 25.0 wt% moisture content imposes an appreciable evaporative heat demand before vigorous devolatilization, while the 18.1 wt% ash fraction contributes inert thermal mass and influences heat transfer through the fuel bed. Previous fixed-bed MSW investigations have demonstrated that moisture strongly affects evaporation time, combustion duration, temperature evolution, and devolatilization20, whereas ash content modifies combustion rate, burnout, and residual-carbon conversion5. The controlled 30 mm particle-size class is also important because characteristic MSW size affects bed bulk density, porosity, combustion-front development, temperature distribution, and CO/CO₂ release4. Against this common feedstock background, the 0.2 wt% N and 0.2 wt% S contents provide the parent-element inventories relevant to the nitrogen- and sulfur-containing species discussed below. Consequently, comparisons among the four operating modes are interpreted in terms of changes in the combustion environment rather than intentional differences in feed mass, characteristic particle size, or elemental composition.
Interpretation of the following results distinguishes between quantities directly observed experimentally and mechanisms used to explain those observations. The directly measured evidence consists of the seven transient temperature histories and the time-resolved concentrations of the analyzed gas species under the four operating modes. Consequently, statements such as “lower CO concentration,” “smoother temperature profile,” “reduced CH₄ peak,” or “lower HCN/NO response” refer directly to the experimental data. In contrast, ionic wind, electrohydrodynamic momentum transfer, redistribution of charged species, local electric-field structure, and ion-enhanced microscale mixing were not independently resolved inside the reacting chamber. These phenomena are therefore invoked only as mechanistic interpretations that are physically consistent with established electric-field-assisted combustion studies6,7,8,12,13. In particular, electric-field studies have demonstrated that forces acting on charged flame species can transfer momentum to the surrounding neutral gas and alter flame structure, temperature distribution, and transport12,13. The present results are assessed against this established physical framework without treating the measured thermal or emission response as direct measurement of ionic wind or local charge transport.
The same evidence boundary applies to interpretation of the HHO-assisted cases. HHO was experimentally introduced as an electrolysis-derived H₂/O₂ co-feed, and the direct observations comprise the resulting changes in temperature and gas-species concentrations. H, O, OH, HO₂, and related reactive intermediates were not measured by optical, laser-based, or spectroscopic diagnostics. Consequently, references below to radical-mediated or H₂/O₂ reaction pathways represent chemically plausible mechanisms used to interpret the measured response and should not be understood as direct detection, quantification, or demonstration of the corresponding radical species.
Temperature profile behavior under ion assistance and HHO addition
Figure 3 presents the transient temperature profiles recorded by seven thermocouples under four operating modes: Fig. 3a represents the conventional combustion condition without ion assistance, Fig. 3b shows the effect of activating the ion field, Fig. 3c illustrates the response after adding HHO without ion assistance, and Fig. 3d presents the combined case of ion assistance with HHO addition. These temperature histories provide direct insight into ignition behavior, heat-release intensity, combustion-front propagation, thermal uniformity, and cooling behavior inside the incineration zone.
In Fig. 3a, the Ion OFF case shows the highest and most irregular temperature peaks. Several thermocouples exhibit abrupt increases above the surrounding thermal field, indicating localized hot spots and non-uniform combustion-front movement. Although the high peak temperatures confirm strong heat release, the large fluctuations suggest that combustion is governed by unstable volatile release, uneven oxygen distribution, and localized oxidation zones. This condition can support intense combustion, but it also increases the probability of thermal stress, incomplete oxidation in colder regions, and pollutant formation in poorly mixed zones.
In Fig. 3b, activation of the negative-ion source is associated with a more controlled thermal response than under Ion OFF operation. Peak temperatures decrease, abrupt local excursions become less pronounced, and the thermocouple histories show greater temporal and spatial coherence. The measured response is consistent with modification of the near-inlet combustion environment by charge-assisted transport.
In Fig. 3c, HHO addition under Ion OFF operation produces a distinct measured thermal response. The temperature profiles become broader, and several thermocouples remain elevated for a longer portion of the active combustion period. These observations demonstrate that the H₂/O₂ co-feed modifies heat-release behavior and are consistent with enhanced hydrogen–oxygen oxidation chemistry.
In Fig. 3d, the combined Ion ON with HHO case provides the most balanced temperature behavior. The temperature field remains sufficiently intense for effective combustion, but excessive localized peaks are suppressed. The profiles show improved coordination among thermocouple locations, smoother temperature decay, and more controlled heat release. The measured response indicates that simultaneous HHO enrichment and ion activation modifies the thermal behavior more favorably than either assistance mode alone. H₂/O₂-mediated reaction chemistry and charge-associated transport provide plausible complementary explanations for this response, but neither the radical field nor the local electrohydrodynamic flow field was independently measured. The physical meaning of this result is that the combined mode does not simply increase the temperature; it improves the quality of combustion by converting an unstable, hot-spot-dominated process into a more uniform and controlled oxidation environment.
The superiority of Ion ON with HHO is therefore based on the balance between combustion intensity and thermal stability. A favorable incineration process should not be judged only by the highest peak temperature, because excessive peaks can increase thermal stress and promote unwanted emission pathways. Instead, the desired condition is one that maintains adequate heat release, avoids severe hot spots, promotes stable flame propagation, and supports complete burnout. The Ion ON with HHO case satisfies these requirements most effectively, demonstrating the favorable combined influence of negative-ion activation and HHO enrichment on the measured thermal response in improving the thermal performance of small-scale waste incineration.
Fig. 3
Transient temperature profiles measured at seven thermocouple locations under four operating conditions at 2 cm and 5.6 m³ h⁻¹: (a) Ion OFF, (b) Ion ON, (c) Ion OFF + HHO, and (d) Ion ON + HHO.
Major gas species distribution under ion assistance and HHO addition
Figure 4 presents the transient distributions of the major combustion gases, namely CO₂, CO, and O₂, at 2 cm and 5.6 m³ h⁻¹ under four operating conditions. Figure 4a represents the conventional Ion OFF case, Fig. 4b shows the effect of ion-field activation, Fig. 4c illustrates the influence of HHO addition without ion assistance, and Fig. 4d presents the combined operation of ion assistance with HHO addition. These profiles are important because CO₂, CO, and O₂ directly reflect the degree of carbon oxidation, oxygen utilization, combustion completeness, and post-combustion recovery.
In Fig. 4a, the Ion OFF case shows a strong but relatively unstable combustion response. CO₂ rises sharply during the active combustion period, while CO also appears with noticeable intensity. The simultaneous increase in CO₂ and CO indicates that carbonaceous volatiles are being oxidized, but not completely converted to CO₂. The O₂ profile shows a strong depletion during the same period, confirming rapid oxygen consumption in the reaction zone. However, the irregular behavior of CO and O₂ suggests non-uniform mixing and the presence of local oxygen-deficient regions. This means that, although the baseline combustion is active, part of the carbon conversion proceeds through incomplete oxidation pathways.
Fig. 4
Transient distributions of major gas species measured at 2 cm and 5.6 m³ h⁻¹ under four operating conditions: (a) Ion OFF, (b) Ion ON, (c) Ion OFF + HHO, and (d) Ion ON + HHO.
In Fig. 4b, the Ion ON condition exhibits a more controlled major-gas response than the baseline. CO formation is reduced while CO₂ remains pronounced during the principal combustion period, and the O₂ depletion/recovery sequence becomes smoother. These measured changes are consistent with charge-conditioned modification of near-inlet transport and improved oxygen–volatile contact12,13.
In Fig. 4c, HHO addition under Ion OFF operation produces a measurable modification of the major-gas response. CO₂ evolution becomes smoother and more sustained, while CO decreases relative to the untreated condition, demonstrating improved carbon oxidation in the H₂/O₂-enriched combustion environment.
In Fig. 4d, the combined Ion ON with HHO case provides the most favorable gas-species response. CO₂ formation remains strong during the active combustion stage, while CO persistence is minimized and O₂ depletion occurs in a more controlled manner. The rapid recovery of O₂ after the combustion period indicates that oxygen is consumed efficiently during oxidation without prolonged oxygen-starved behavior. This profile reflects a more complete and stable combustion process, where carbon-containing intermediates are rapidly converted and the reaction zone avoids excessive accumulation of partially oxidized species.
Overall, the combined Ion ON + HHO condition exhibited the strongest carbon-oxidation response, with reduced CO persistence, sustained CO₂ formation, and more controlled O₂ utilization.
Methane distribution behavior under ion assistance and HHO addition
Figure 5 presents the transient CH₄ concentration profiles measured at 2 cm and 5.6 m³ h⁻¹ under four operating modes. Figure 5a represents the conventional Ion OFF condition, Fig. 5b shows the effect of activating the ion field, Fig. 5c illustrates the influence of HHO addition without ion assistance, and Fig. 5d presents the combined operation of ion assistance with HHO addition. Methane is a key indicator of incomplete oxidation of volatile hydrocarbons; therefore, its transient behavior reflects the effectiveness of the combustion zone in converting light combustible fragments into fully oxidized products.
In Fig. 5a, the Ion OFF case shows the highest and sharpest CH₄ peaks during the active devolatilization stage. This behavior indicates that methane and light hydrocarbon fragments are released rapidly from the waste matrix, while the local oxidation capacity is not sufficient to convert them immediately. The abrupt peaks suggest unstable volatile release, non-uniform oxygen availability, and weak mixing between combustible gases and oxidizing species. Although CH₄ eventually decreases after the main combustion period, the high transient concentration confirms that the baseline condition allows significant hydrocarbon slip before complete burnout is achieved.
In Fig. 5b, activation of the ion source reduces the magnitude of the CH₄ peaks and produces a smoother concentration history relative to Ion OFF operation. The measured reduction in transient methane slip is consistent with improved contact between released volatiles and the oxidizing environment under electrical activation.
In Fig. 5c, HHO addition under Ion OFF operation decreases the CH₄ peak and makes the transient release less abrupt than under conventional operation. The measured lower methane persistence is consistent with enhanced oxidation in the H₂/O₂-enriched reaction environment.
In Fig. 5d, the Ion ON with HHO case shows the most favorable methane response. The CH₄ concentration is suppressed more effectively, and the transient profile becomes smoother and more controlled during the active combustion stage. This behavior indicates that methane release and oxidation become better synchronized: volatile hydrocarbons are generated, mixed, and oxidized more efficiently within the reaction zone. The combined condition therefore limits the accumulation of unburned methane and improves the post-peak decay behavior.
Together, these trends show that Ion ON + HHO most effectively reduced transient methane slip and improved volatile burnout among the investigated operating modes.
Fig. 5
Transient CH₄ concentration profiles measured at 2 cm and 5.6 m³ h⁻¹ under four operating conditions: (a) Ion OFF, (b) Ion ON, (c) Ion OFF + HHO, and (d) Ion ON + HHO.
Ethane distribution behavior under ion assistance and HHO addition
Figure 6 presents the transient C₂H₆ concentration profiles measured at 2 cm and 5.6 m³ h⁻¹ under the four investigated operating modes. Figure 6a represents the conventional Ion OFF condition, Fig. 6b shows the effect of activating the ion field, Fig. 6c illustrates the influence of HHO addition without ion assistance, and Fig. 6d presents the combined operation of ion assistance with HHO addition. Ethane is an important light-hydrocarbon indicator because its appearance in the exhaust reflects incomplete oxidation of volatile fragments released during waste devolatilization. Therefore, the C₂H₆ profile provides useful evidence about hydrocarbon slip, flame stability, oxidation completeness, and the effectiveness of the reaction zone in converting intermediate hydrocarbons into final oxidized products.
Fig. 6
Transient C₂H₆ concentration profiles measured at 2 cm and 5.6 m³ h⁻¹ under four operating conditions: (a) Ion OFF, (b) Ion ON, (c) Ion OFF + HHO, and (d) Ion ON + HHO.
In Fig. 6a, the Ion OFF case shows the highest and most irregular C₂H₆ release. The profile contains sharp transient peaks during the active combustion stage, indicating that volatile hydrocarbons are released faster than they can be oxidized. This behavior reflects weak control of the combustion field, non-uniform oxygen distribution, and the formation of localized fuel-rich pockets. The high C₂H₆ peaks also suggest that cracking and devolatilization products pass through the reaction zone without complete conversion. Although the concentration decreases after the main combustion period, the strong transient ethane release confirms that the baseline condition is associated with significant incomplete hydrocarbon oxidation.
In Fig. 6b, Ion ON operation reduces the C₂H₆ peak intensity and produces a more controlled transient profile relative to the untreated case. This directly demonstrates reduced ethane slip and is consistent with charge-associated modification of local flow and species transport12,13.
In Fig. 6c, HHO addition under Ion OFF operation further suppresses the measured C₂H₆ response. The lower peak and less severe transient release demonstrate improved light-hydrocarbon conversion under the investigated HHO-assisted condition.
In Fig. 6d, the Ion ON with HHO condition shows the most favorable C₂H₆ behavior. The ethane concentration is suppressed more effectively, and the post-peak decay becomes smoother and more stable. This response indicates that the production, transport, and oxidation of light hydrocarbons become better synchronized within the combustion zone. The combined condition limits the accumulation of ethane during active devolatilization and reduces the probability of hydrocarbon slip through the exhaust pathway.
Accordingly, the combined Ion ON + HHO condition provided the strongest C₂H₆ suppression and the most stable post-peak decay, indicating improved light-hydrocarbon conversion relative to the separate assistance modes.
HCN distribution behavior under ion assistance and HHO add
Figure 7 presents the transient HCN concentration profiles measured under the four investigated operating modes. HCN is an important intermediate in the conversion of fuel-bound nitrogen during MSW combustion. As reported in Table 1, the dry combustible/organic fraction of the tested MSW contained 0.2 wt% N, establishing the parent nitrogen inventory available for formation of reduced nitrogen intermediates and nitrogen oxides. During devolatilization, part of the fuel-bound nitrogen can enter the gas phase through nitrogen-containing fragments and subsequently form HCN or NH₃, particularly in locally fuel-rich and oxygen-deficient regions. Their subsequent conversion depends strongly on temperature, oxygen availability, residence time, mixing, and radical chemistry.
Because the same 2.0 kg feed loading, 30 mm characteristic particle-size class, and waste composition were applied to the four comparative operating modes, differences in the HCN profiles are interpreted primarily as changes in the conversion pathway of a common fuel-N inventory. This provides a stronger basis for assessing whether negative-ion assistance and HHO addition reduce the persistence of reduced nitrogen intermediates within the combustion system.
In Fig. 7a, the Ion OFF case shows the highest and most unstable HCN release. The profile contains sharp transient peaks during the active devolatilization and combustion stage, indicating rapid liberation of nitrogen-containing volatile fragments from the waste matrix. The high HCN intensity suggests that these intermediates are not oxidized efficiently before leaving the reaction zone. This behavior reflects weak flame control, non-uniform oxygen distribution, and the presence of local fuel-rich pockets where fuel-bound nitrogen can be converted into HCN rather than being further oxidized. The irregular peak structure also indicates unstable combustion chemistry and poor synchronization between volatile release and oxidation capacity.
Fig. 7
Transient HCN concentration profiles measured at 2 cm and 5.6 m³ h⁻¹ under four operating conditions: (a) Ion OFF, (b) Ion ON, (c) Ion OFF + HHO, and (d) Ion ON + HHO.
In Fig. 7b, activation of the ion source produces lower HCN peak intensity and a smoother transient profile relative to Ion OFF operation. Considering the common fuel-N inventory reported in Table 1, this measured difference demonstrates modified fuel-nitrogen conversion; improved oxygen–intermediate contact following altered near-inlet transport is a plausible explanation12,13.
In Fig. 7c, HHO addition under Ion OFF operation decreases the measured HCN intensity relative to the untreated condition, demonstrating that introduction of the H₂/O₂ co-feed modifies the conversion of fuel-nitrogen intermediates under the investigated conditions.
In Fig. 7d, the Ion ON with HHO condition shows the most favorable HCN behavior. The HCN concentration is suppressed more effectively, the transient peaks become less severe, and the decay behavior becomes smoother. This response indicates that nitrogen-containing volatile fragments are oxidized more efficiently during the active combustion period. The combined condition reduces the opportunity for HCN accumulation by improving both the chemical oxidation potential and the physical structure of the combustion zone.
Overall, Ion ON + HHO produced the lowest and smoothest HCN response, indicating reduced persistence of fuel-N intermediates under the coupled condition.
NO and average nitrogen containing species under ion assistance and HHO addition
Figure 8 presents the transient NO concentration profiles measured at 2 cm and 5.6 m³ h⁻¹ under the four investigated operating modes, while Fig. 9 summarizes the corresponding average concentrations of the main nitrogen-containing species, including N₂O, NO, NO₂, NH₃, and HCN. Figure 8a represents the conventional Ion OFF condition, Fig. 8b shows the influence of ion-field activation, Fig. 8c illustrates the effect of HHO addition without ion assistance, and Fig. 8d presents the combined operation of ion assistance with HHO addition. Together, these figures provide a comprehensive interpretation of nitrogen conversion during waste combustion, because the transient NO profiles reflect instantaneous nitrogen-oxide formation, whereas the average concentration data reveal the overall conversion behavior of fuel-bound nitrogen intermediates.
The initial nitrogen basis is particularly important when comparing the NO response. With a fuel-bound nitrogen content of 0.2 wt% and a consistent 2.0 kg feed loading (Table 1), the nominal nitrogen input was held constant among the four operating conditions. Therefore, the observed differences in NO and the accompanying HCN/NH₃ behavior represent changes in the partitioning and conversion of fuel nitrogen under different thermal, mixing, and chemical reaction environments, rather than changes in the amount of nitrogen introduced with the waste. This interpretation is consistent with established fixed-bed MSW combustion studies showing that fuel-N conversion responds strongly to local combustion conditions5,20.
In Fig. 8a, the conventional Ion OFF condition exhibits the strongest and most irregular transient NO excursions during the active combustion period. This baseline behavior is consistent with localized high-temperature reaction zones and heterogeneous oxygen availability during devolatilization.
In Fig. 8b, activation of the ion source reduces the magnitude and abruptness of the transient NO peaks. Together with the temperature histories, the direct measurements show fewer intense thermal and NO excursions than under the baseline condition; charge-induced modification of flame structure and gas transport provides a plausible explanation12,13.
In Fig. 8c, HHO addition under Ion OFF operation reduces the measured NO response relative to the untreated baseline, demonstrating modification of the nitrogen-conversion environment following introduction of the H₂/O₂ co-feed.
In Fig. 8d, the combined Ion ON + HHO condition shows the most controlled NO profile, with suppressed transient peaks and a smoother emission response. The result indicates complementary modification of the chemical oxidation environment and combustion stability under coupled operation.
Fig. 8
Transient NO concentration profiles measured at 2 cm and 5.6 m³ h⁻¹ under four operating conditions: (a) Ion OFF, (b) Ion ON, (c) Ion OFF + HHO, and (d) Ion ON + HHO.
Figure 9 strengthens this interpretation by showing that the combined Ion ON with HHO condition gives the lowest overall average concentrations of the principal nitrogen-containing species. The reduction is especially clear for HCN and NH₃, which are important reduced nitrogen intermediates associated with incomplete conversion of fuel-bound nitrogen. Lower HCN indicates that nitrogen-containing volatiles are more effectively oxidized before accumulating as toxic intermediate species, while lower NH₃ reflects improved conversion of reduced nitrogen fragments. The lower NO average concentration also confirms that nitrogen-oxide formation is controlled without shifting the system toward excessive NO production.
The combined Ion ON + HHO condition therefore produces the most favorable measured nitrogen-species response among the investigated operating modes. The simultaneous reduction of HCN and NH₃ together with NO and NO₂ indicates improved conversion of the common fuel-N inventory without a corresponding increase in nitrogen-oxide formation. The detailed chemical interpretation of this behavior, including the possible role of NCO/NHx-mediated N₂-forming pathways, is discussed in Sect. 3.6.1.
Fig. 9
Average concentrations of N-containing species measured at 2 cm and 5.6 m³ h⁻¹ under Ion OFF, Ion ON, Ion OFF + HHO, and Ion ON + HHO conditions.
Interpretation of the fuel-nitrogen conversion route under coupled ion-HHO operation
The simultaneous behavior of HCN, NH₃, NO, NO₂, and N₂O provides additional insight into the fate of fuel-bound nitrogen under the coupled condition. The parent MSW contained 0.2 wt% nitrogen on the reported dry combustible/organic basis, and the same feed preparation and loading were maintained among the four operating modes. Consequently, the decrease in the measured nitrogen-containing species reflects a modification of nitrogen partitioning rather than a decrease in the initial nitrogen inventory.
During devolatilization of heterogeneous solid fuels, volatile fuel nitrogen can enter the gas phase through reduced intermediates dominated by HCN, NH₃, and related nitrogen-containing fragments. Their subsequent conversion is governed by competing pathways toward NOx or molecular N₂. Detailed nitrogen-chemistry studies show that HCN oxidation can proceed through CN and particularly NCO intermediates, whereas NH₃ is converted primarily through NH₂, NH, and related NHx species22,23,24. NCO is an important branching intermediate because its reaction sequence can either propagate toward NO or remove NO through N–N-forming pathways, depending on temperature, oxygen availability, and the surrounding radical and species concentrations.
Representative literature-supported pathways can be expressed schematically as.
$$\:\text{F}\text{u}\text{e}\text{l}-\text{N}\to\:\text{H}\text{C}\text{N},\text{}\text{N}{\text{H}}_{3},\text{}\text{o}\text{t}\text{h}\text{e}\text{r}\text{}\text{r}\text{e}\text{d}\text{u}\text{c}\text{e}\text{d}\text{}\text{N}\text{}\text{s}\text{p}\text{e}\text{c}\text{i}\text{e}\text{s}$$
(11)
$$\:\text{H}\text{C}\text{N}+\text{O}\text{H}\to\:\text{C}\text{N}+{\text{H}}_{2}\text{O}$$
(12)
$$\:\text{C}\text{N}+{\text{O}}_{2}\to\:\text{N}\text{C}\text{O}+\text{O}$$
(13)
followed by competing branches such as
$$\:\text{N}\text{C}\text{O}+\text{O}\to\:\text{N}\text{O}+\text{C}\text{O}$$
(14)
and
$$\:\text{N}\text{C}\text{O}+\text{N}\text{O}\to\:{\text{N}}_{2}+\text{C}{\text{O}}_{2}$$
(15)
or
$$\:\text{N}\text{C}\text{O}+\text{N}\text{O}\to\:{\text{N}}_{2}\text{O}+\text{C}\text{O}$$
(16)
with subsequent reduction of N₂O, for example,
$$\:{\text{N}}_{2}\text{O}+\text{H}\to\:{\text{N}}_{2}+\text{O}\text{H}$$
(17)
The NH₃ branch similarly begins through H-abstraction,
$$\:\text{N}{\text{H}}_{3}+\text{O}\text{H}\to\:\text{N}{\text{H}}_{2}+{\text{H}}_{2}\text{O}$$
(18)
after which NHx species can follow competing oxidation and NO-reduction routes. An important N₂-forming pathway is represented schematically by
$$\:\text{N}{\text{H}}_{2}+\text{N}\text{O}\to\:{\text{N}}_{2}+{\text{H}}_{2}\text{O}$$
(19)
Thus, conversion of HCN or NH₃ does not necessarily imply their quantitative oxidation to NO. Their nitrogen atoms can be transferred through NCO/NHx chemistry into either oxidized nitrogen species or N₂-forming pathways. The balance among these branches is strongly dependent on local stoichiometry, temperature, residence time, and reactive-species concentrations22,23,24. HCN oxidation through NCO and the competition between NCO-to-NO and NCO/NO-to-N₂/N₂O routes are well established, while NHx–NO chemistry provides an additional pathway for removal of NO as molecular nitrogen22,23,24.
The experimental trends observed here are particularly informative because HCN and NH₃ decrease simultaneously with NO and NO₂ under the coupled Ion ON + HHO condition. If suppression of the reduced nitrogen intermediates occurred predominantly through increased oxidation to NO, a corresponding increase in NO or total NOx would be expected. Instead, total NOx decreases from approximately 70.0 ppm under Ion OFF to 49.3 ppm under Ion ON + HHO, a reduction of approximately 29.6%. The measured response therefore indicates that enhanced consumption of HCN and NH₃ is not accompanied by increased accumulation of NOx.
A chemically plausible interpretation is that the coupled condition shifts the net fuel-N partitioning away from both persistent reduced intermediates and NOx-forming branches and increases the relative importance of N–N recombination and NO-reduction pathways terminating in N₂. Negative-ion activation is experimentally associated with smoother thermal behavior and reduced transient emission peaks and may improve spatial contact between oxygen and volatile nitrogen fragments, thereby limiting strongly fuel-rich pockets. HHO enrichment produces an additional experimentally observed change in the chemical-conversion environment. Established H₂/O₂ chemistry involving H, O, OH, HO₂, and related species can influence the competition between oxidation and NO-reduction pathways; however, these radicals were not directly measured in the present experiments and their role is therefore considered mechanistic rather than experimentally demonstrated.
Importantly, the present data do not directly establish a quantitative fuel-N-to-N₂ selectivity. Molecular nitrogen was not resolved as a fuel-derived product, and direct determination is difficult in an air-fired reactor because N₂ is already the dominant constituent of the incoming combustion air. The simultaneous reductions in HCN, NH₃, NO, NO₂, and total NOx are therefore interpreted as being consistent with enhanced partitioning toward N₂-forming routes, rather than as direct proof of preferential N₂ formation. A definitive nitrogen balance would require measurement of all relevant nitrogen products and, preferably, isotopic tracing using a labelled fuel-N source.
NO–NO₂ interconversion and total-NOx behavior
Interpretation of the transient NO response requires consideration of NO₂ because a reduction in NO does not necessarily represent removal of nitrogen oxides if NO is simply oxidized to NO₂. This distinction is particularly important in combustion systems because NO and NO₂ participate in a reversible reaction network whose direction depends on temperature, oxygen availability, radical concentrations, residence time, and mixing between hot combustion products and cooler oxidizing gas22,25.
One important NO₂-forming pathway is
$$\:\text{N}\text{O}+\text{H}{\text{O}}_{2}\to\:\text{N}{\text{O}}_{2}+\text{O}\text{H}$$
which is favored in comparatively cooler combustion/post-combustion regions containing appreciable HO₂. Formation of HO₂ is promoted as reactive hydrogen and oxygen chemistry evolves toward lower-temperature post-flame conditions. Consequently, the H₂/O₂-enriched environment introduced by HHO makes consideration of the NO–NO₂ interconversion particularly relevant, although HO₂ concentrations were not measured directly in the present experiments. Classical combustion studies have shown that NO-to-NO₂ conversion can become significant during rapid cooling or mixing of burned gas with excess air25.
NO₂ is not necessarily a terminal product and can be converted back to NO through reactions such as \(\:\text{N}{\text{O}}_{2}+\text{H}\to\:\text{N}\text{O}+\text{O}\text{H}\) and \(\:\text{N}{\text{O}}_{2}+\text{O}\to\:\text{N}\text{O}+{\text{O}}_{2}\).
while additional NO/NO₂ reaction channels depend on the local chemical environment. The measured NO and NO₂ concentrations should therefore be interpreted as the net outcome of continuing interconversion rather than as independently formed species.
The experimental results in Fig. 9 provide an important distinction in this respect. Although the average NO concentration decreases progressively from Ion OFF to Ion ON + HHO, the NO₂ concentration does not increase correspondingly. Instead, NO₂ also decreases under the assisted conditions. Thus, the decrease in NO cannot be explained predominantly by simple oxidation of NO to NO₂.
To quantify the total oxidized-nitrogen response, conventional total NOx was calculated as \(\:\text{N}{\text{O}}_{\text{x}}=\text{N}\text{O}+\text{N}{\text{O}}_{2},\) while N₂O was retained separately because it represents a chemically distinct nitrogen-containing species. Total NOx decreased progressively across the assisted conditions relative to Ion OFF, with the largest reduction under Ion ON + HHO. This confirms that the lower NO response reflects a decrease in the measured NO + NO₂ burden rather than redistribution from NO toward NO₂.
The total-NOx response should be interpreted together with HCN, NH₃, and N₂O. Fuel-bound nitrogen released during devolatilization can initially form HCN, NH₃, and related reduced fragments. HCN conversion can proceed through CN and NCO intermediates, whereas NH₃ conversion proceeds primarily through NH₂, NH, HNO, and related NHx species22,23,24. These reaction families contain both NO-forming and NO-consuming branches. NCO, for example, may be oxidized toward NO or react with NO through N–N-forming pathways leading to N₂ and N₂O. Likewise, NH₂ and NH can react with NO through pathways that form N₂ or N₂O, while other oxidative branches regenerate NO22,23,24.
The nitrogen-conversion network under coupled Ion ON + HHO operation can therefore be represented conceptually as \(\:\text{F}\text{u}\text{e}\text{l}-\text{N}\to\:\text{H}\text{C}\text{N}/\text{N}{\text{H}}_{3}\to\:\text{C}\text{N}/\text{N}\text{C}\text{O}/\text{N}{\text{H}}_{\text{x}}\), followed by competing pathways toward \(\:\text{N}\text{O}\rightleftharpoons\:\text{N}{\text{O}}_{2}\), \(\:{\text{N}}_{2}\text{O}\), or \(\:{\text{N}}_{2}\).
The experimental significance of the coupled condition is that HCN and NH₃ decrease simultaneously with NO and NO₂ rather than being accompanied by increased oxidized nitrogen. This behavior indicates that improved consumption of reduced fuel-N intermediates is not simply transferring nitrogen into NO₂ or total NOx. Instead, the measured data are consistent with redistribution of fuel nitrogen toward pathways that reduce the persistence of both reduced nitrogen intermediates and NOx. N₂-forming chemistry provides a plausible terminal pathway, but direct quantitative N₂ selectivity cannot be established because fuel-derived N₂ was not independently distinguished from the large atmospheric-N₂ background.
Negative-ion activation may contribute by modifying near-inlet transport and reducing strongly heterogeneous fuel-rich and oxygen-deficient regions, while HHO addition modifies the chemical oxidation environment. These influences may alter the competition among HCN/NH₃ oxidation, NO formation, NO-to-NO₂ conversion, and NO-consuming N₂-forming reactions. However, the local ion field and H/O/OH/HO₂ concentrations were not directly measured. The experimentally supported conclusion is therefore limited to the observed reduction in the combined nitrogen-pollutant burden, while the detailed reaction sequence remains mechanistic interpretation.
Sulfur-emission behavior under ion assistance and HHO addition
Figure 10 presents the transient SO₂ concentration profiles under Ion OFF, Ion ON, Ion OFF + HHO, and Ion ON + HHO operation. The sulfur response should be interpreted relative to the sulfur inventory of the parent waste. As reported in Table 1, the dry combustible/organic fraction contained 0.2 wt% S. Because the same waste composition and 2.0 kg feed loading were used for the four comparative operating modes, the nominal sulfur input was maintained consistently among the tests. Accordingly, differences in the transient SO₂ profiles are interpreted in terms of changes in sulfur release, oxidation, gas-phase transport, and potential interaction with the solid/mineral phase under the different combustion environments, rather than differences in the sulfur concentration of the feed.
Fig. 10
Transient SO₂ concentration profiles measured at 2 cm and 5.6 m³ h⁻¹ under four operating conditions: Ion OFF, Ion ON, Ion OFF + HHO, and Ion ON + HHO.
Sulfur dioxide is produced principally following oxidation of sulfur-containing compounds released during thermal conversion. Its instantaneous concentration can therefore depend not only on total fuel sulfur but also on the temporal rate of sulfur release, local temperature, oxygen availability, mineral interactions, and gas residence behavior. The 0.2 wt% sulfur value reported in Table 1 provides the necessary feedstock basis for interpreting the relative SO₂ response of the four operating modes.
In the Ion OFF condition, the SO₂ curve shows the highest concentration level and the most pronounced emission peak. The sharp increase during the active combustion period indicates rapid sulfur release followed by strong oxidation in localized reaction zones. The relatively high post-peak tail also suggests that sulfur-containing fragments continue to be released or oxidized during the burnout stage. This behavior reflects a less controlled combustion environment, where local hot spots, uneven oxygen availability, and non-uniform mixing promote unstable SO₂ formation.
When the ion field is activated, the SO₂ profile decreases noticeably compared with Ion OFF. The lower peak and reduced late-stage concentration indicate that ion assistance improves the stability of the combustion zone. This improvement can be attributed to enhanced charged-species transport, better local mixing, and more uniform oxygen distribution around sulfur-containing volatiles. As a result, sulfur oxidation becomes less dominated by sudden localized bursts, and the SO₂ release pattern becomes more controlled during both the active combustion and burnout periods.
Under Ion OFF with HHO, the SO₂ concentration is further suppressed. The main peak becomes substantially lower than the untreated Ion OFF condition, showing that HHO addition modifies the chemical environment of combustion. Under Ion OFF + HHO operation, the measured SO₂ concentration decreases relative to the conventional baseline. The lower peak demonstrates that introduction of the H₂/O₂ co-feed modifies the transient sulfur-emission response. Because the sulfur input was maintained consistently among the comparative cases, this difference may reflect changes in combustion intensity, sulfur-release timing, oxidation conditions, transport, and gas–solid partitioning. The present measurements do not resolve a sulfur-specific H/O/OH radical pathway, and the observed SO₂ reduction is therefore reported as an experimental system response rather than being uniquely attributed to radical chemistry.
The Ion ON with HHO condition shows the lowest SO₂ response over the full transient period. The main peak is strongly reduced, and the post-peak tail remains lower than in the other operating modes. This behavior indicates that sulfur emission control is improved not only during the main volatile-release stage but also during the later burnout stage. The smoother and lower SO₂ curve confirms that the combined operation provides a more stable and more uniform sulfur-conversion environment.
Overall, Ion ON + HHO produced the lowest and smoothest SO₂ response among the investigated modes, while the detailed sulfur-conversion pathway remains unresolved by the present measurements.
Experimental environmental co-pollutant assessment
The environmental assessment was extended beyond the continuously monitored major combustion gases to include experimentally determined particulate matter (PM), volatile organic compounds (VOCs), HCl, and polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). These measurements provide an important complement to the temperature, CO/CO₂/O₂, CH₄, C₂H₆, nitrogen-species, and SO₂ results because they address pollutant classes directly relevant to the environmental performance of small-scale MSW incineration. PM was determined from the stack-gas particulate measurement described in Sect. 2.9.1, HCl was quantified after alkaline absorption as described in Sect. 2.9.2, VOCs were measured independently of the CH₄ and C₂H₆ channels according to Sect. 2.9.3, and PCDD/Fs were determined by congener-specific HRGC/HRMS following the procedure described in Sect. 2.9.4.
For comparison among the four operating modes, the experimentally determined PM, VOC, HCl, and PCDD/F responses were additionally expressed relative to the corresponding Ion OFF value, which was normalized to 100. This normalization is used only to facilitate comparison among pollutant classes having different physical units and concentration ranges; it does not represent a model prediction or semi-empirical estimate. Total NOx was calculated separately from the experimentally determined average NO and NO₂ concentrations. The results are summarized in Table 7 and presented individually in Figs. 11, 12, 13, 14 and 15.
Table 7 Experimentally determined total NOx and normalized measured co-pollutant responses under the four combustion modes.
The results in Table 7 show that the influence of negative-ion and HHO assistance differs among pollutant classes. The strongest reductions under combined operation occur for PM, VOCs, total NOx, and PCDD/Fs, whereas HCl exhibits a considerably smaller response. This distinction is important because combustion-derived pollutants are strongly influenced by oxidation completeness and transient combustion behavior, while acid-gas release is additionally constrained by the chlorine inventory and gas–solid partitioning of the waste.
Total NOx response
The total nitrogen-oxide response was evaluated from the experimentally determined average NO and NO₂ concentrations. Conventional total NOx was defined on a volumetric basis as
$$\:N{O}_{x}=NO+N{O}_{2}$$
(20)
where N₂O was retained as a separate nitrogen-containing species and was not included in the conventional NOx quantity.
The calculated average total NOx concentrations were approximately 70.0, 62.4, 55.8, and 49.3 ppm for Ion OFF, Ion ON, Ion OFF + HHO, and Ion ON + HHO, respectively. Relative to conventional Ion OFF operation, activation of the negative-ion source decreased total NOx by approximately 10.9%, HHO addition decreased it by approximately 20.3%, and combined Ion ON + HHO operation produced the largest decrease of approximately 29.6%. The comparison is shown in Fig. 11.
The progressive decrease in total NOx is consistent with the individual nitrogen-species behavior discussed in Sect. 3.6. Importantly, both NO and NO₂ decrease under the assisted conditions, indicating that the reduction in total NOx is not produced merely by redistribution between the two principal nitrogen oxides. The concurrent decrease in HCN and NH₃ further shows that lower NOx is accompanied by reduced accumulation of important reduced fuel-N intermediates.
The combined mode therefore provides the most favorable experimentally observed nitrogen-emission response under the investigated conditions. Changes in temperature history, oxygen availability, volatile conversion, and fuel-N pathways may contribute, but the detailed elementary mechanism is not resolved by the present concentration measurements.
Fig. 11
Average total NOx concentration, calculated as NO + NO₂ from the experimentally determined nitrogen-species concentrations, under Ion OFF, Ion ON, Ion OFF + HHO, and Ion ON + HHO operation.
Experimental particulate-matter response
Particulate matter was measured directly in the stack gas under the four investigated operating conditions using the sampling procedure described in Sect. 2.9.1. Because the feed loading, characteristic particle size, airflow, sampling configuration, and operating procedure were maintained consistently among the four cases, the measured PM response provides a direct experimental indication of the influence of the combustion-assistance mode on particulate release.
Relative to the Ion OFF baseline normalized to 100, the measured PM response decreased to approximately 84.1 under Ion ON, 72.3 under Ion OFF + HHO, and 69.4 under Ion ON + HHO. These values correspond to reductions of approximately 15.9%, 27.7%, and 30.6%, respectively. The combined Ion ON + HHO condition therefore produced the lowest measured particulate response among the four investigated modes. The comparison is shown in Fig. 12.
Fig. 12
Experimentally measured particulate-matter response under Ion OFF, Ion ON, Ion OFF + HHO, and Ion ON + HHO operation, normalized to the Ion OFF value. Error bars represent the experimental variability or measurement uncertainty associated with the reported values.
The PM reduction follows the general improvement observed in CO, CH₄, and C₂H₆ and is therefore consistent with reduced generation or persistence of combustion-derived soot and condensable organic particulate precursors. At the same time, the parent MSW contains a substantial ash fraction, so the measured PM includes contributions that may arise from both combustion-generated material and entrained mineral particles. Ionization may also modify the transport, agglomeration, migration, or deposition behavior of electrically charged particulate matter, but these particle-scale processes were not independently measured. Consequently, the experimentally demonstrated conclusion is the decrease in stack PM response, whereas the detailed particle-transport mechanism remains unresolved.
The approximately 30.6% decrease obtained under Ion ON + HHO is environmentally important because it demonstrates that the favorable combustion response is accompanied by a measurable reduction in particulate emissions rather than only by changes in gaseous incomplete-combustion products.
Experimental VOC emission response
VOCs were measured independently of CH₄ and C₂H₆, as described in Sect. 2.9.3. This distinction is important because the individual light-hydrocarbon channels characterize only selected volatile species, whereas the VOC measurement provides a broader assessment of organic material escaping complete oxidation.
The normalized experimental VOC response decreased from 100 under Ion OFF operation to approximately 88.9 under Ion ON, 63.1 under Ion OFF + HHO, and 69.2 under Ion ON + HHO. These changes correspond to reductions of approximately 11.1%, 36.9%, and 30.8%, respectively. The comparison is shown in Fig. 13.
The strong reduction observed in the two HHO-assisted cases is consistent with the simultaneously lower CH₄, C₂H₆, and CO responses and indicates that HHO addition modifies the oxidation environment beyond the conversion of only the two individually monitored light hydrocarbons. The lowest central VOC response occurs for Ion OFF + HHO rather than Ion ON + HHO. This observation is important and indicates that the operating condition producing the best response for an individual pollutant does not necessarily provide the strongest integrated performance across all measured variables.
The combined Ion ON + HHO condition nevertheless reduces VOC emissions by approximately 30.8% relative to the conventional baseline while simultaneously producing the lowest total NOx and PM responses and the most controlled overall thermal behavior. Therefore, its advantage is better interpreted in terms of simultaneous thermal and multi-pollutant performance rather than as the absolute minimum for every individual species.
The VOC decrease is consistent with improved oxidation of volatile organic material under the HHO-containing conditions, while the detailed reactive pathway remains unresolved by the present measurements.
Fig. 13
Experimentally measured VOC response under Ion OFF, Ion ON, Ion OFF + HHO, and Ion ON + HHO operation, normalized to the Ion OFF value. Error bars represent the experimental variability or measurement uncertainty associated with the reported values.
Experimental HCl emission response
HCl was experimentally quantified because chlorine represented approximately 0.9 wt% of the parent MSW. Since the same waste composition and loading were employed for all four operating modes, the initial chlorine inventory was held constant, allowing differences in stack HCl concentration to be attributed to changes in chlorine release and partitioning during combustion rather than to differences in the amount of chlorine introduced with the feed.
Relative to the Ion OFF value normalized to 100, the measured HCl response decreased to approximately 96.8 under Ion ON, 94.5 under Ion OFF + HHO, and 93.9 under Ion ON + HHO. These changes correspond to reductions of approximately 3.2%, 5.5%, and 6.1%, respectively. The comparison is shown in Fig. 14.
The HCl response is clearly smaller than the changes observed for PM, VOCs, and total NOx. This result is scientifically meaningful because HCl formation is strongly constrained by the chlorine inventory of the feed and by chlorine partitioning among gaseous HCl, inorganic chlorides, ash-associated chlorine, and other chlorine-containing species. Improving combustion completeness therefore cannot be expected to suppress HCl to the same extent as pollutants originating primarily from incomplete oxidation.
The lowest HCl response was nevertheless obtained under combined Ion ON + HHO operation, with a measured reduction of approximately 6.1% relative to Ion OFF. This modest decrease suggests that the modified combustion environment influences chlorine release or gas–solid partitioning to some extent, but the coupled system should not be regarded as a replacement for dedicated acid-gas control. Downstream alkaline sorption or other appropriate HCl-removal technologies would remain necessary where stringent emission limits apply.
Fig. 14
Experimentally measured HCl response under Ion OFF, Ion ON, Ion OFF + HHO, and Ion ON + HHO operation, normalized to the Ion OFF value. Error bars represent the experimental variability or measurement uncertainty associated with the reported values.
Experimental PCDD/F emission response
PCDD/Fs were experimentally determined through representative stack sampling followed by extraction, cleanup, and congener-specific HRGC/HRMS analysis. The seventeen toxicologically relevant 2,3,7,8-substituted congeners were incorporated into the toxic-equivalent evaluation, as described in Sect. 2.9.4. Therefore, unlike a precursor-based formation index, the present PCDD/F response represents an experimentally determined chlorinated-organic emission endpoint.
The normalized PCDD/F response decreased from 100 under Ion OFF operation to approximately 87.2 under Ion ON, 70.3 under Ion OFF + HHO, and 71.4 under Ion ON + HHO. These values correspond to reductions of approximately 12.8%, 29.7%, and 28.6%, respectively. The comparison is shown in Fig. 15.
Fig. 15
Experimentally determined PCDD/F response under Ion OFF, Ion ON, Ion OFF + HHO, and Ion ON + HHO operation, normalized to the Ion OFF value. Error bars represent the experimental variability or analytical uncertainty associated with the measurements.
Both HHO-containing conditions therefore produced substantially lower PCDD/F emissions than conventional Ion OFF operation, whereas negative-ion activation alone produced a smaller but still measurable decrease. The very similar responses of Ion OFF + HHO and Ion ON + HHO indicate that HHO addition exerts the stronger influence on this particular pollutant class, while the principal advantage of combined operation lies in its broader simultaneous control of thermal instability, NOx, PM, HCl, and other combustion-related emissions.
The measured PCDD/F decrease is consistent with modification of precursor availability and the combustion/post-combustion environment, but it cannot be assigned uniquely to a single radical-mediated or ion-induced mechanism.
Taken together, the extended experimental pollutant assessment demonstrates that the improvements observed in the thermal and continuously monitored gas-species responses are accompanied by measurable reductions across a broader environmental spectrum. Relative to conventional Ion OFF operation, combined Ion ON + HHO operation decreased total NOx by approximately 29.6%, particulate matter by 30.6%, VOC emissions by 30.8%, HCl by 6.1%, and PCDD/F emissions by 28.6%. The magnitude of the response differs among pollutant classes, with particularly strong reductions for PM, VOCs, NOx, and PCDD/Fs and a smaller response for chlorine-derived HCl. These results demonstrate that the environmental benefit of the coupled system extends beyond the suppression of individual light hydrocarbons or gaseous combustion intermediates and is observable across several experimentally determined pollutant classes.
The results also show that no single assistance mode is uniformly superior for every individual pollutant. HHO-only operation produces the lowest central VOC and PCDD/F responses, whereas combined Ion ON + HHO gives the lowest total NOx, PM, HCl, and overall thermal response. Consequently, the principal advantage of the coupled configuration is its integrated multi-pollutant and combustion-stability performance, rather than the assumption that it must minimize every individual emission independently.
Auxiliary electrical demand and energy penalty
The combustion and emission benefits should be evaluated together with the auxiliary electrical demand of the negative-ion generator and HHO electrolyzer. Their operating characteristics are summarized in Tables 2 and 3, while Table 8 reports the corresponding electrical-energy requirement and normalized penalty.
Table 8 Electrical-energy demand and normalized energy penalty of the combustion-assistance systems under the investigated operating conditions.
As shown in Table 8, HHO electrolysis constituted the dominant auxiliary electrical load, whereas the negative-ion generator contributed only a very small fraction of the total electrical requirement. The combined Ion ON + HHO condition required less than approximately 0.045–0.089 kWh during the approximately 1 h experimental period, equivalent to approximately 0.42–0.82% of the nominal 10.83 kWh chemical-energy content of the 2.0 kg MSW batch. This comparison quantifies the auxiliary electrical penalty but should not be interpreted as a complete net-energy efficiency because useful heat recovery and the remaining plant auxiliary loads are not included.
These results show that the auxiliary electricity required under the investigated laboratory conditions was small relative to the nominal chemical-energy inventory of the 2.0 kg waste batch. However, this ratio should not be interpreted as a net energy-efficiency value. The LHV-based energy inventory represents the chemical energy contained in the waste and is not equivalent to the useful thermal energy recovered by the incineration system. A complete net-energy balance would additionally require measurement of combustion efficiency, residual carbon in the ash, heat-transfer efficiency, useful heat recovery, sensible and latent flue-gas losses, wall losses, combustion-air and exhaust-fan electricity, and the electrical demand of any downstream flue-gas-treatment equipment.
The energy penalty must also be considered together with the experimentally observed environmental benefits. Under the combined Ion ON + HHO condition, the system exhibited the most favorable overall balance of thermal stabilization and multi-pollutant control within the investigated operating window, including substantial reductions in total NOx, particulate matter, VOCs, and PCDD/F emissions. The present energy analysis therefore demonstrates that these combustion and emission changes were obtained with an auxiliary electrical requirement below approximately 0.83% of the nominal MSW chemical-energy input. Nevertheless, this comparison alone cannot establish economic viability because the monetary value of the environmental and thermal benefits depends on plant-scale operating conditions and the corresponding energy-recovery and pollutant-control systems.
For preliminary economic interpretation, the direct electricity cost of the assistance systems may be expressed as
$$\:{C}_{\text{e}\text{l}}={c}_{\text{e}\text{l}}{E}_{\text{a}\text{s}\text{s}\text{i}\text{s}\text{t}}$$
where \(\:{c}_{\text{e}\text{l}}\) is the applicable electricity tariff. For the combined condition, the direct auxiliary electricity cost per approximately 1 h experimental batch is therefore
$$\:{C}_{\text{e}\text{l}}={c}_{\text{e}\text{l}}\left(0.045-0.089\right)$$
This formulation allows the electrical operating cost to be evaluated for any regional tariff without introducing a location-dependent electricity-price assumption into the present study. However, a complete cost-benefit analysis must extend beyond electricity consumption and incorporate electrolyzer and ionizer capital costs, power electronics, water and electrolyte consumption, electrode replacement, component lifetime, maintenance requirements, flashback-protection and safety equipment, useful heat or electricity recovery, waste-processing throughput, and potential reductions in downstream pollutant-control requirements.
Accordingly, the present results demonstrate that the laboratory-scale auxiliary electrical penalty is quantitatively modest, with the negative-ion generator contributing a negligible fraction and HHO generation accounting for the dominant electrical requirement. The coupled Ion ON + HHO condition can therefore be identified as the most favorable measured thermal and emission operating condition within the investigated experimental window, but it should not yet be described as an economically optimized or deployment-ready configuration. Pilot-scale energy recovery measurements, long-duration electrolyzer and ionizer durability testing, full plant auxiliary-power accounting, and a dedicated techno-economic analysis are required before practical implementation can be evaluated conclusively.
Integrated assessment of ion-assisted HHO combustion performance
The integrated comparison is restricted to the investigated 2.0 kg MSW batch, approximately 30 mm particle-size class, 5.6 m³ h⁻¹ airflow, specified HHO operating range, fixed negative-ion setting, and reported sampling configuration; it should not be interpreted as a universal optimum.
Across the thermal and carbon/hydrocarbon measurements, negative-ion activation was primarily associated with improved transient stability, whereas HHO addition was associated with stronger oxidation of CO and volatile intermediates. Their combination produced the most balanced thermal response together with reduced CO, CH₄, and C₂H₆ persistence.
The nitrogen and sulfur measurements show the same integrated tendency: assisted operation lowered the measured fuel-N intermediates and nitrogen-oxide burden, and Ion ON + HHO produced the lowest overall SO₂ response. These observations describe measured species responses and do not establish quantitative N₂ selectivity or sulfur removal.
The broader pollutant measurements reinforce the trade-off interpretation. HHO-only operation produced slightly lower central VOC and PCDD/F responses, whereas Ion ON + HHO produced the lowest total NOx, PM, and HCl responses together with the most favorable overall thermal behavior. The coupled condition is therefore preferred for integrated multi-response performance rather than universal minimization of every pollutant.
The physical and chemical mechanisms remain interpretive: charge-assisted transport/electrohydrodynamic effects and H₂/O₂ reaction chemistry are consistent with the observations but were not directly quantified inside the reacting chamber.
From an energy perspective, the negative-ion generator contributed only a minor auxiliary load, while HHO electrolysis dominated the electrical demand; the combined requirement remained below approximately 0.83% of the nominal MSW chemical-energy input. Overall, Ion ON + HHO was the most favorable integrated condition within the investigated laboratory window, while optimization, economics, and scale-up remain subjects for future work.
Limitations, applicability range, and future work
The conclusions of this study are bounded by the experimental and analytical conditions under which the four combustion modes were compared. All experiments employed a 2.0 kg MSW batch, an approximately 30 mm characteristic particle-size class, a combustion-air flow rate of 5.6 m³ h⁻¹, one investigated HHO operating range, one fixed negative-ion-source condition, and the reported sampling configuration. Maintaining these parameters consistently was necessary to isolate the effects of Ion OFF, Ion ON, Ion OFF + HHO, and Ion ON + HHO operation. However, the resulting performance ranking applies only to this experimental envelope and should not be extrapolated directly to different waste compositions, loading rates, bed depths, particle sizes, airflow rates, reactor geometries, HHO dosages, ion intensities, or plant scales.
A first limitation concerns the combustion-air condition. The constant volumetric airflow used in the comparative experiments does not constitute a systematic investigation of excess-air ratio. During batch MSW combustion, instantaneous oxygen demand varies continuously during drying, devolatilization, flaming combustion, char oxidation, and burnout. Consequently, a fixed supplied airflow does not imply a fixed instantaneous excess-air ratio throughout the combustion cycle. The present experiments therefore establish the comparative behavior at 5.6 m³ h⁻¹ but do not identify an optimum air ratio. Future work should vary primary and, where applicable, secondary air independently and quantify the time-dependent excess-air ratio together with combustion-front propagation, O₂ distribution, temperature uniformity, burnout, and pollutant formation.
A second limitation concerns HHO dosage. The electrolyzer was operated at 2.2 V and 20–40 A, with HHO production rates of approximately 13.7–27.4 NL h⁻¹, but the combustion campaign was not designed as a systematic HHO-dose-response optimization. The present results therefore demonstrate the response within this HHO operating range rather than identifying an optimum HHO-to-air or HHO-to-fuel ratio. Increasing HHO supply should not be assumed to produce proportionally greater improvement because hydrogen/oxygen enrichment can modify flame propagation, local heat release, oxygen distribution, nitrogen chemistry, and parasitic electrical demand. Future experiments should therefore evaluate several controlled HHO dosages while simultaneously measuring combustion performance, pollutants, and specific electrical consumption.
Negative-ion assistance was likewise examined at one fixed generator condition. The unit operated from a 12 V DC supply, with a rated electrical consumption below 1 W, an internal high-voltage output of approximately − 9.5 kV, and the fixed emitter arrangement described in Sect. 2.6. The current experiments establish the effect of switching this source ON under the specified reactor conditions, but they do not establish optimum voltage, ion-generation intensity, emitter geometry, current density, emitter-to-flow distance, or residence time. These parameters may interact with gas velocity, temperature, humidity, particle concentration, charge attachment, recombination, and wall losses. A dedicated ion-intensity and electrode-configuration study is therefore required.
Spatial representativeness is another limitation. The comparative concentration histories were obtained under the reported sampling configuration and consequently characterize pollutant behavior at those measurement locations rather than a complete three-dimensional concentration field throughout the reactor. Future work should include coordinated measurements at multiple axial and radial positions across the primary combustion chamber, connecting duct, secondary chamber, and exhaust pathway. Such measurements would help distinguish initial pollutant formation from subsequent oxidation, reduction, deposition, dilution, or post-combustion transformation.
The detailed physical mechanism of negative-ion assistance also remains unresolved experimentally. Temperature and flue-gas composition provide direct evidence of the reactor response, whereas ionic wind, electrohydrodynamic momentum transfer, charge-assisted transport, and local flow redistribution remain mechanistic interpretations. Local ion number density, electric-field strength, flame current, charge flux, and ion-induced gas velocity were not spatially measured. Future investigations should therefore incorporate ion-current measurements, electric-field mapping, particle-image velocimetry, high-speed flame visualization, and coupled CFD–electrohydrodynamic analysis to separate aerodynamic and electrical contributions more rigorously.
An equivalent limitation applies to the detailed HHO reaction mechanism. Although the measured combustion response is consistent with established H₂/O₂ chemistry, the present experiments did not directly quantify H, O, OH, HO₂, or related reactive intermediates. Consequently, radical-mediated interpretations should remain mechanistic rather than experimental claims. Optical emission spectroscopy, laser-induced fluorescence, advanced mass spectrometry, or other species-resolved diagnostics combined with validated detailed-chemistry calculations would provide direct evidence of the reaction pathways responsible for the HHO-associated response.
The nitrogen-conversion analysis has also been substantially strengthened by including experimentally measured NO₂ and total NOx. The decrease in NO₂ together with NO demonstrates that the lower NO response cannot be attributed simply to conversion of NO into NO₂, while the reduction of total NOx from 70.0 to 49.3 ppm provides a more complete measure of nitrogen-oxide suppression. Nevertheless, the final partitioning of fuel-bound nitrogen cannot yet be closed quantitatively. In particular, fuel-derived N₂ was not distinguishable from the much larger atmospheric-N₂ background. Therefore, although the simultaneous reductions in HCN, NH₃, NO, NO₂, and total NOx are consistent with increased importance of N₂-forming pathways22,23,24,25, preferential conversion of fuel nitrogen to N₂ has not been directly demonstrated. A future complete nitrogen balance, preferably including isotopically labelled fuel nitrogen where practicable, would allow N₂ selectivity and individual fuel-N conversion pathways to be quantified.
The broader environmental assessment is based on experimental measurements of PM, VOCs, HCl, and PCDD/Fs, rather than semi-empirical formation indices. Their normalized presentation relative to Ion OFF is used only to facilitate comparison among operating modes and should not be confused with model prediction. Future validation should nevertheless increase the number of independently replicated measurements, quantify analytical uncertainty, report absolute concentrations under standardized dry-gas/reference-O₂ conditions where required, and apply relevant regulatory reference methods so that laboratory comparisons can be translated more directly into compliance-oriented emission assessment.
The comparatively small HCl reduction further demonstrates that improved combustion cannot replace dedicated acid-gas treatment. HCl formation and partitioning depend principally on chlorine input, mineral composition, alkali content, gas–solid interactions, and downstream thermal history. Similarly, PCDD/F formation and destruction depend on precursor concentrations, chlorine chemistry, fly-ash surface properties, catalytic metals, oxygen concentration, and residence time in the relevant post-combustion temperature window. Future studies should therefore combine upstream ion/HHO combustion control with detailed characterization of chlorine partitioning, fly ash, cooling-zone thermal history, and downstream flue-gas treatment.
The electrical requirements of both assistance systems are now quantified, reducing one important uncertainty in the engineering assessment. HHO generation required approximately 44–88 W, or 0.044–0.088 kWh per approximately 1 h experiment, while the negative-ion generator required < 1 W, or < 0.001 kWh. The combined auxiliary electrical requirement represented approximately 0.42–0.82% of the nominal 10.83 kWh chemical-energy input of the MSW batch. These values demonstrate that the electrical assistance penalty is modest on a nominal fuel-energy basis under the investigated conditions.
However, this comparison is not equivalent to a complete net-energy or economic analysis. Practical evaluation requires measurement of useful recovered heat or power, combustion efficiency, residual carbon in ash, wall and exhaust heat losses, combustion-air and extraction-fan electricity, downstream pollution-control energy, electrolyzer water consumption, component degradation, and maintenance requirements. A complete techno-economic assessment should additionally include electricity tariff, capital cost of the electrolyzer and ionizer, power electronics, electrolyte and electrode replacement, safety equipment, equipment lifetime, maintenance, throughput, and any economic benefit associated with improved combustion or reduced downstream pollutant burden.
Long-duration durability and scale-up remain particularly important. Laboratory-scale operation does not reproduce all challenges encountered during continuous or semi-continuous MSW incineration. Electrode degradation, electrolyte management, emitter contamination, ash deposition, corrosion, chlorine exposure, particulate fouling, flashback protection, electrical insulation, and long-term reliability may alter both performance and operating cost. Feedstock variability in moisture, ash, plastics, chlorine, nitrogen, sulfur, and particle size may also change the relative response to ion and HHO assistance.
Accordingly, the next stage should consist of a structured multi-factor experimental program in which excess-air ratio, HHO dosage, and ion-source intensity are varied independently and interactively, followed by pilot-scale validation with representative heterogeneous MSW. Such a program should combine combustion and emission measurements with complete electrical and thermal energy accounting, repeatability and uncertainty analysis, spatial ion/radical diagnostics, durability testing, and techno-economic assessment. This approach would establish response surfaces, interaction effects, optimum operating windows, scale-up criteria, and practical feasibility without extrapolating the present laboratory results beyond the conditions directly demonstrated.