Background and related work
Sparse-view computed tomography (CT) reconstruction aims at producing diagnostically relevant images from limited projection data, with the twin objectives of minimizing radiation dose and scan time. Classical iterative reconstruction methods, like the Simultaneous Algebraic Reconstruction Technique (SART)28, tend to include regularization terms to restrict the solution space and suppress noise and artifacts. To address these shortcomings, various extensions have been proposed, including improved TV models for few-view reconstruction29 and group-sparsity regularization that enforces structural correlations among image pixels30. TV regularization, which is effective in noise reduction but can result in over-smoothing and loss of fine structural details. Relative Total Variation (RTV)31 was developed, which provided adaptive smoothing by involving image gradient information and spatial context. This approach enables edge-aware regularization that adheres to anatomical boundaries through spatially adaptive gradient weighting.
Recently, He et al.32 proposed Bilateral Weighted Relative Total Variation (BRTV) for low-dose CT reconstruction, demonstrating improved edge preservation compared with conventional RTV. However, their method relies on globally fixed regularization parameters and does not incorporate anatomy-guided spatial adaptation. In contrast, the proposed framework introduces spatially varying regularization weights derived from tissue segmentation masks, enabling tissue-specific adaptive regularization within the RTV framework. The resulting segmentation masks are subsequently converted into tissue-specific α-maps that spatially modulate the SvRTV regularization.
Deep learning approaches, in particular encoder-decoder networks like U-Net33, have attracted considerable interest in the last few years for image reconstruction and segmentation as well as image denoising34. Such architectures are inherently suited to capturing intricate spatial patterns and have shown impressive performance in medical imaging tasks. Proposed U-Net learning frameworks boost efficiency and generalizability by permitting the network to learn related tasks in parallel35. Further, the addition of parameter prediction branches in such networks has facilitated adaptive regularization. With the ability to dynamically predict model parameters, such networks can accommodate variations in tissue properties, noise characteristics, and acquisition protocols36. To balance multiple loss functions during training, techniques such as task uncertainty weighting and gradient normalization have been investigated37,38, resulting in more stable convergence and fairer learning across tasks. More recently, analytical approaches to uncertainty-based loss weighting have been proposed for multi-task learning scenarios39.
Systematic comparison with closely related works
To clearly position our contribution, Table 1 provides a systematic comparison of our method with six representative closely related approaches across five key features: (1) spatially varying parameter prediction, (2) joint reconstruction‑segmentation, (3) RTV/BRTV‑based regularization, (4) end‑to‑end learning, and (5) uncertainty/confidence map output. As shown, our method is the only one that simultaneously possesses all five characteristics.
Table 1 Systematic comparison of the proposed method with related works.
Table 1. Feature comparison between the proposed SvRTV-UNet and representative sparse-view CT reconstruction methods. Spatially varying regularization parameters denote image-dependent adaptive regularization (e.g., λ and/or α maps) rather than globally optimized hyperparameters.
Additionally, recent advances have further expanded the field with sophisticated generative models. These include U-Net-based deep convolutional framelet (DCF) models24 and score-based generative frameworks with conditional null-space learning for limited-angle tomography43. Chen et al.26 revisited the RED-CNN architecture for low-dose CT, confirming its effectiveness as a strong baseline for deep learning-based denoising. Our method differs from these by preserving a strong physics‑based regularization core, which inherently avoids hallucination and ensures data consistency, a known limitation of purely generative approaches.
MethodologyDataset description
We conducted our experiments on the Lung CT Screening dataset from The Cancer Imaging Archive (TCIA), specifically the LIDC-IDRI collection44. Our study cohort comprised a randomly selected subset of 50 subjects from this database.
Critical Note on Data Splitting: To rigorously prevent data leakage, a critical pitfall in medical image analysis where highly correlated slices from the same patient can contaminate both training and evaluation sets the dataset was partitioned strictly at the patient level before any slice extraction. Specifically, the 50 patients were randomly divided into three non-overlapping groups: 40 patients for training, 5 patients for validation, and 5 patients for independent testing. Consequently, all axial slices sourced from a single patient are guaranteed to reside exclusively within one subset, ensuring zero anatomical overlap between the training, validation, and test sets.
From these pre-partitioned patient groups, we randomly sampled approximately 1000 axial slices in total (roughly 20 slices per patient), maintaining a balanced distribution across the training (approx. 800 slices), validation (approx. 100 slices), and test (approx. 100 slices) sets. Slices located entirely above the lung apices or below the diaphragm were systematically excluded, as they lack the anatomical structures relevant to the joint reconstruction and segmentation task. The slice thickness ranges from 1.25 to 3.0 mm. The scan protocol was as follows: tube voltage 120 kVp, tube current 200 mAs, and reconstruction kernel standard. The Hounsfield unit range was −1000 to + 1000. Crucially, the LIDC-IDRI dataset does not inherently contain pixel-level segmentation masks for the lung and chest wall. Therefore, the ground-truth anatomical masks (lung and chest regions) required for our joint reconstruction–segmentation task were manually delineated for all selected slices by an experienced board-certified radiologist. This annotation process ensured high-quality, clinically reliable labels for training and evaluation.
Although the original CT volumes are inherently 3D, our model was trained on 2D axial slices independently. To standardize input dimensions, all images were resized to 256 × 256 pixels for the reconstruction grid. The U-Net, however, operates at a reduced input resolution of 128 × 128 pixels. Before being fed to the network, the SART reconstruction is downsampled from 256 × 256 to 128 × 128 via bicubic interpolation. The network predicts segmentation masks and scalar parameters at this resolution. The predicted masks are then upsampled back to 256 × 256 using nearest-neighbor interpolation to construct the alpha map at the native reconstruction resolution. This two-resolution strategy keeps the network compact without sacrificing final image quality, since the parameter prediction heads employ global average pooling and are inherently resolution-agnostic. The Dual-Decoder U-Net with 64 base filters and an encoder depth of 5 utilizes approximately 80 million parameters. Preliminary experiments indicated that parameter prediction accuracy at 128 × 128 differs by less than 1.5% from predictions at 256 × 256. This acknowledged limitation is further discussed in Section “Limitations”.
The framework employs a two-resolution strategy: The U-Net operates on 128 × 128 inputs, while the reconstruction is performed at the native resolution of 256 × 256 pixels. The reconstruction itself is done at 256 × 256 pixels—that is where the final image quality matters, and that is where all our quantitative metrics are computed. The U-Net, on the other hand, takes a 128 × 128 input. The reason is straightforward: the network’s main job in this framework is not to produce the final image, but to predict a handful of scalar parameters λ, A1, and A2 along with coarse segmentation masks that distinguish chest wall from lung tissue. These are global or region-level quantities. They do not depend on fine spatial detail in the way that, say, detecting a small nodule would. Global average pooling sits right before the parameter prediction heads, so feeding the network a larger image would produce the same pooled feature vector just computed over a finer grid. We tested this empirically, and the difference in the predicted λ and tissue parameters between 128 × 128 and 256 × 256 was under two percent, while the segmentation Dice scores remained essentially unchanged. Meanwhile, keeping the network at 128 × 128 makes training faster and reduces GPU memory use, which is a practical concern when the network is called repeatedly inside an iterative reconstruction loop. So the two-resolution design is not a compromise we had to make—it follows naturally from the fact that the primary contribution of this work is the reconstruction framework, and the U-Net serves as an efficient parameter estimator within that framework.
The input to the network consists of three channels derived from the original CT image I, providing complementary tissue-specific contrast information: Channel 1 (Original): I1 = I , Channel 2 (Soft Tissue Window): I2 = clip((I–0.25) / 0.4, 0, 1), Channel 3 (Lung Window): I3 = clip((I–0.02) / 0.23, 0, 1) These three windows emphasize different anatomical structures: the original image preserves global contrast, the soft-tissue window highlights the chest wall and mediastinum, and the lung window enhances air-filled regions and pulmonary vasculature.
Standard preprocessing techniques were employed to promote model robustness and generalizability. Image Normalization: Each channel of the multi-channel input was independently normalized using min–max scaling to the range \([\text{0,1}]\). For each channel c, \(the transformation\)\({I}_{c}^{norm }=({I}_{c}-{I}_{c}^{min }/\left({I}_{c}^{max }-{I}_{c}^{min}\right)\) was applied, where \({I}_{c}^{min}\) and \({I}_{c}^{max}\) are the minimum and maximum pixel values of channel \(c\) across the training set. This per-channel normalization preserves the relative contrast within each tissue-specific window while ensuring all channels contribute equally to the network input.
Parameter Normalization: The regularization parameter λ was normalized using log-space standardization with robust statistics to handle its exponential dynamic range ( \({10}^{-6}\) to \({10}^{-3}\) ). Specifically, \({\lambda}_{norm }=(\text{l}\text{o}\text{g}\lambda -\) median \((\text{l}\text{o}\text{g}\lambda ))/\text{S}\text{T}\text{D}(\text{l}\text{o}\text{g}\lambda \)), where mean and std are computed from the training data It is worth emphasizing that the ground-truth λ values we use for training come from the NPS-based noise characteristics of the reconstructed image (Section “Evaluation and preprocessing strategy“), not from the projection view count. This means the network learns to map image quality features—noise texture, artifact patterns, and edge sharpness—to the appropriate regularization strength, rather than simply memorizing a fixed λ for each view count (e.g., ’64 views means λ = 0.00001′). The practical upside is that at inference time, the network can predict a sensible λ for any input image no matter how many views were used to reconstruct it. The tissue parameters \({A}_{1}\) and \({A}_{2}\) were normalized using percentile-based min–max scaling: \({A}_{k}^{norm }=\left({A}_{k}-{P}_{5}\left({A}_{k}\right)\right)/\left({P}_{95}\left({A}_{k}\right)-{P}_{5}\left({A}_{k}\right)\right)\), where \({P}_{5}\) and \({P}_{95}\) denote the 5th and 95th percentiles, respectively. This approach clips extreme outliers while mapping the central \(90\text{\%}\) of the distribution to \([\text{0,1}]\), ensuring stable network training.
Online data augmentation was applied during training, consisting of random in-plane rotations (± 10°), random horizontal and vertical translations (± 10 pixels), and random horizontal and vertical reflections (Random X/Y Reflection with 100% probability).
To simulate sparse-view acquisitions, projection data were generated using a fan-beam geometry with a progressively sparse number of views: 32, 50, 64, 96, and 128. The forward model, which approximates the Radon transform of the grayscale CT images, produces sinograms that serve as the input to our reconstruction algorithm. Our proposed reconstruction pipeline proceeds in the following sequential steps:
-
Initial Reconstruction An initial estimate of the CT image is computed by applying the Simultaneous Algebraic Reconstruction Technique (SART) on the sparse sinogram data for a predetermined number of iterations.
-
Segmentation and Parameter Estimation This initial reconstruction is fed into the proposed U-Net, which simultaneously predicts the lung and chest segmentation masks and estimates three key parameters: λ (the SvRTV regularization strength), A₁ (the alpha weight for the chest region), and A₂ (the alpha weight for the lung region).
-
Alpha Map Construction The predicted segmentation masks are combined with the tissue-specific parameters (A₁, A₂) to construct a spatially varying alpha map α(n), as defined in Eq. (3).
-
SvRTV Regularization The final reconstructed image is obtained by solving the SvRTV -regularized objective function (Eq. 8). This step performs iterative edge-preserving smoothing, guided by the anatomy-aware alpha map, which adaptively adjusts the regularization strength across different tissue types.
-
Quality Assessment The performance of the reconstruction is assessed quantitatively using Peak Signal-to-Noise Ratio (PSNR), Structural Similarity Index Measure (SSIM), Mean Squared Error (MSE), Root Mean Squared Error (RMSE), and Noise Power Spectrum (NPS) analysis to provide complementary evaluation of image quality.
-
The SvRTV regularization itself is formulated with spatial Gaussian kernels, modulated by the predicted alpha map to direct region-adaptive smoothing that preserves critical anatomical boundaries.
CT Imaging model
The forward model for X-ray computed tomography (CT) acquisition can be represented as a discrete linear system as, Af = b45, where f = [f1, f2, f3, …, \({\text{f}}_{\text{N}}\)]T ∈ ℝM is the vectorized unknown image, with each element representing the linear attenuation coefficient of a pixel in the object, b = [b1, b2, b3, …, \({\text{b}}_{\text{M}}\) ]T ∈ ℝM is the measured projection data (sinogram). The system matrix A ∈ ℝM×N models the forward projection process, with each element aij representing the contribution of pixel j to the line integral measured at detector bin i. This matrix is typically constructed using Siddon’s ray-driven algorithm46. Reconstructing f from undersampled measurements b (where M < < N) is a fundamentally ill-posed inverse problem. The system has infinitely many solutions that satisfy the underdetermined equation Af ≈ b, meaning prior knowledge must be incorporated to find a physically meaningful and stable solution. This is achieved by formulating the reconstruction as a regularized optimization problem:
$$\underset{f}{\arg\min} \left\{ \|Af-b\|_2^2 + \lambda R(f) \right\}$$
(1)
This objective function consists of two key terms: the data fidelity term \({\Vert \text{A}\text{f}-\text{b}\Vert }_{2}^{2}\), which ensures the solution remains consistent with the acquired measurement data b; and the regularization term R(f), which incorporates prior knowledge about the expected properties of the image (e.g., piecewise smoothness). The regularization parameter λ > 0 controls the trade-off between data consistency and the enforcement of these prior assumptions. The choice of the regularizer R(f) is critical. This work introduces a novel, anatomically guided regularizer, the Spatially varying Relative Total Variation (SvRTV), designed to overcome these limitations.
Spatially varying relative total variation (SvRTV)Intuitive step‑by‑step explanation of SvRTV
Before presenting the mathematical formulation, we provide an intuitive explanation. The SvRTV regularizer operates in four conceptual steps:
-
Step 1: Spatial Weight Computation: For each pixel, we compute spatial weights where nearby pixels contribute more to the regularization. A Gaussian pre-filter is applied to the image to reduce noise sensitivity before computing gradient-based weights.
-
Step 2: Gradient Weight Construction: Using the spatially weighted gradients in both x and y directions, the regularization becomes edge-preserving because pixels across strong edges receive lower weights.
-
Step 3: Alpha Map Modulation: The segmentation masks (chest vs. lung) and the predicted tissue weights (A₁, A₂) are combined to create a spatially varying alpha map α(n). Regions with higher predicted noise (e.g., lung) receive stronger regularization, while regions with fine details (e.g., vessels) receive weaker regularization.
-
Step 4: Iterative Update: The final reconstructed image is obtained by solving a linear system that balances the data fidelity term (how well the image matches measurements) with the SvRTV term (how smooth the image is, modulated by α). This is solved iteratively using Eq. (8).
Figure 1 schematically illustrates this four-step workflow. The U-Net first predicts the segmentation masks (chest and lung) along with the tissue-specific weights A₁ and A₂. These outputs are then combined via Eq. (3) to construct the spatially varying alpha map α(n), which subsequently modulates the gradient weights in the SvRTV regularizer. The regularized image is obtained by solving the linear system in Eq. (8), and the process repeats iteratively until convergence.
Fig. 1
visually depicts this workflow, showing how α(n) is constructed from A₁ and A₂ and then guides the iterative reconstruction.
Our SvRTV formulation builds upon and extends the RTV framework31,47 by introducing a spatially varying weight map α(n) that modulates the regularization strength according to the anatomical region. The underlying gradient-based weight computation remains consistent with the RTV mathematical structure, with the key innovation being the anatomy-guided spatial adaptation learned from segmentation masks.
To solve the gradient problem by removing small structures and preserving image edges, we will need different penalty weights. For this purpose, RTV31,47 is defined based on the difference in the partial derivatives obtained by the image structures. RTV was first proposed to extract image structures from its textures, but in47,48, this method was also used for some imaging models in CT scans, in which case, the noise will also leave its effect on partial derivatives. Of course, in this paper, the image artifacts caused by the limited views will also affect the partial derivatives obtained; however, these artifacts will be mitigated during the execution of the algorithm, as will be explained later. Only image structures will remain.
Following the derivation approach of32,42, the SvRTV minimization problem can be expressed as an iterative two-step procedure. Initially, the data fidelity term is solved by the SART, and an interim image is calculated that we denote \({f}^{k+\raisebox{1ex}{$1$}\!\left/ \!\raisebox{-1ex}{$2$}\right.}=SART\left({f}^{k}\right)\). Next is the solving of the SvRTV minimization problem, which is formulated as a regularized denoising step applied to the interim image:
$$\underset{f \geq 0}{\arg\min} \sum_{m}\left[{\left({f}_{m}-{f}_{m}^{\left(k+1/2\right)}\right)}^{2}+\lambda \cdot SvbRTV\left({f}_{m},\widetilde{{f}_{m}}\right)\right]$$
(2)
The first term \({\left({f}_{m}-{f}_{m}^{\left(k+\raisebox{1ex}{$1$}\!\left/ \!\raisebox{-1ex}{$2$}\right.\right)}\right)}^{2}\) ensures the solution remains close to the SART interim image (data consistency), while the SvRTV term provides edge-preserving, anatomy-guided regularization. The parameter λ controls the balance between these two terms.
The complete step-by-step procedure of the proposed SvRTV-based U-Net minimization algorithm is summarized in Table 2.
Table 2 Steps of the SvRTV -based U-Net minimization algorithm.
To improve the quality of few-view CT image reconstruction, we introduce a spatially variant RTV regularization that varies the regularization strength across anatomical regions according to region quality. Through segmentation of the input image and the use of the predictions A₁ and A₂, a weighting map is proposed that scales and tunes up the regularization term. In CT images, the chest and lungs exhibit different noise levels and structural complexities and therefore require region-dependent regularization. The quality scalars A₁ and A₂ for each region represent the noise and artifact levels and allow the regularization to place greater weight on noise-prone areas (higher A1 or A2) while preserving details in high-quality regions (lower A1 or A2). Such an SvRTV regularization technique allows anatomically informed regularization and enhances reconstruction quality by balancing noise reduction and detail preservation across varied region-wise areas.
The spatially varying alpha map is constructed using indicator functions:
$$\begin{aligned}\alpha(n)&=A_{1}\cdot 1_{\mathrm{chest}}(n)+A_{2}\cdot 1_{\mathrm{lung}}(n)+1\cdot 1_{\mathrm{background}}(n),\;\\&\text{where}:\\&\!\!\!\!\!\!\!\!\!\!1_{\mathrm{chest}}(n)=\begin{cases}1,&\text{if }n\in\Omega_{\mathrm{chest}}\\0,&\text{otherwise}\end{cases},\\&\!\!\!\!\!\!\!\!\!\!1_{\mathrm{lung}}(n)=\begin{cases}1,&\text{if }n\in\Omega_{\mathrm{lung}}\\0,&\text{otherwise}\end{cases},\\&\!\!\!\!\!\!\!\!\!\!1_{\mathrm{background}}(n)=\begin{cases}1,&\text{if }n\notin\Omega_{\mathrm{chest}}\cup\Omega_{\mathrm{lung}}\\0,&\text{otherwise}\end{cases},\\&\text{with the constraint}:\\&\!\!\!\!\!\!\!\!\!\!1_{\mathrm{chest}}(n)+1_{\mathrm{lung}}(n)+1_{\mathrm{background}}(n)=1,\;\forall n.\end{aligned}$$
(3)
Define the spatial weight \({h}_{m,n}\) as:
$${h}_{m,n}=exp\left(-\frac{{\left({i}_{m}-{i}_{n}\right)}^{2}+{\left({j}_{m}-{j}_{n}\right)}^{2}}{2{\sigma}_{s}^{2}}\right) $$
(4)
Now we will solve the problem for both the x and y directions. First, we will have for the x direction:
$$ \begin{gathered} \sum\limits_{m} {\frac{{\left( {D_{x} f_{m} } \right)}}{{L_{x} \tilde{f}_{m} + \varepsilon }}} = \sum\limits_{n } {\alpha \left( n \right)} \cdot \mathop \sum \limits_{m \in R\left( n \right)} \frac{{\left( {h_{m,n} } \right)}}{{\left| {\mathop \sum \nolimits_{n \in R\left( m \right)} h_{m,n} \cdot \partial_{x} \tilde{f}_{n} } \right| + \varepsilon }}\left| {\partial_{x} f_{n} } \right| \hfill \\ \approx \mathop \sum \limits_{n} \alpha \left( n \right) \cdot \mathop \sum \limits_{m \in R\left( q \right)} \frac{{h_{m,n} }}{{L_{x} \tilde{f}_{m} + \varepsilon }}{ }\frac{1}{{\left| {\partial_{x} f_{n} } \right| + \zeta }}\left( {\partial_{x} f_{n} } \right)^{2} = \mathop \sum \limits_{n} u_{x,n} w_{x,n} \left( {\partial_{x} f_{n} } \right)^{2} \hfill \\ \end{gathered} $$
(5)
where ε and ζ are small constants to prevent division by zero. We will continue:
$${u}_{x,n}={\left({G}_{\sigma }*\frac{1}{\left|{G}_{\sigma }*{\partial}_{x}{\widetilde{f}}\right|+\varepsilon }\right)}_{n} , {w}_{x,n}=\alpha \left(n\right)\cdot \frac{1}{\left|{\partial}_{x}{f}_{n}\right|+\zeta }$$
(6)
\({G}_{\sigma }\) is a Gaussian filter, and * is a convolution operator. For the y-direction, we will have a similar process to the x-direction. Equations (5) and (6) can be rewritten in matrix–vector form, leading to the following SvRTV minimization problem:
$$\underset{f \geq 0}{\arg\min} \left[ {\left({{\varvec{v}}}_{f}-{{\varvec{v}}}_{{f}^{k+\frac{1}{2}}}\right)}^{T}{\left({{\varvec{v}}}_{f}-{{\varvec{v}}}_{{f}^{k+\frac{1}{2}}}\right)}+\lambda \cdot \left({{\varvec{v}}}_{f}^{T}{{\varvec{C}}}_{x}^{T}{{\varvec{U}}}_{x}{{\varvec{W}}}_{x}{{\varvec{C}}}_{x}{{\varvec{v}}}_{f}+{{\varvec{v}}}_{f}^{T}{{\varvec{C}}}_{y}^{T}{{\varvec{U}}}_{y}{{\varvec{W}}}_{y}{{\varvec{C}}}_{y}{{\varvec{v}}}_{f}\right) \right]$$
(7)
In the above equation, \({v}_{f},{v}_{{f}^{k+\raisebox{1ex}{$1$}\!\left/ \!\raisebox{-1ex}{$2$}\right.}}\) are vector forms of \(f,{f}^{k+\raisebox{1ex}{$1$}\!\left/ \!\raisebox{-1ex}{$2$}\right.}\) images, \({C}_{x}\) and \({C}_{y}\) are Toeplitz matrices from the discrete gradient operator with forward difference. Also, \({U}_{x}{,W}_{x}\) and \({U}_{y}{,W}_{y}\) are diagonal matrices with diagonal elements \({w}_{x,n},{u}_{x,n}\) and \({w}_{y,n},{u}_{y,n}\) respectively. Solving a linear system iteratively can yield the correct solution. For example, the k-th iteration is as follows, with αα included as a diagonal matrix:
The iterative update with α as a diagonal matrix:
$$\left(\mathbf{1}+{\lambda}_{a }{\alpha {\varvec{S}}}^{t}\right)\cdot {{\varvec{v}}}_{f}^{t+1}={{\varvec{v}}}_{{f}^{SART}}$$
(8)
where 1 is the identity matrix, α = diag (\({\alpha}_{1}\), \({\alpha}_{2}\), …, \({\alpha}_{n}\)) is a diagonal matrix containing the spatially varying alpha map values, and \({{\varvec{S}}}^{t}={{\varvec{C}}}_{x}^{T}{{\varvec{U}}}_{x}^{t}{{\varvec{W}}}_{x}^{t}{{\varvec{C}}}_{x}+{{\varvec{C}}}_{y}^{T}{{\varvec{U}}}_{x}^{t}{{\varvec{W}}}_{x}^{t}{{\varvec{C}}}_{y}\).
Also, \(\left(\mathbf{1}+\lambda \alpha {{\varvec{S}}}^{t}\right)\) is a symmetric positive definite Laplacian.
Table 3 is a comprehensive notation that defines all mathematical symbols, variables, and operators used in the SvRTV formulation and reconstruction algorithm.
Table 3 Notation table for key variables.Resolution-aware dynamic lambda scaling
The U-Net predicts a base regularization parameter, \({\lambda}_{pred}\), from an input downsampled to 128 × 128, while the SvRTV regularizer in Eq. (8) operates at the native reconstruction resolution of 256 × 256. This resolution mismatch introduces two effects that a static λ cannot address: the digital scale of anatomical structures changes with pixel dimensions, and the intermediate reconstruction quality should modulate the need for regularization.
To handle these, we modulate the network-predicted base lambda using a principle-driven correction formula. The adaptive lambda used in Eq. (8) is: \({\lambda}_{a}={\lambda}_{pred }\cdot\Lambda (\text{P}\text{S}\text{N}\text{R})\cdot {s}^{\gamma }\). Each term addresses a specific physical or data-driven factor:
-
\(\Lambda (\text{P}\text{S}\text{N}\text{R})\): Reduces regularization strength as the intermediate SART reconstruction quality improves. This follows the established inverse relationship between data fidelity and prior enforcement, a principle central to adaptive methods such as Nonlinear Neighborhood Filters49.
-
\({s}^{\gamma }\): Corrects for the change in the digital scale of anatomical structures caused by the altered pixel dimensions between the two resolutions ( \(s={R}_{r}/{R}_{n}=2,\gamma =0.15\) ).
The quality modulation function Λ(PSNR) is defined as a step-wise decreasing function of the PSNR of the intermediate reconstruction, with a conservative schedule during early iterations to allow the reconstruction to stabilize before aggressive regularization is applied.
This dynamic, resolution-aware scaling moves beyond the static λ of conventional RTV methods32,42. It translates a λ estimated at a coarser resolution into an effective regularization strength at the native resolution.
Network architecture and training
The centerpiece of our framework is a Dual-Decoder U-Net architecture designed for multi-task learning with five simultaneous outputs. The network accepts a 128 × 128 × 3 multi-channel CT image as input. It produces a chest segmentation mask, a lung segmentation mask, and three scalar parameters (λ, A₁, A₂) through a shared encoder with two separate decoder branches.
-
Shared Encoder: The encoder consists of 5 levels, each containing two consecutive 3 × 3 convolutional layers with batch normalization and ReLU activation, followed by a 2 × 2 max pooling layer with stride 2 for downsampling. The base number of filters is 64, doubling at each subsequent level: 64 → 128 → 256 → 512 → 1024, with 2048 filters at the bottleneck. This shared encoder extracts hierarchical features common to both anatomical structures.
-
Bottleneck: The bottleneck comprises two 3 × 3 convolutional layers with 2048 filters each, batch normalization, ReLU activation, and a dropout layer with rate 0.2 for regularization. The bottleneck representation is shared between both decoder branches.
-
Dual Decoders: Two separate decoder branches—Chest Decoder and Lung Decoder—each mirror the encoder structure with 5 levels. Each decoder level begins with a 2 × 2 transposed convolution for upsampling, followed by concatenation with the corresponding encoder feature map via skip connections (preserving spatial information), and two subsequent 3 × 3 convolutional layers with batch normalization and ReLU activation. This dual-decoder design enables each anatomical structure (chest wall and lungs) to be processed through its own specialized feature pathway, allowing the network to learn structure-specific representations.
-
Output Heads: Each decoder terminates with a 1 × 1 convolution with sigmoid activation, producing the chest and lung segmentation masks, respectively. For parameter prediction, the final feature maps from both decoders are concatenated and passed through a global average pooling layer, followed by shared fully-connected layers of 512 and 256 units with ReLU activation and dropout regularization (rate = 0.3). From this shared representation, three separate branches predict the scalar parameters: λ (regularization strength), A₁ (chest tissue weight), and A₂ (lung tissue weight).
Figure 2 illustrates the complete architecture, emphasizing the shared backbone and the four separate output streams. The U-Net operates on 128 × 128 inputs for computational efficiency, while the final SvRTV-regularized reconstruction is performed at the native 256 × 256 resolution. The segmentation masks are upsampled from 128 × 128 to 256 × 256 before constructing the alpha map. A detailed summary of all architectural hyperparameters is provided in Table 4.
Fig. 2
Proposed dual-decoder U-Net architecture. The network consists of a shared encoder, a bottleneck, and two task-specific decoder branches for simultaneous chest and lung segmentation. The shared encoder extracts hierarchical feature representations using successive convolutional blocks and max-pooling operations, while the bottleneck captures high-level semantic information. The decoder branches progressively recover spatial resolution through transposed convolutions and integrate multi-scale features from the encoder via skip connections to generate accurate segmentation masks. In parallel, the bottleneck features are processed by a Global Average Pooling (GAP) layer followed by fully connected layers for the prediction of the auxiliary parameters λ, A₁, and A₂.
Table 4 Hyperparameters of the proposed U‑Net architecture.Evaluation and preprocessing strategy
We utilized a rigorous and standardized preprocessing pipeline to ensure data reliability, model generalizability, and imposition of clinically relevant priors on the training data. All input Computed Tomography (CT) images and Anatomical Masks used in network training were collected by a radiologist.
The complete workflow of the proposed method, from initial SART reconstruction through U-Net-based parameter prediction to final SvRTV refinement, is illustrated in Fig. 3.
Fig. 3
A visual representation of the workflow in a flowchart format.
Regularization Parameter (λ): The reference value \(\hat{\lambda }\) is estimated for each image using the Noise Power Spectrum (NPS). This approach is fundamentally different from tying λ to a view count, as the NPS-based metric captures the true image quality, which depends on patient anatomy, tissue composition, and acquisition parameters—not solely on the number of projections. The resulting noise metric η ∈ [0,1] is mapped to the clinically relevant range [10−6, 10⁻3] through a log-space transformation: \(\hat{\lambda }=\text{e}\text{x}\text{p}\left(\text{l}\text{o}\text{g}{L}_{1}+\eta \cdot \text{l}\text{o}\text{g}\left({L}_{2}/{L}_{1}\right)\right)\), where L1 = 10−6 and L2 = 10⁻3. A small random perturbation (± 15% in log-space) is added to prevent the network from simply memorizing fixed values.
This quality-driven approach enables a single trained network to operate across multiple view-count scenarios without requiring separate models for each acquisition protocol. At inference, the network automatically predicts a higher λ for noisier reconstructions (e.g., 50 views) and a lower λ for cleaner ones (e.g., 96 views) based solely on image appearance, without explicit knowledge of the view count. For training, \(\hat{\lambda }\) is normalized using log-space standardization: \({\lambda}_{train }=\left(\text{l}\text{o}\text{g}\hat{\lambda }-{\mu}_{\text{l}\text{o}\text{g}}\right)/{\sigma}_{\text{l}\text{o}\text{g}}\) where \({\mu}_{\text{l}\text{o}\text{g}}\) and \({\sigma}_{\text{l}\text{o}\text{g}}\) are the median and median absolute deviation (MAD) of the log-transformed training values. A controlled Gaussian perturbation (σ = 0.1 in log-space) is introduced during dataset preparation to augment the data and promote generalization. This preprocessing is performed once and does not affect training or inference time. The resulting \(\hat{\lambda }\)serves as the regression target for the Huber loss \({L}_{\uplambda }\) (Section “Proposed U-net loss function“).
Derivation of Tissue-Specific Quality Parameters (A1, A2): The tissue-specific parameters A₁ (chest) and A₂ (lung) serve a dual role in our framework. Their physiological interpretation is anchored in Hounsfield Unit (HU) statistics—A₁ is normalized to a soft-tissue reference of approximately 40 HU (representing muscle and parenchyma), while A₂ is normalized relative to the air reference (–1000 HU), constituting a relative density index for lung parenchyma. The initial ground-truth targets are generated from the median HU values within the corresponding tissue regions: A₁ is derived via \({A}_{1}=0.86+0.06\cdot {I}_{chest }^{median }+\epsilon \) and mapped to the physiological range [0.85, 0.92], while A₂ is similarly derived via \({A}_{2}=0.73+0.03\cdot {I}_{lung }^{median }+\epsilon \) within [0.72, 0.76], where \(\epsilon \sim \text{N}\left(0,{0.01}^{2}\right).\) An anatomical constraint \({A}_{1}>1.10\cdot {A}_{2}\) is enforced to reflect the higher attenuation of chest tissue relative to lung parenchyma. During training, the regression targets are refined through a self-supervised procedure (Section “Ground‑truth target generation for A₁ and A₂ (self‑supervised procedure)“) that dynamically combines segmentation accuracy (Dice), intensity fidelity (PSNR), and edge sharpness metrics. This hybrid approach ensures that A₁ and A₂ reflect both anatomical reality and perceptual reconstruction quality, with the network consistently converging to physiologically meaningful values (A₁ ≈ 0.88, A₂ ≈ 0.74; Table 7).
For network training, both \({A}_{1}\) and \({A}_{2}\) are normalized to \([\text{0,1}]\) using percentile-based min–max scaling: \({A}_{k}^{norm }=\left({A}_{k}-{P}_{5}\left({A}_{k}\right)\right)/\left({P}_{95}\left({A}_{k}\right)-{P}_{5}\left({A}_{k}\right)\right)\). The network predicts normalized values through linear activation, and predictions are denormalized for evaluation: \({A}_{k}={A}_{k}^{norm }\cdot \left({P}_{95}-\right.\left.{P}_{5}\right)+{P}_{5}\).
Ground‑truth target generation for A₁ and A₂ (self‑supervised procedure)
The ground-truth targets for A1 and A2 are computed on-the-fly during training using the following procedure. In each training iteration, the network first performs a single forward pass to generate segmentation predictions and parameter estimates. The self-supervised targets are then computed from these predictions before any gradient update is applied, ensuring that the target generation and weight optimization steps remain strictly sequential with no circular dependency. The U-Net weights remain fixed throughout the target computation step.
-
Step 1: Segmentation Assessment: Compute the Dice similarity coefficient between the predicted segmentation and the ground-truth mask. Higher Dice indicates better anatomical alignment.
-
Step 2: Intensity Restoration Quality: Compute PSNR within the correctly predicted chest and lung regions (pixels where the predicted mask and ground-truth mask intersect). This measures how well the reconstruction preserves true tissue intensities.
-
Step 3: Edge Sharpness Metric: Compute the average Sobel gradient magnitude along the predicted organ boundaries, as defined in50. Higher values indicate sharper, more clinically useful edges.
-
Step 4: Composite Score: A composite quality score is computed for each tissue region as: 0.5 × Dice + 0.3 × (PSNR/50) + 0.2 × (E/100), where E is the mean Sobel gradient magnitude within the predicted mask. The score is computed per image, averaged across the batch, and clipped to [0, 1] before being assigned as the dynamic regression target for A₁ and A₂. The blending factor α = min((epoch − 1) / (Epochs − 1), 1) in the loss function ensures a smooth transition from these self-supervised targets to the network’s own predictions as training stabilizes.
This self-supervised procedure ensures that A₁ and A₂ dynamically reflect the current reconstruction quality throughout training, directly guiding the SvRTV regularizer to emphasize regions where segmentation is confident, intensities are accurate, and edges are sharp.
Proposed U-net loss function
The total loss function combines four tasks through homoscedastic uncertainty weighting25, where all task weights are learned automatically through backpropagation, eliminating the need for manual loss balancing. Let \({s}_{i}=\text{l}\text{o}\text{g}{\sigma}_{i}\) denote learnable uncertainty parameters for each task. The total loss is then given by \({\text{L}}_{total }=\sum_{i\in \left\{\text{s}\text{e}\text{g},\lambda ,{A}_{1},{A}_{2}\right\}} \left[\text{e}\text{x}\text{p}\left(-{s}_{i}\right)\cdot {\text{L}}_{i}+\frac{1}{2}{s}_{i}\right]\), where the parameters are initialized as \({s}_{seg }=0 ,{s}_{\lambda }=0 ,{s}_{{A}_{1}}=0 ,{s}_{{A}_{2}}=0\) and updated via the Adam optimizer alongside all network parameters. The effective weight for task \(i\) is \({w}_{i}=\text{e}\text{x}\text{p}\left(-{s}_{i}\right)=1/{\sigma}_{i}^{2}\), with the regularizer \(\frac{1}{2}{s}_{i}\) preventing weights from collapsing to zero. This formulation requires zero manual loss weight tuning; the network autonomously learns which tasks require more emphasis based on their relative uncertainties.
Two-Phase Progressive Training. To ensure stable convergence, a two-phase training strategy is employed. Let \(t\) denote the current epoch and \({E}_{seg }=50\) be the number of segmentation-only epochs. The loss function at epoch \(t\) is defined as:
$${L}^{(t)}=\left\{\begin{array}{lll}{\text{L}}_{seg },& if \text{t}\le {\text{E}}_{seg }& (Phase 1: Segmentation Only) \\ {\text{L}}_{total },& if \text{t}>{\text{E}}_{seg }& (Phase 2: All Tasks)\end{array}\right.$$
In Phase 1, only the segmentation loss is active, allowing the network to establish reliable anatomical boundaries before introducing parameter prediction tasks. In Phase 2, all four task losses are combined using the learned uncertainty weights from Eq. (1).
-
1.
Segmentation loss
The segmentation loss combines Dice loss and binary cross-entropy (BCE) without manual weighting coefficients. Let \({\hat{y}}_{p}^{k}\in [\text{0,1}]\) denote the predicted probability at pixel \(p\) for class \(k\in \{\) chest, lung \(\}\), and let \({y}_{p}^{k}\in \{\text{0,1}\}\) be the corresponding ground-truth label. The segmentation loss is defined as:
$$\begin{aligned}L_{\text{seg}} &= \underbrace{\left(1-\frac{\text{Dice}_{\text{chest}} + \text{Dice}_{\text{lung}}}{2}\right)}_{\text{Dice Loss}} + \underbrace{L_{\text{BCE}}^{\text{avg}}}_{\text{Binary Cross-Entropy}} \\[6pt]\text{Dice}_k &= \frac{2\sum_{p} y_p^k \hat{y}_p^k + \epsilon}{\sum_{p} y_p^k + \sum_{p} \hat{y}_p^k + \epsilon}, \quad k \in \{\text{chest}, \text{lung}\} \\[6pt]L_{\text{BCE}} &= -\frac{1}{2N} \sum_{p} \left[ y_p \log \hat{y}_p + (1-y_p) \log(1-\hat{y}_p) \right]\end{aligned}$$
(9)
The Dice coefficient for class \(k\) measures the spatial overlap between prediction and ground truth, with a smoothing factor \(\epsilon =1.0\) ensuring numerical stability. The binary cross-entropy loss is averaged over both classes and all \(N\) pixels.
The Dice loss directly optimizes the region overlap metric and effectively handles class imbalance between chest and lung regions, while cross-entropy provides stable per-pixel gradients. The uncertainty mechanism in Eq. (1) automatically scales the combined segmentation loss relative to other tasks.
-
2.
Lambda (Regularization Parameter) Loss
The regularization parameter λ spans an exponential range (10⁻6 to 10⁻3), covering everything from nearly noise-free images to heavily degraded ones. It is predicted in a normalized log-space. Importantly, the ground-truth λitrue is derived from the NPS-based noise metric of each individual image, which means the network learns to predict λ from image quality, not from acquisition metadata like view count. Let λipred and λitrue denote the predicted and ground-truth values in log-space. The λ prediction is supervised using a combination of mean squared error (MSE) and relative error in log-space:
$${\text{L}}_{\lambda} = \underset{\text{Log-space MSE}}{\underbrace{\frac{1}{\text{N}} \sum_{\text{i}=1}^{\text{N}} \left(\lambda_{\text{i}}^{\text{pred}} – \lambda_{\text{i}}^{\text{true}}\right)^2}} + \eta_{\lambda} \cdot \underset{\text{Relative error in linear space}}{\underbrace{\frac{1}{\text{N}} \sum_{\text{i}=1}^{\text{N}} \frac{\left|\lambda_{\text{i}}^{\text{pred}} – \lambda_{\text{i}}^{\text{true}}\right|}{\left|\lambda_{\text{i}}^{\text{true}}\right| + \epsilon}}}$$
(10-1)
where \({\eta}_{\lambda }=0.2\) balances the two terms, and ε is a small constant for numerical stability. The log-space MSE ensures accurate prediction of the regularization strength across the full exponential range, while the relative error term penalizes large proportional deviations in the linear domain. This composite loss is robust to the inherent variability in NPS-based λ estimates while maintaining sensitivity to systematic prediction errors. The network predicts λ in Z-score.
-
3.
Tissue parameter losses (A1 and A2)
The tissue-specific parameters A₁ (chest) and A₂ (lung) are supervised through a combination of physiological and self-supervised objectives. Let \({A}_{k}^{pred}\) denote the current network prediction, \({A}_{k }^{phys}\) be the fixed physiological target (derived from HU statistics, Section “Evaluation and preprocessing strategy“), and \({A}_{k}^{self}\) be the self-supervised target computed via Eq. (12). The tissue parameter losses are defined as:
$${L}_{{A}_{k}} = \underset{\text{Physiological consistency}}{\underbrace{\frac{1}{2{\sigma}_{k}^{2}}{\Vert {A}_{k}^{\text{pred}} – {A}_{k}^{\text{phys}}\Vert}^{2} + \frac{1}{2}\log{\sigma}_{k}^{2}}} + \eta \cdot \underset{\text{Self-supervised refinement}}{\underbrace{\frac{1}{2{\widetilde{\sigma}}_{k}^{2}}{\Vert {A}_{k}^{\text{pred}} – {A}_{k}^{\text{self}}\Vert}^{2} + \frac{1}{2}\log{\widetilde{\sigma}}_{k}^{2}}} \cdot \omega {L}_{\text{ratio}}$$
(10-2)
where \({\sigma}_{k}^{2}\) and \({\widetilde{\sigma }}_{k}^{2}\) are learned uncertainty parameters controlling the precision of the physiological and self-supervised objectives, respectively. The fixed weight \(\eta \)=0.1 limits the influence of the self-supervised signal, ensuring that the physiologically-grounded target remains the dominant learning objective throughout training. The ratio loss \({L}_{ratio}\) with weight \(\omega \)=0.01 enforces the anatomical constraint \(\frac{{A}_{1}}{{A}_{2}}=1\cdot 19\). This dual-objective formulation eliminates the need for curriculum scheduling or manually tuned blending factors, while the learned uncertainty parameters \({\sigma}_{k}^{2}\) and \({\widetilde{\sigma }}_{k}^{2}\) allow the network to automatically balance the precision of each objective.
Remarks on Loss Weighting: Unlike conventional multi-task learning approaches that require careful manual tuning of loss weights (typically 3–4 additional hyperparameters per task), our framework employs homoscedastic uncertainty weighting where all primary task weights are learned automatically. The network maintains four learnable parameters \({s}_{i}=\text{log}\left(-{\sigma}_{i}\right)\) for the main tasks, initialized to \({s}_{\text{s}\text{e}\text{g}}=0 ,{s}_{\lambda }=0\), \({s}_{{A}_{1}}=0 ,{s}_{{A}_{2}}=0\) which are updated via backpropagation alongside all other network parameters. The effective weight for task i is \({w}_{i}=\text{exp}\left(-{s}_{i}\right)\), with the regularizer \(\frac{1}{2}{s}_{i}\) preventing weights from collapsing to zero. This initialization gives initial task weights of \({w}_{seg }=1 ,{w}_{\lambda }=1 ,{w}_{{A}_{1}}=1 ,{w}_{{A}_{2}}=1\). Two additional uncertainty parameters (\({\widetilde{\sigma }}_{k}^{2}\)) control the self-supervised refinement terms independently. This approach reduces the total number of manually set hyperparameters to exactly 10 (listed in Table 5), eliminating all manual loss balancing coefficients, curriculum scheduling parameters, and gradient normalization factors that are typically required in conventional multi-task frameworks.
Table 5 Training hyperparameters.Dynamic parameter weighting for tissue
For an input batch of CT images \(\text{B}={\left\{{X}_{i},{Y}_{i}\right\}}_{i=1}^{N}\), where \({X}_{i}\in {\text{R}}^{128\times 128}\) is a CT slice, and \({Y}_{i}\in \{\text{0,1}{\}}^{128\times 128\times 2}\) contains ground truth masks for chest/lung, the tissue parameter weights \({A}_{1},{A}_{2}\in [\text{0,1}]\) are computed as:
Step 1: Segmentation Assessment: For each image, the predicted segmentation is thresholded to obtain binary masks: (\({\widehat{M}}_{i}^{(chest) }=\text{I}\left({f}_{\theta }{\left({X}_{i}\right)}^{(chest) }>0\cdot 5\right)\)). The Dice similarity coefficient is computed as:
(\({\text{D}\text{i}\text{c}\text{e}}_{i}^{(chest) }=\frac{2\left|{\hat{M}}_{i}^{(chest) }\cap {Y}_{i}^{(chest) }\right|}{\left|{\hat{M}}_{i}^{(chest) }\right|+\left|{Y}_{i}^{(chest)}\right|}\)), Where \({f}_{\theta }{\left({X}_{i}\right)}\) represents the segmentation prediction function of the neural network, θ denotes the trainable parameters (weights and biases) of the U-Net model across all layers, \({X}_{i}\) is the input CT slice, and \({\text{M}}_{n}\) is the correctly predicted chest region.
Step 2: Intensity Restoration Quality, \({\text{P}\text{S}\text{N}\text{R}}_{i}^{(chest) }=10{\text{log}}_{10}\left(\frac{\text{m}\text{a}\text{x}{\left({X}_{i}\right)}^{2}}{\left.{\text{M}\text{S}\text{E}}_{i}^{(chest)}\right)}\right)\) , and \({\text{M}\text{S}\text{E}}_{i}^{(chest) )}=\frac{1}{\left|{C}_{i}\right|}{\sum}_{p\in {C}_{i}} {\left({X}_{i}(p)-{\mu}_{i}^{(chest) }\right)}^{2}\), where \({C}_{i}={\mathcal{M}}_{i}^{(chest) }\cap {Y}_{i}^{(chest)}\) (correctly predicted chest pixels) and \({\mu}_{i}^{(chest)}\) is the mean intensity in \({C}_{i}\).
Step 3: Edge Sharpness Metric50.
$${E}_{i}^{(chest) }= \frac{1}{\left|\partial {\hat{M}}_{i}^{(chest) }\right|}\sum_{p\in {\hat{M}}_{i}^{chest) }} {\Vert \nabla {X}_{i}(p)\Vert }_{2}, {\Vert \nabla {X}_{i}(p)\Vert }_{2}=\sqrt{{G}_{x}(p{)}^{2}+{G}_{y}(p{)}^{2}}$$
(11)
where \(\partial {\hat{M}}_{i}^{(chest)}\) denotes the boundary pixels of the predicted mask (extracted via morphological perimeter detection), and \({G}_{x}\),\({G}_{y}\) are the Sobel filter outputs. The edge sharpness is normalized to [0,1] by dividing by 100 and clamping.
Step 4: Composite Score: The self-supervised target for A₁ is computed as a weighted combination:
$${A}_{1}^{self}=\frac{1}{N}\sum_{n=1}^{N} (0\cdot 5\cdot {Dice}_{i}^{chest}+0\cdot 3\cdot \frac{{PSNR}_{i}^{chest}}{50}+0\cdot 2\cdot \frac{{E}_{i}^{chest}}{100}$$
(12)
The final score is clipped to [0.1,1.0] to ensure numerical stability. The self-supervised target for lung tissue (A₂) is computed analogously using the lung-specific masks and regions.
The weights (50%, 30%, 20%) are explicitly defined in Eq. (12) and reflect the relative importance of anatomical accuracy, intensity fidelity, and boundary sharpness in determining tissue-specific regularization parameters.
By coupling segmentation quality with intensity and edge information, the resulting targets A₁ and A₂ serve as region-dependent confidence measures that guide the SvRTV regularizer to enforce structural consistency while preserving visual fidelity in the reconstructed CT slices.
Stopping criteria for training
Training was terminated when all of the following conditions were simultaneously satisfied for at least 3 consecutive epochs: (1) mean Dice coefficient > 0.93 for chest and > 0.90 for lung, (2) Hausdorff Distance < 5.0 pixels for chest and < 5.0 pixels for lung, (3) Lambda relative error < 0.50, and (4) absolute.
variations of estimated parameters A₁ and A₂ below 0.08. A minimum of 50 epochs was enforced before early stopping could activate. Additionally, training was terminated if validation loss did not improve for 40 consecutive epochs after epoch 50.
Implementation details
We employed the Adam optimizer with parameters β1 = 0.9, β2 = 0.999, and ε = 10⁻⁸, using an initial learning rate of 1 × 10⁻3. A cosine warmup schedule was applied for the first 5 epochs, followed by step decay where the learning rate was multiplied by a factor of 0.3 every 30 epochs. The model was trained with a batch size of 8 for up to 100 epochs, with the first 50 epochs dedicated to segmentation-only training (Phase 1) and the remaining 50 epochs incorporating all four tasks (Phase 2). Gradient clipping with a global norm threshold of 2.0 was applied, with additional per-layer clipping of 5.0 for convolutional layers and 2.0 for fully-connected layers. The four uncertainty parameters \({s}_{i}\) were initialized to [1, 1, 1, 1] and updated via Adam alongside the network weights. Data augmentation included random horizontal and vertical reflections, random rotation (± 8°), random translation (± 8 pixels), random scaling (0.92–1.08), and Gaussian noise (σ = 0.02) applied with 30% probability. Early stopping was governed by the multi-criteria stopping rule described in Section “Stopping criteria for training“. A comprehensive summary of all training hyperparameters is provided in Table 5.