Experimentally, we obtain driving pulses in the green spectral region (516 nm) by second-harmonic generation from a ytterbium-based laser system. Subsequent spectral broadening in a gas-filled multipass cell and compression with dispersive mirrors yield a pulse duration below 20 fs. The high-harmonic generation scheme is illustrated in Fig. 1a; a detailed description of the experimental setup and procedures is provided in the Methods and Supplementary Note 1. Ultrashort green pulses are focused to a vacuum focal intensity about six times the conventional phase-matching limit of approximately 0.75 PW cm−2 at the pulse peak31. The helium target is positioned in front of the geometrical focus, at approximately 0.8 Rayleigh lengths.

Fig. 1: High-flux high-harmonic generation in the extreme ultraviolet.This figure presents experimental and simulated data on high harmonic generation using a 516 nanometer laser pulse with 18 femtosecond duration and 360 microjoule energy. Panel a illustrates the experimental setup: a laser pulse passes through helium gas and a zirconium filter, producing an extreme ultraviolet beam that is dispersed by a grating and detected by an XUV camera. An inset graph shows the input and output spectral power in decibels across wavelengths from 450 to 550 nanometers. Panel b compares measured and simulated flux of high harmonics labeled HH33, HH35, HH37, and HH39 as a function of photon energy from 80 to 98 electronvolts, with experimental data showing distinct peaks at these harmonics and simulations represented by shaded areas. Panel c shows normalized flux of the HH37 harmonic versus backing pressure from 6 to 15 bar, with experimental points and simulation curve indicating a peak flux near 11 bar; a secondary horizontal axis indicates corresponding particle density ranging from 4 to 8 times ten to the nineteenth per cubic centimeter.

a Experimental scheme showing the retrieved driving-pulse profile and laser input parameters, the helium (He) gas jet in the interaction region, and the downstream XUV diagnostics. Zirconium (Zr) filters remove residual laser radiation and attenuate the XUV signal, while a grating disperses the harmonics for spectral characterization. Insets show the measured driving-laser spectrum before and after the nonlinear interaction, the recorded XUV beam profile after 1.4 m of propagation, and the diffracted harmonic orders on the XUV camera. b Measured XUV spectrum (Exp.) together with the corresponding simulation results (Sim.). The qth high harmonic is denoted HHq. The dashed lines delimit the lithography-relevant 2% bandwidth (BW) centered at 13.5 nm. The simulated spectrum is normalized to the experimental data at HH37. c Photon flux of HH37 versus backing pressure, compared with simulations as a function of the effective particle density in the interaction region. The simulated density is reduced relative to the backing-pressure estimate by the constant correction factor described in the “Methods”.

In this configuration, we observe bright high-harmonic emission up to 100 eV, with a near-Gaussian spatial profile (inset of Fig. 1a) and a divergence half-angle of 0.8 mrad (1/e2). At 13.5 nm (91.8 eV), the XUV flux exceeds 1011 ph s−1 eV−1 (Fig. 1b). For HH37, we obtain 2.7 μW within a 2% bandwidth (ΔE/E) centered at 13.5 nm, corresponding to the in-band spectral window relevant for EUV lithography32. This exceeds previous results by more than an order of magnitude33,34. The lower-energy HH33 reaches an even higher power of 7.3 μW over its full spectral linewidth, corresponding to a conversion efficiency of 10−6.

HH37 is located at 13.5 nm, even though for a 516 nm driver conventional HHG would place it at 88.9 eV rather than 91.8 eV. The measured driving-laser spectrum after the nonlinear interaction indeed exhibits a pronounced blueshift (Fig. 1a), indicating a strong laser-plasma interaction. Through high-harmonic generation, this spectral blueshift is multiplied by the harmonic order, amounting to almost 3 eV for HH37.

To analyze the plasma dynamics underlying both the observed spectral shift and the high-flux emission, we model the nonlinear interaction, including the evolution of the driving laser field, the single-atom dipole response of helium, and the coherent buildup of the XUV radiation (see “Methods” for details). The simulations closely reproduce the measured spectral shape and harmonic positions (Fig. 1b) and also capture the pressure dependence of the harmonic yield, shown for HH37 in Fig. 1c.

We first turn to the evolution of the driving laser field by comparing vacuum propagation with propagation through the helium target (Fig. 2a). In vacuum, the highest on-axis laser intensity would exceed 4 PW cm−2 at the focus (z = 0 mm). With the helium target present, plasma formation sets in immediately as the beam enters the gas, and the resulting plasma-induced defocusing limits the maximum on-axis intensity to approximately 2 PW cm−2. The corresponding radial peak-intensity distribution (Fig. 2b) reveals a transversely flattened high-intensity region that persists over an extended propagation distance. This characteristic intensity stabilization identifies the propagation as plasma-core-induced self-guiding30.

Fig. 2: Evolution of the driving-pulse intensity.The image presents data on laser pulse intensity and particle density in a helium environment compared to vacuum. Panel a shows intensity versus position along the z-axis, with two curves: one for vacuum and one with helium, alongside a shaded area representing helium particle density. Three specific positions along z, labeled z1 at minus 1.30 millimeters, z2 at minus 0.97 millimeters, and z3 at minus 0.62 millimeters, are marked within the helium distribution. Panel b displays a three-dimensional plot of intensity as a function of radial position r and axial position z, with a white line indicating a specific intensity profile. Panel c provides three time-resolved intensity maps at the three marked z positions, showing intensity as a function of radial position r and time in femtoseconds, with intensity values indicated by a color scale.

a On-axis peak intensity of the driving pulse in vacuum and in the presence of the helium gas target. The vacuum focus is at z = 0 mm; the vacuum Rayleigh length zR is marked, and the shaded profile shows the gas particle density on the right-hand axis. b Peak-intensity distribution of the driving pulse as a function of radial position r and propagation position z in the helium gas target. The white contour encloses the region in which the peak intensity exceeds 0.75 PW cm−2. The color scale is identical to that used in the left panel of (c). c Spatio-temporal intensity-envelope distributions of the driving pulse in a co-moving frame at the three propagation positions indicated in (a).

The spatio-temporal evolution of the driving laser field is visualized in Fig. 2c at three positions along the propagation direction. At z1, before the gas target, the pulse is unperturbed. Upon entering the target, the strongly nonlinear ionization response produces a steep plasma gradient across the beam. The resulting stronger plasma-induced phase advance on axis than off axis curves the intensity distribution in space and time, forming a crescent-shaped profile at z2. The same time-dependent plasma phase drives the pronounced spectral blueshift during the initial propagation through the gas target. This is followed by an extended self-regulated propagation regime, in which the intensity distribution near the optical axis and the spectrum evolve only weakly. The near-axis spatio-temporal profile therefore remains largely preserved at z3. Sustaining the stabilized propagation over an extended distance requires placing the gas target in front of the geometrical focus, so that the converging beam is balanced by the diverging plasma lens, which flattens the wavefront29. This effect is maximized about one Rayleigh length from the focus, where the wavefront curvature is largest.

Within this self-regulated regime, we observe a stabilized intensity of approximately 0.9 PW cm−2, on the scale of the barrier-suppression intensity of helium35. Previous simulations found the regulated intensity to be determined predominantly by the gas species, with only weak sensitivity to other propagation conditions30. Our simulations confirm that the driving wavelength alone has little influence on the stabilized propagation. A clear wavelength dependence emerges, however, under phase-matched HHG conditions. The pressure required for phase matching scales approximately as pPM ∝ λ236, such that longer driving wavelengths require higher gas pressures. The associated increase in particle density produces stronger plasma defocusing and lowers the self-stabilized intensity without disrupting the stabilized propagation (see Supplementary Note 4).

Notably, the ionization fraction selected by this self-regulation shifts in the same direction as the critical ionization for phase matching, which decreases toward longer driving wavelengths (ηcr ∝ λ−237). This behavior is consistent with the observation of Tosa et al. that the ionization established within the channel sets the propagated field intensity29. Plasma-core guiding therefore naturally supports ionization conditions compatible with phase-matched HHG, with shorter driving wavelengths establishing these conditions at higher regulated intensities and thereby favoring higher conversion efficiency.

To assess the phase-matching mechanism in the stabilized propagation regime, we analyze the local buildup conditions for HH37, corresponding to the experimentally relevant spectral region around 13.5 nm. The phase mismatch can be calculated directly from the simulated fields by subtracting the phase accumulated by the propagated XUV field from the phase of the dipole source term. This definition includes the full phase evolution of the reshaped driving laser, including atomic, plasma and geometric contributions, as well as the intrinsic dipole phase associated with the electron excursion in the continuum. In the initial part of the gas target, where the driver undergoes rapid intensity reduction and a strong blueshift, the dipole amplitude is strongly modulated, and no extended region of long coherence length (Lcoh) is formed (Fig. 3a). Once the driving field enters the stabilized regime, the dipole emission becomes nearly stationary. In the central part of the target, this emission region overlaps with a region of long coherence length, showing that the stabilized driver and the nearly constant gas density jointly provide favorable conditions for phase-matched macroscopic buildup. Toward the end of the gas target, the coherence length decreases again while the dipole amplitude remains comparatively stable. We attribute this to the decreasing gas density at the target boundary, which changes the local phase-matching condition although the driving field remains stabilized. The resulting macroscopic buildup confirms this interpretation: the HH37 flux grows monotonically throughout the stabilized propagation region, corresponding to approximately two absorption lengths (Fig. 3b). For the peak particle density of 6.2 × 1019 cm−3, the corresponding absorption length is 308 μm. This behavior indicates operation close to the absorption-limited regime20.

Fig. 3: Macroscopic high-harmonic generation dynamics.The image presents data on the behavior of HH37 flux and related parameters during a propagation process. Panel a shows emission amplitude and coherence length as functions of radial position and propagation distance, with a white curve marking a boundary. Panel b plots normalized HH37 flux increasing with propagation distance, reaching a plateau near three absorption lengths, with three vertical lines labeled Z1, Z2, and Z3 marking specific distances. Panel c shows normalized HH37 power peaking sharply around -12 femtoseconds, while ionization fraction rises steadily over time, crossing a critical ionization threshold. Panel d contains two graphs: the top graph shows HH37 flux increasing with pulse energy up to a maximum point, then slightly decreasing, while the center of mass of HH37 shifts upward continuously; the bottom graph shows HH37 efficiency peaking at a lower pulse energy than the flux maximum and then declining. The vertical dashed lines in panel d indicate the pulse energies corresponding to maximum flux and maximum efficiency.

a Dipole-amplitude and coherence-length Lcoh distributions at the spectral peak of the 37th harmonic (HH37) as functions of radial position r and propagation position z. The coherence length is given in units of the absorption length Labs. The white contour encloses the region in which the peak driving-laser intensity exceeds 0.75 PW cm−2. For visualization, the coherence length is set to zero outside this contour, where no appreciable dipole amplitude is present. b Coherent buildup of HH37 along the gas target (shaded region), with the propagation distance given in units of Labs for a helium particle density of 6.2 × 1019 cm−3. The three indicated z positions correspond to those marked in Fig. 2a. c Temporal profile of the spectrally filtered HH37 at the end of the gas target and the corresponding ionization fraction spatially averaged over the coherent emission volume identified in (a). The dashed line indicates the critical ionization fraction (ηcrit). d Spectral position and normalized flux of HH37 as functions of the driving-laser input energy in the upper panel, and the corresponding conversion efficiency from the driving laser to HH37 in the lower panel. The dotted line marks the input energy at which the conversion efficiency reaches its maximum (\({{{{\rm{Eff}}}}}_{\max }\)), while the dashed line marks the experimental input energy (\({E}_{\exp }\)), which coincides with the maximum-flux operating point (\({F}_{\max }\)).

The simulated temporal structure of this phase-matched emission is shown in Fig. 3 c for the spectrally filtered HH37 signal. The emission is centered around t = −12 fs, close to the peak of the reshaped driving-pulse envelope (Fig. 2b). At this time, the ionization fraction reaches the critical ionization fraction of approximately 1.2%, expected from the balance of neutral and plasma dispersion. Together with the stabilized intensity discussed above, this shows that the generation conditions are consistent with the conventional strong-field phase-matching picture31,37,38. Although the pulse initially reaches intensities well above the barrier-suppression intensity and undergoes strong plasma-induced reshaping, the subsequent self-regulated propagation recovers conditions for conventional phase-matched HHG. The harmonic buildup is therefore governed predominantly by neutral and plasma dispersion, with only a minor contribution from the intrinsic dipole phase. The spectrally filtered HH37 emission has a full width at half maximum of about 3 fs, with the phase-matched generation window spanning only a few optical cycles of the driver.

The plasma-mediated reshaping discussed above also determines the spectral position of the emitted harmonics through the blueshift imparted to the driving pulse. We examine this dependence by varying only the input pulse energy in the simulations while keeping all other parameters unchanged. Figure 3d shows the photon flux, spectral position and conversion efficiency of HH37 as functions of the input pulse energy. Increasing the pulse energy continuously shifts HH37 toward higher photon energies, while its photon flux remains high across the investigated range. The propagation analysis above identifies the initial propagation through the gas target as the stage of strongest laser-plasma interaction and field reshaping, whereas the harmonic buildup occurs predominantly during the subsequent self-regulated propagation. Spectral tuning through ionization-induced blueshifts was previously observed by varying the gas-target position relative to the laser focus39, while numerical simulations by Gaarde et al. showed that frequency modulation and dominant harmonic generation can occur in spatially separated regions40. In the present self-guided regime, this separation enables the harmonic photon energy to be tuned by varying the input pulse energy while largely preserving the generated flux. Notably, for a 516 nm driver, the HH37 flux is maximized at the pulse energy for which the harmonic is centered at 13.5 nm.

The lower panel of Fig. 3d shows that the conversion efficiency reaches its maximum at a lower pulse energy. In Supplementary Note 5, we compare the maximum-efficiency and maximum-flux points directly. Despite the difference in pulse energy, both cases exhibit essentially the same phase-matched harmonic buildup and few-femtosecond emission window, showing that the generation dynamics are robust across a broad range of input energies during self-regulated propagation. The main differences originate during the initial reshaping stage, where the laser-plasma interaction is strongest. At reduced pulse energy, the high-intensity region overlaps more closely with the coherently emitting volume. At higher energies, plasma-lens-induced defocusing redirects more energy into the surrounding crescent-shaped profile, where it contributes little to the coherent macroscopic buildup. The higher conversion efficiency therefore reflects improved spatial overlap rather than a change in the underlying harmonic-emission dynamics.

Finally, we consider the influence of the driving-pulse duration. Within the conventional strong-field phase-matching picture, shorter pulses support phase matching at higher intensities because reaching a given ionization fraction over a shorter pulse requires a higher intensity31. For the same reason, the self-stabilized intensity shifts to a higher value as the pulse duration is reduced. The self-stabilized intensity and the phase-matching condition therefore remain naturally aligned as both shift toward higher intensities. In our simulations, reducing the driving-pulse duration to 10 fs increases the self-stabilized intensity by about 10%. This extends the emission beyond 100 eV and increases the HH37 conversion efficiency by approximately a factor of two.

Taken together, these results demonstrate that the long-recognized efficiency advantage of visible-wavelength drivers can be translated into high-flux HHG at high XUV photon energies. Experimentally, the demonstrated source performance sets a flux benchmark in this spectral range. Our experiments and numerical analysis establish a general design principle for realizing this advantage in a plasma-core-induced self-guiding regime, where sustained high intensity and favorable phase matching allow extended macroscopic buildup.

The immediate implication of this high coherent XUV flux is to extend the capabilities of signal-limited applications, opening access to measurements that would otherwise be constrained by photon statistics in high-throughput spectroscopy, coincidence microscopy and coherent imaging. Bright emission around 13.5 nm is particularly relevant for laboratory-scale actinic metrology. More broadly, the source combines these favorable generation dynamics with frequency-doubled ytterbium technology, for which laser systems, frequency conversion and pulse compression have already been demonstrated at substantially higher average powers41,42,43,44,45. This provides a realistic pathway toward laboratory-scale coherent XUV sources with photon fluxes approaching those currently associated with large-scale infrastructures.